technical data
Working Pressure Range
Maximum Working
Temperature
Flow Rate
Inlet Connection
Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500.
Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government
regulations when considering the choice of, and the installation of these products.
This product must be installed and commissioned by a qualified plumber.
For use with potable water only.
NOTE: Enware Australia advises:
1. Due to ongoing Research and Development, specifications may change without notice.
2. Component specifications may change on some export models.
I00582_09 Feb 2024
1300 369 273 | info@enware.com.au | enware.com.au
Min 50 kPa
Max 500 kPa
70°C
6 L/min (WELS 5 Star)
3.5 L/min (WELS 6 Star)
1/2" BSP (15mm)

Advertisement

loading
Need help?

Need help?

Do you have a question about the ENWARE SPC001 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Watts ENWARE SPC001

  • Page 1 Cache Hob Mounted Curved Basin Spout Installation and Maintenance Instructions SPC001 technical data Working Pressure Range Min 50 kPa Max 500 kPa Maximum Working 70°C Temperature Flow Rate 6 L/min (WELS 5 Star) 3.5 L/min (WELS 6 Star) Inlet Connection 1/2”...
  • Page 2 installation 22 - 25 • Ensure all supply lines are flushed thoroughly to remove debris prior to the installation of this product. Strainers (40 mesh) are recommended if debris is an ongoing problem. • A pressure reduction valve may be required to comply with IMAGE 01 INSTALLATION DETAIL the recommended maximum supply pressure requirements.
  • Page 3 maintenance CLEANING Enware products should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals. Do not use cream cleaners, as they are abrasive. Use of unsuitable cleaning agents may damage the surface.
  • Page 4 - WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...