Download Print this page
Matco Tools SE8013 Operating Instructions Manual
Matco Tools SE8013 Operating Instructions Manual

Matco Tools SE8013 Operating Instructions Manual

Full size spray gun with 1.3mm tip, with 1.4mm tip

Advertisement

Quick Links

Operating Instructions • Warning Information • Parts Breakdown
SE8013–SPECIFICATIONS
Fluid Orifice: ..........................................................1.3mm
Air inlet: .............................................................. 1/4" NPT
Rec. max. inlet air pressure:..................................... 60psi
CFM:...............................................................10.1 at 60psi
Nozzle pressure: ....................................................... 47psi
Cup size: ....................................................................600cc
SE8014–SPECIFICATIONS
Fluid Orifice: ..........................................................1.4mm
Air inlet: .............................................................. 1/4" NPT
Rec. max. inlet air pressure:..................................... 60psi
CFM:...............................................................10.1 at 60psi
Nozzle pressure: ....................................................... 47psi
Cup size: ....................................................................600cc
SE8013/14_OpMan051605.indd 1
SE8013
F
S
ULL
IZE
WITH
SE8014
F
S
ULL
IZE
WITH
1
S
G
PRAY
UN
1.3
MM TIP
S
G
PRAY
UN
1.4
MM TIP
Rev. 05/16/05
5/16/05 4:39:14 PM

Advertisement

loading
Need help?

Need help?

Do you have a question about the SE8013 and is the answer not in the manual?

Questions and answers

Summary of Contents for Matco Tools SE8013

  • Page 1 PRAY Fluid Orifice: ............1.4mm WITH MM TIP Air inlet: .............. 1/4" NPT SE8014 Rec. max. inlet air pressure:........60psi CFM:...............10.1 at 60psi PRAY Nozzle pressure: ............47psi Cup size: ..............600cc WITH MM TIP Rev. 05/16/05 SE8013/14_OpMan051605.indd 1 5/16/05 4:39:14 PM...
  • Page 2 • High sound levels can cause permanent materials. The mask must be compatible with the hearing loss. Protect yourself from material being sprayed and its concentration. noise. Noise levels vary with work Rev. 05/16/05 SE8013/14_OpMan051605.indd 2 5/16/05 4:39:16 PM...
  • Page 3 Air pressure for atomization is regulated at extractor. Amount of fluid is adjusted Air Inlet by fluid control screw on gun, viscosity of paint, and air pressure. Oil and Water Extractor Air Hose Rev. 05/16/05 SE8013/14_OpMan051605.indd 3 5/16/05 4:39:17 PM...
  • Page 4 If the spray is too thick, the surface being finished. close the fluid control screw. Regulate the pattern width and repeat adjustment of spray as needed. Spray pattern may be infinitely adjusted from round to flat. Rev. 05/16/05 SE8013/14_OpMan051605.indd 4 5/16/05 4:39:17 PM...
  • Page 5 If the parts can not easily be turned by hand , be sure you have the correct parts, Fig. 1 unscrew, realign, and try again. NEVER use excessive force in matching parts. Rev. 05/16/05 SE8013/14_OpMan051605.indd 5 5/16/05 4:39:18 PM...
  • Page 6 A.) Move gun closer to surface. Thin, sandy coarse finish. B.) Atomization pressure set B.) Adjust atomization pressure. too high. Thick, dimpled finish Gun held too close to surface. Move gun further from surface. resembling orange peel. Rev. 05/16/05 SE8013/14_OpMan051605.indd 6 5/16/05 4:39:19 PM...
  • Page 7 PARTS BREAKDOWN - SE8013 and SE8014 �� �� �� � � � � � � � � � �� �� �� �� �� �� �� ��� � �� �� �� �� �� �� �� �� �� �� �� �� Rev. 05/16/05 SE8013/14_OpMan051605.indd 7...
  • Page 8 PARTS LIST - SE8013 AND SE8014 REF# ITEM NO. DESCRIPTION WARRANTY RS1701-1.3A Air cap for SE8013 (1.3mm) - green RS1701A Air cap for SE8014 (1.4mm) - blue Matco warrants its air tools for a period of 1 RS1704-1.3 Fluid nozzle for SE8013 (1.3mm) year to the consumer.