System Configuration; Power Down - Dell POWEREDGE R515 Hardware User Manual

Dell computer hardware user manual
Hide thumbs Also See for DELL POWEREDGE R515:
Table of Contents

Advertisement

Message
Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.
Alert! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Alert!
Continuing
system boot
accepts the risk
that system may

power down

without warning.
Alert! System
fatal error
during previous
boot.
Causes
The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a memory
module has failed) so that
node interleaving cannot be
supported. The system still
runs, but without node
interleaving.
The system configuration
of processor(s),
memory modules,
and expansion cards may
not be supported by the
power supplies.
An error caused the
system to reboot.
Corrective Actions
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving.
Check other system
messages for additional
information for possible
causes. For memory
configuration information,
see "General Memory
Module
Installation Guidelines" on
page 105. If the problem
persists,
see "Troubleshooting System
Memory" on page 165.
If any system components
were just upgraded,
return the system to the
previous configuration.
If the system boots without
this warning, then the
replaced component(s) are
not supported with this
power supply. If Energy
Smart power supplies are
installed, replace them with
High Output power supplies
to use the components.
See "Power Supplies" on
page 102.
Check other system
messages for additional
information for possible
causes.