Dell POWEREDGE R515 Hardware User Manual page 30

Dell computer hardware user manual
Hide thumbs Also See for DELL POWEREDGE R515:
Table of Contents

Advertisement

Code
Text
E1410
System Fatal
Error
detected.
E1414
CPU # temp
exceeding
range.
Check CPU
heatsink.
E1418
CPU # not
detected.
Check CPU
is seated
properly.
E141C
Unsupported
CPU config.
Check CPU or
BIOS revision.
E141F
CPU # protocol
error. Power
cycle AC.
30
About Your System
Causes
Specified processor has an
internal error. The error
may or may not have
been caused by
the processor.
Specified processor is out
of acceptable
temperature range.
Specified processor is
missing or bad,
and the system is in an
unsupported
configuration.
Processors are in an
unsupported
configuration.
The system BIOS
has reported a processor
protocol error.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 187.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting
Processors" on page 174
and "Troubleshooting
System Cooling
Problems" on page 163.
Ensure that the specified
processor is properly
installed. See
"Troubleshooting
Processors" on page 174.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system's
Getting Started Guide.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 187.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents