Dell POWEREDGE R515 Hardware User Manual page 29

Dell computer hardware user manual
Hide thumbs Also See for DELL POWEREDGE R515:
Table of Contents

Advertisement

Code
Text
E122A
CPU # VTT
Regulator
failure.
Reseat CPU.
E122C
CPU Power
Fault. Power
cycle AC.
E122D
Memory
Regulator #
Failed.
Reseat DIMMs.
E122E
On-board
regulator
failed.
Call support.
E1310
Fan ## RPM
exceeding
range.
Check fan.
E1313
Fan redundancy
lost.
Check fans.
Causes
Specified processor
VTT voltage regulator
has failed.
A power fault was
detected when powering
up the processor(s).
One of the memory
regulators has failed.
One of the on-board
voltage regulators has
failed.
RPM of specified fan is
outside of the intended
operating range.
The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
overheating.
Corrective Actions
Reseat the processor(s).
See "Troubleshooting
Processors" on page 174.
If the problem persists,
see "Getting Help" on
page 187.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 187.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 165.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 187.
See "Troubleshooting
System Cooling
Problems" on page 163.
Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan"
on page 164.
About Your System
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents