System Messages - Dell POWEREDGE R515 Hardware User Manual

Dell computer hardware user manual
Hide thumbs Also See for DELL POWEREDGE R515:
Table of Contents

Advertisement

Any of these actions will remove fault messages, and return the status
indicators and LCD colors to the normal state. Messages will reappear under
the following conditions:
The sensor returns to a normal state but fails again, resulting in
a new SEL entry.
The system is reset and new error events are detected.
A failure is recorded from another source that maps to the
same display entry.

System Messages

System messages appear on the screen to notify you of a possible problem
with the system.
NOTE:
If you receive a system message not listed in the table, check the
documentation for the application that is running or the operating system's
documentation for an explanation of the message and recommended action.
Message
Alert! iDRAC6 not
responding.
Rebooting.
Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
40
About Your System
Causes
The optional iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization.
The system reboots.
The optional iDRAC6
has hung.
The optional iDRAC6 was
remotely reset while
system was booting.
After AC recovery, the
optional iDRAC6 takes
longer than normal to boot.
Corrective Actions
Wait for the system
to reboot.
Remove AC power to the
system for 10 seconds and
restart the system.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents