Installer reference guide
Daikin room air conditioner

Advertisement

loading
Need help?

Need help?

Do you have a question about the FTXF60F2V1B and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FTXF60F2V1B

  • Page 1 Installer reference guide Daikin room air conditioner FTXP50N2V1B FTXP60N2V1B FTXP71N2V1B FTXF60F2V1B FTXF71F2V1B ATXF60F2V1B ATXF71F2V1B...
  • Page 2 To pass the pipes through the wall hole........................To fix the unit on the mounting plate..........................Closing the unit................................9.4.1 To close the electrical wiring box cover ......................Installer reference guide FTXF-F, ATXF-F, FTXP-N Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 3 To perform a test run in winter season......................13 Hand-over to the user 14 Disposal 15 Technical data 15.1 Wiring diagram ................................15.1.1 Unified wiring diagram legend ........................16 Glossary FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 4 WARNING Make sure installation, servicing, maintenance, repair and applied materials follow the instructions from Daikin (including all documents listed in “Documentation set”) and, in addition, comply with applicable legislation and are performed by qualified persons only. In Europe and areas where IEC standards apply, EN/IEC 60335-2-40 is the applicable standard.
  • Page 5 A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of the latest technical data is available on the Daikin Business Portal (authentication required). 1.1.1 Meaning of warnings and symbols DANGER Indicates a situation that results in death or serious injury.
  • Page 6 Example: " 1–3 Figure title" means "Figure 3 in chapter 1". Indicates a table title or a reference to it. Example: " 1–3 Table title" means "Table 3 in chapter 1". FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 7 WARNING Improper installation or attachment of equipment or accessories could result in electrical shock, short-circuit, leaks, fire or other damage to the equipment. ONLY use accessories, optional equipment and spare parts made or approved by Daikin unless otherwise specified. WARNING Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation).
  • Page 8 WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation (for example national gas regulation) and are executed ONLY by authorised persons. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U –...
  • Page 9 Keep the pipework installation to a minimum. To determine the minimum floor area 1 Determine the total refrigerant charge in the system (=  factory refrigerant charge additional refrigerant amount charged). FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 10 Total refrigerant charge in the system Minimum floor area (a) Ceiling-mounted unit (= Ceiling-mounted unit) (b) Wall-mounted unit (= Wall-mounted unit) (c) Floor-standing unit (= Floor-standing unit) FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 11 Make sure refrigerant piping installation complies with applicable legislation. In Europe, EN378 is the applicable standard. NOTICE Make sure the field piping and connections are NOT subjected to stress. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 12 If NOT factory installed, a main switch or other means for disconnection, having a contact separation in all poles providing full disconnection under overvoltage category III condition, MUST be installed in the fixed wiring. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 13 Use an appropriate screwdriver for tightening the terminal screws. A screwdriver with a small head will damage the head and make proper tightening impossible. ▪ Over-tightening the terminal screws may break them. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 14 ON and OFF while the product is operating, attach a reversed phase protection circuit locally. Running the product in reversed phase can break the compressor and other parts. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 15 Use flare nuts that are included with the unit. Using different flare nuts may cause refrigerant gas leakage. "8 Electrical installation" [  36]) Electrical installation (see DANGER: RISK OF ELECTROCUTION WARNING ALWAYS use multicore cable for power supply cables. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 16 This could result in electrical shock or fire. WARNING Keep the interconnection wiring away from copper pipes without thermal insulation as such pipes will be very hot. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 17 ▪ the mounting plate attached to the back of the indoor unit. 1× 1× 1× 1× 1× 2× 2× 2× 1× 1× FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 18 "9.3 To fix the unit on the mounting plate" [  43]. f Dry battery AAA.LR03 (alkaline) for user interface g User interface holder h User interface i Mounting plate j Wireless LAN adapter FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 19 A safety device might stop the operation of the system if the unit runs outside its operation range. Condensation and water dripping might occur if the unit runs outside its operation range. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 20 A safety device might stop the operation of the system if the unit runs outside its operation range. Condensation and water dripping might occur if the unit runs outside its operation range. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 21 Wall insulation. When conditions in the wall exceed 30°C and a relative humidity of 80%, or when fresh air is inducted into the wall, then additional insulation is required (minimum 10 mm thickness, polyethylene foam). FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 22 ≥50 (mm) 6.2 Opening the unit 6.2.1 To remove the front panel 1 Hold the front panel by the panel tabs on both sides and open it. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 23 1 Remove the front panel to remove the air filter. 2 Remove 3 screws from the front grille. 3 Push down the 3 upper hooks marked with a symbol with 3 circles. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 24 6.3 Mounting the indoor unit In this chapter 6.3.1 To install the mounting plate..........................6.3.2 To drill a wall hole ..............................6.3.3 To remove the pipe port cover..........................FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 25 1 Drill a 80  mm large feed-through hole in the wall with a downward slope towards the outside. 2 Insert a wall embedded pipe into the hole. 3 Insert a wall cover into the wall pipe. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 26 To connect the piping on left side, left-back, or left-bottom ................6.4.4 To check for water leaks ............................6.4.1 General guidelines ▪ Pipe length. Keep drain piping as short as possible. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 27 1 Insert the drain hose in the drain pipe as shown in the following figure, so it will NOT be pulled out of the drain pipe. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 28 4 mm hexagonal wrench 3 Insert the drain hose on the left side and do not forget to tighten it with the fixing screw; otherwise water leakage may occur. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 29 6.4.4 To check for water leaks 1 Remove the air filters. 2 Gradually pour approximately 1  l of water in the drain pan, and check for water leaks. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 30 Depending on the applicable legislation and the maximum working pressure of the unit (see "PS High" on the unit name plate), larger piping thickness might be required. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 31 7.2.2 Precautions when connecting the refrigerant piping INFORMATION Also read the precautions and requirements in the following chapters: ▪ "2 General safety precautions" [  7] ▪ "7.1 Preparing refrigerant piping" [  30] DANGER: RISK OF BURNING/SCALDING FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 32 ▪ Coat the flare inner surface with ether oil or ester oil when connecting a flare nut. Tighten 3 or 4 turns by hand, before tightening firmly. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 33 4 Flare the pipe. Set exactly at the position as shown in the following figure. Flare tool for R32 Conventional flare tool (clutch type) Clutch type Wing nut type (Ridgid-type) (Imperial-type) 0~0.5 mm 1.0~1.5 mm 1.5~2.0 mm FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 34 1 Use a leakage test method with a minimum sensitivity of 5 g of refrigerant/ year. Test leaks using a pressure of at least 0.25 times the maximum working pressure (see "PS High" on the unit nameplate). FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 35 Piping installation If a leak is detected 1 Recover the refrigerant, repair the joint, and repeat the test. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 36 ALWAYS use multicore cable for power supply cables. INFORMATION Also read the precautions and requirements in the "2  General safety precautions" [  7]. INFORMATION Also read "8.1.3 Specifications of standard wiring components" [  39]. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 37 To prepare stranded conductor wire for installation Method 1: Twisting conductor 1 Strip insulation (20 mm) from the wires. 2 Slightly twist the end of the conductor to create a "solid-like" connection. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 38 Tightening torques Item Tightening torque (N•m) M4 (X1M) M4 (earth) ▪ The earth wire between the wire retainer and the terminal must be longer than the other wires. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 39 Note: In case the interconnection cable was stripped in advance, cover the ends with insulating tape. 3 Bend the end of the cable up. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 40 2 Remove the wireless LAN adapter cable from the S21 connector. 3 Connect other optional accessory to the S21 connector and lead the wire harness as shown in the following figure. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 41 S21 wire harness routing for other optional accessory c S21 connector 4 Close the electrical wiring box; see "9.4.1  To close the electrical wiring box cover" [  43]. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 42 1 Shape the refrigerant pipes along the pipe path marking on the mounting plate. a Drain hose b Caulk this hole with putty or caulking material c Adhesive vinyl tape d Insulation tape e Mounting plate (accessory) FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 43 1 Install the front grille and firmly engage the 3 upper hooks. 2 Install 3 screws back on the front grille. 3 Install the air filter and then mount the front panel. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 44 1 Attach the front panel. Align the shafts with the slots and push them all the way in. 2 Close the front panel slowly; press at both sides and at the centre. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 45 INFORMATION: Declaration of conformity ▪ Daikin Industries Czech Republic s.r.o. declares that the radio equipment type inside of this unit is in compliance with Directive 2014/53/EU. ▪ This unit is considered as combined equipment according to the definition of Directive 2014/53/EU.
  • Page 46 5 Snap the top of the upper case into the clip at the top of the lower case and press to close the box. 6 Fix the upper adapter case with 2 screws (accessory). FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 47 10.2.3 To check the functionality of the adapter 1 Turn on the power supply and check that the RUN lamp of the product blinks. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 48 2 Follow the directions on the screen to install the ONECTA app. INFORMATION Scan the QR code to download and install the ONECTA app on your mobile phone or tablet: FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 49 4 Press simultaneously: Model Buttons FTXP FTXF, ATXF 5 Press: Model Button FTXP FTXF, ATXF 6 Select: Model Symbol FTXP FTXF, ATXF 7 Press: Model Button FTXP FTXF, ATXF FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 50 In case you could NOT complete the setting in time, turn the power supply off and wait at least 1 minute before turning the power supply back on. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 51 12 Commissioning NOTICE General commissioning checklist. Next to the commissioning instructions in this chapter, a general commissioning checklist is also available on the Daikin Business Portal (authentication required). The general commissioning checklist is complementary to the instructions in this chapter and can be used as a guideline and reporting template during commissioning and hand-over to the user.
  • Page 52 3 Press twice. Result: will appear on the display. Test run operation is selected. Test run operation will stop automatically after about 30 minutes. 4 To stop operation, press FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 53 Some of the functions CANNOT be used in the test run operation mode. If a power failure occurs during operation, the system automatically restarts immediately after power is restored. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 54 Show the user what to do for the maintenance of the unit. ▪ Explain about energy saving tips to the user as described in the user reference guide. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 55 Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 56 A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of the latest technical data is available on the Daikin Business Portal (authentication required). 15.1 Wiring diagram The wiring diagram is delivered with the unit, located on the inner right side of the indoor unit front grille.
  • Page 57 Pulse-amplitude modulation PCB* Printed circuit board Power module Switching power supply PTC* PTC thermistor Insulated gate bipolar transistor (IGBT) Circuit breaker Q*DI, KLM Earth leak circuit breaker FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 58 (IGBT) power module Wireless remote controller Terminal Terminal strip (block) Electronic expansion valve coil Y*R, Y*S Reversing solenoid valve coil Ferrite core ZF, Z*F Noise filter FTXF-F, ATXF-F, FTXP-N Installer reference guide Daikin room air conditioner 4P518023-14U – 2024.09...
  • Page 59 Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
  • Page 60 4P518023-14U 2024.09...