10.4 pH2 Demand or Prime – Add acid manually or prime clear flexible PVC tubes
The 'pH2 DEMAND or PRIME' quantity can be manually adjusted from 0 - 5000 ml. The default
reading is always 100 ml. This function is useful for:
-
Priming tubes after an acid drum change.
-
Adding the required acid from your acid demand test.
IMPORTANT: Enter the exact amount from your test result in ml (e.g., 500 ml) and the
system automatically adds 4 times that amount, thereby allowing for the 1 : 3 ACID:
WATER mix ratio in the acid drum.
PROCEDURE
To enter a required amount of acid in mL, enter the 'pH2 Demand or
Prime' menu from the 'pH Control Mode' menu explained in 10.1, using the
[+], [-] & [OK] button
pH CONTROL MODE
LCD DISPLAY
pH1 Run Time
pH2 Demand or Prime
[+]UP[-]DN [OK]ENTER
PROCEDURE
The LCD will now show 'Acid Demand: 100 ml'.
Press [+] or [-] to adjust the quantity of acid required in millilitres (ml).
Pressing [OK] saves the required quantity, the peristaltic pump starts
turning and the ml reading starts counting down.
You can adjust the quantity in this menu if you wish or you can press [<]
and return to the chlorinator default display screen.
If the lines are primed, you can stop the peristaltic pump by entering a
reading of '0 ml'.
LCD DISPLAY
pH2 DEMAND OR PRIME
Acid Demand: 100 ml
[+] or [-] to change
[OK] SAVE [<] BACK