Commercial Microwave—Technical Information
208/230 VAC, 60 Hz Models
ASE70002
DQ22HSI2
KFC2SA2
RC17SD22
RC27S2
MC23MPTW2
• Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
• Refer to Service Manual RS2240003 for installation, operating, testing, troubleshooting, and disassembly
instruction.
All safety information must be followed as provided in Service Manual RS2240003.
To avoid the risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Models
RC17S2
RC17SD22
Power Source
Voltage AC
208/230 VAC
Amperage (Single
Unit)
Frequency
Single Phase, 3 wire
grounded
Receptacle
Plug
Power Output −
Microwave
Nominal microwave
1700 Watts
energy (IEC705)
Operating Frequency
2450 MHz
Power Consumption
Microwave only
2700 Watts
Dimensions
Cabinet (in cm)
Width
19 1/4"
Height
18 1/4"
Depth
26 1/4"
Oven Interior (in cm)
Width
13"
Height
8 1/2"
Depth
15"
Weight
Uncrated
Crated
** MC23MPTW2, MC23MPW2 uses 20A Twist−Loc NEMA L6-20P plug
March 2005
©2005 Maytag Services
P1331412M
P1331404M
P1331411M
P1331402M
P1331414M
P1331406M
!
!
DQ22HSI2
RC22S2
208/230 VAC
20 A
20 A
60 Hz
60 Hz
X
X
6-20R
6-20R
6-20P
6-20P
2200 Watts
2450 MHz
3200 Watts
49 cm
19 1/4"
49 cm
46 cm
18 1/4"
46 cm
67 cm
26 1/4"
67 cm
33 cm
13"
33 cm
22 cm
8 1/2"
22 cm
38 cm
15"
38 cm
94 lbs.
94 lbs.
101 lbs.
101 lbs.
ASE90002
KFC2W2
RC17S2
RC22S2
RC30S2
MC23MPW2
CAUTION
WARNING
ASE90002
RC27S2
RC30S2
KFC2W2
KFC2SA2
208/230 VAC
208/230 VAC
30 A
30 A
60 Hz
60 Hz
X
6-30R
6-30R
6-30P
6-30P
3000 Watts
2700 Watts
2450 MHz
2450 MHz
4400 Watts
4100 Watts
19 1/4"
49 cm
19 1/4"
18 1/4"
46 cm
18 1/4"
26 1/4"
67 cm
26 1/4"
13"
33 cm
13"
8 1/2"
22 cm
8 1/2"
15"
38 cm
15"
115 lbs.
115 lbs.
123 lbs.
123 lbs.
1
P1331413M
P1331410M
P1331401M
P1331403M
P1331415M
P1331405M
ASE70002
208/230 VAC
20 A
60 Hz
X
X
6-20R
6-20P
2500 Watts
2450 MHz
3700 Watts
49 cm
19 1/4"
49 cm
46 cm
18 1/4"
46 cm
67 cm
26 1/4"
67 cm
33 cm
13"
33 cm
22 cm
8 1/2"
22 cm
38 cm
15"
38 cm
115 lbs.
123 lbs.
MC23MPTW2
MC23MPW2
208/230 VAC
20 A
60 Hz
X
**
**
2000 Watts
2450 MHz
3200 Watts
19 1/4"
49 cm
18 1/4"
46 cm
26 1/4"
67 cm
13"
33 cm
8 1/2"
22 cm
15"
38 cm
115 lbs.
123 lbs.
16025966

Advertisement

loading
Need help?

Need help?

Do you have a question about the ASE70002 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maytag ASE70002

  • Page 1 94 lbs. 94 lbs. 115 lbs. 115 lbs. 115 lbs. 115 lbs. Crated 101 lbs. 101 lbs. 123 lbs. 123 lbs. 123 lbs. 123 lbs. ** MC23MPTW2, MC23MPW2 uses 20A Twist−Loc NEMA L6-20P plug March 2005 16025966 ©2005 Maytag Services...
  • Page 2 Note: This test is not conclusive. If oven does not heat and all other components test good replace the magnetron and retest. Blower motor Remove all wires from motor. Approximately 25 Ω Measure resistance across coil ....16025966 March 2005 ©2005 Maytag Services...
  • Page 3 Approximately 12K Ω Terminal to terminal ........Refer to Parts Manual Power cord Measure resistance of wires. Continuity should be indicated on for proper power cord each wire. part number. Verify polarity and grounding. March 2005 16025966 ©2005 Maytag Services...
  • Page 4 Volts Test points A and B 3.0 VAC Board Board If voltage is present and no display is indicated, replace display board. If no voltage is present, check wire harness connections and H.V. board. 16025966 March 2005 ©2005 Maytag Services...
  • Page 5 Test mode 5 off − no continuity K2 at Blower motor Disconnect Ohms J1 pin 1 (Brown wire) Test mode 5 on − < 1 Ω 208 VAC Antenna motor J2 connector & J2 pin 3 line voltage Cavity light March 2005 16025966 ©2005 Maytag Services...
  • Page 6 To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before servicing, unless testing requires power. H.V. Board − Relay Test Three Magnetron Models − ASE70002, ASE90002, KFC2W2, KFC2SA2, MC23MPTW2, MC23MPW2, RC27S2, and RC30S2 Relay...
  • Page 7 H.V. System # 3 Top Rear Magnetron Top Front Magnetron Bottom Magnetron Center Transformer Left Transformer Right Transformer Bottom Center Capacitor Top Left Capacitor Right Capacitor Diode Diode Diode Center Triac Left Triac Right Triac March 2005 16025966 ©2005 Maytag Services...
  • Page 8 Two Magnetron Models H.V. System # 1 H.V. System # 3 Top Rear Magnetron Bottom Magnetron Left Transformer Right Transformer Top Capacitor Bottom Capacitor Diode Diode Left Triac Right Triac 16025966 March 2005 ©2005 Maytag Services...
  • Page 9 7.5..... 1400 13 .... 2400 17 ....1700 25 ....2500 9.5..... 1700 13.5 ..2500 18 ....1800 27 ....2700 10....1800 15 .... 2700 19 ....1900 30 ....3000 10.5... 1900 16.5 ..3000 March 2005 16025966 ©2005 Maytag Services...
  • Page 10 Door Interlock Primary Switch Verify latch mechanism moves freely on door. • Verify J1 connector on display board is properly seated. • Test interlock switch assembly and perform door adjustment if necessary. • Replace interlock switch assembly. 16025966 March 2005 ©2005 Maytag Services...
  • Page 11 K7 if 208 VAC, and triac 3 Toggles Magnetron 3 drive voltage T1 - G) (Bottom) ON/OFF. Timer counts up to 62 seconds and unit shuts off. Wiring If voltage is present, check: H.V. components and wiring. March 2005 16025966 ©2005 Maytag Services...
  • Page 12 Temperature OFFSET is I T E M S T G Q T Y P O W E R NOT applicable with these models. Temperature OFFSET COOK PREHEAT READY STANDBY L M T LEVEL NOT APPLICABLE 16025966 March 2005 ©2005 Maytag Services...
  • Page 13 Wiring Diagram and Schematic W ARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before servicing, unless testing requires power. 12719301 DQ22HSI2 RC17S2 RC17SD22 RC22S2 March 2005 16025966 ©2005 Maytag Services...
  • Page 14 Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before servicing, unless testing requires power. 12719301 DANGER HIGH VOLTAGE DQ22HSI2 RC17S2 RC17SD22 RC22S2 16025966 March 2005 ©2005 Maytag Services...
  • Page 15 W ARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before servicing, unless testing requires power. 12719101 ASE70002 ASE90002 KFC2W2 KFC2S MC23MPTW2 MC23MPW2 RC27S2 RC30S2 March 2005 16025966 ©2005 Maytag Services...
  • Page 16 To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before servicing, unless testing requires power. 12719101 DANGER HIGH VOLTAGE ASE70002 ASE90002 KFC2W2 KFC2S MC23MPTW2 MC23MPW2 RC27S2 RC30S2 16025966 March 2005 ©2005 Maytag Services...