Download Print this page
Deye SUN-60K-G04P3-EU-AM4 User Manual

Deye SUN-60K-G04P3-EU-AM4 User Manual

Grid-connected pv inverter

Advertisement

Quick Links

Grid-connected PV Inverter
SUN-��K-G��P�-AU-AM�
SUN-��K-G��P�-AU-AM�
User Manual
R
SUN-��K-G��P�-AU-AM�
SUN-��K-G��P�-AU-AM�

Advertisement

loading
Need help?

Need help?

Do you have a question about the SUN-60K-G04P3-EU-AM4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Deye SUN-60K-G04P3-EU-AM4

  • Page 1 Grid-connected PV Inverter SUN-��K-G��P�-AU-AM� SUN-��K-G��P�-AU-AM� SUN-��K-G��P�-AU-AM� SUN-��K-G��P�-AU-AM� User Manual...
  • Page 2 �. Introduction ���������������������� - 1 - 1.1 Appearance Introduction �������������������� - 1 - 1.2 Labels description ������������������������ - 1 - 1.3 Parts list �������������������� - 2 - 1.4 Product handling requirements ���������������� - 3 - �. Safety warnings and instructions ���������������...
  • Page 3 �. Zero-export function via energy meter ����������� - 20 - 7.1 Multiple strings and parallel connection meters ��������� - 30 - 7.2 How to browse the load power of your PV grid-tieplant on monitoring platform? - 40 - �. General Operation �����������������...
  • Page 4 Documents must be stored carefully and be available at all times. Contents may be periodically updated or revised due to product development. The information in this manual is subject to The latest manual can be acquired via service@deye.com.cn change without notice. �. Introduction �.�...
  • Page 5 �.� Labels description Label Description Caution, risk of electric shock symbol indicates important safety instructions, which if not correctly followed, could result in electric shock. The DC input terminals of the inverter must not be grounded. CE mark of conformity Please read the instructions carefully before use.
  • Page 6 Three-Phase Smart Meter Solar Photovoltaic HJA4 Core Wire Female Connector Special *Sensor Clamp(optional) Meter(optional) Connector - Screw Crimp x1 Spanner x1 User manual Installation screws M5× 12 DRM connector User manual x1 Datalogger (optional) x1 �.� Product handling requirements Lift the inverter out of the packing box and transport it to designated installation location. transport CAUTION: Improper handling may cause personal injury!
  • Page 7 �. Safety warnings and instructions Improper use may result in potential electric shock hazards or burns. This manual contains important instructions that should be followed during installation and maintenance. Please read these instructions carefully before use and keep them for future reference. �.�...
  • Page 8 �.� Notes for using The single phase string power inverter is designed and tested under related safety regula- tions. It can ensure the personal safety of the user. But as a electric device, it may cause shock or injury by incorrect operation. Please operate the unit under below requirements: 1.
  • Page 9 �.� Status Indicator The inverter panel has 4 indicators, the left one is dc output indicators, green indicates normal DC input. Beside is the AC indicator, green indicating normal ac connection. Beside the AC indicator is the operating indicator, green indicating normal output. The right indicator is alarm.
  • Page 10 �. Product installation �.� Select installation location To select a location for the inverter, the following criteria should be considered: WARNING: Risk of fire Do not install the inverter in areas containing highly flammable materials or gases. ● Do not install the inverter in potentially explosive atmospheres. ●...
  • Page 11 Install on a wall or strong structure capable of bearing the weight. ● Install vertically with a maximum incline of +15°. If the mounted inverter is tilted to an ● angle greater than the maximum noted, heat dissipation can be inhibited, and may result in less than expected output power.
  • Page 12 ≥500mm ≥500mm Pic 4.3 Installation Gap �.� Mounting bracket of inverter Pic 4.4 Mounting bracket dimensions - 09 -...
  • Page 13 �.� Installations Tools Installation tools can refer to the following recommended ones. Also, use other auxiliary tools on site. table 4-1 Tool specification Anti-dust mask Protective goggles Earplugs Work gloves Work shoes Utlity Knife Slotted screwdriver Cross screwdriver Percussion drill Pliers Marker Level...
  • Page 14 �. Electrical Connection �.� PV Module Selection: When selecting proper PV modules, please be sure to consider below parameters: 1) Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter. 2) Open circuit Voltage (Voc) of PV modules should be higher than min. start voltage. 3) The PV modules used to connected to this inverter shall be Class A rating certified according to lEC 61730.
  • Page 15 Safety Hint: Please use approved DC cable for PV system. Cross section(mm ) Cable type Range Recommended value Industry generic PV cable 2.5-4.0 2.5(12AWG) (model: PV1-F) (12-10AWG) Table 5.1 DC Cable Specifications The steps to assemble the DC connectors are listed as follows: a) Strip off...
  • Page 16 DC input current should be 20A. if exceeds, it may damage the inverter and it is not covered by Deye warranty. Note: In a PV circuit for which the conductors are selected based on the short-circuit rating of the array, there is typically no risk of overloading conductors in the array wiring.
  • Page 17 AC wire installation method: 1) Remove the 4 screws on the inverter junction box and remove the junction box cover in Pic 5.7. After removing the junction box, you can see the terminals of the inverter. The default is 4 digits as shown in Pic 5.8.
  • Page 18 3) Screw the AC connection cover back to the shell and tighten all the screws to tighten the waterproof protection connector, as shown in Pic 5.11 Pic 5.11 Tighten the AC junction box �.�.� Recommended current protector specifications Rated voltage Rated output power(KW)...
  • Page 19 Pic 5.12 The installation of the shell ground wire Recommend Wire Size Model Torque value(max) copper cable (mm ) ��.�Nm �� �AWG SUN-��K-G��P�-AU-AM� SUN-��K-G��P�-AU-AM� ��.�Nm �AWG �� SUN-��K-G��P�-AU-AM� �� ��.�Nm �AWG SUN-��K-G��P�-AU-AM� �� �AWG ��.�Nm Table 5.3 Recommened cable specifications Warning: Inverter has built-in leakage current detection circuit, The type A RCD can be connected to the inverter for protection according to the local laws and regulations.
  • Page 20 Phone GPRS Router Web Server WIFI Pic 5.13 Internet monitoring solution �.�.� Installation of datalogger When installing the WiFi stick, tear off the sealing strip on the inverter. Insert the datalogger into the interface and fix it with a screw. The configuration of the datalogger needs to be performed after various electrical connections have been completed and the inverter DC power on.
  • Page 21 �. Start up and Shut off Ensure that the inverter meets the following conditions before starting the inverter, otherwise it may cause fire or damage to the inverter without quality assurance, at the same time the situation on our company does not undertake any responsibility. At the same time, to optimize the system configuration, it is recommended that the two inputs be connected to the same number of PV modules.
  • Page 22 �.� Anti-PID Function(option) Inverter The Anti-PID module repairs the PID effect of the PV module at night.The PID module always runs when connected to AC. If maintenance is required and turn off the AC switch can disable the Anti-PID function. Warning: The PID functionality is automatic.When the DC bus voltage is below 50VDC, the PID module will create 450VDC between the PV and ground.No control and equipment are required.
  • Page 23 Definition DRM1/5 DRM2/6 DRM3/7 1 2 3 4 5 6 DRM4/8 REF GEN/0 �. Zero-export function via energy meter There're four kinds of energy meters for this series inverter. First type is Eastron SDM630-Mod- bus V2 which is able to measure the Max. 200A current directly. More details please refer to Pic 7.1 &...
  • Page 24 1 2 3 4 5 6 7 8 Eastron (�,�,�,�) (�,�,�,�) B A G RS ��� RS 485 B RS 485 A Eastron SDM630-Modbus V2 Pic 7.1 Eastron meter Inverter Solar Panel array AC Breaker RS 485 Male connector Home load VCC_5V 485_B N L3 L2 L1...
  • Page 25 1 2 3 4 5 6 7 8 Eastron (�,�,�,�) (�,�,�,�) B A G RS ��� RS 485 B RS 485 A Eastron SDM630-Modbus V2 Pic 7.3 Eastron meter Inverter Solar Panel array AC Breaker RS 485 Male connector Home load VCC_5V 485_B N L3 L2 L1...
  • Page 26 9 1 0 11 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Eastron 1 2 3 4 15 16 17 18 19 20 Grid voltage Auxiliary Current inputs sampling power supply ��...
  • Page 27 9 1 0 11 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Eastron 1 2 3 4 15 16 17 18 19 20 Grid voltage Auxiliary Current inputs sampling power supply ��...
  • Page 28 (�,�,�,��) (�,�,�,��) Three-Phase Smart Meter RS ��� CHNT DTSU666 Pic 7.9 CHNT meter Solar Panel array Inverter AC Breaker RS 485 Male connector Home load L1 L2 L3 N VCC_5V 485_B RS 485 Female connector Three-Phase Smart Meter meter 485_A L1 L2 L3 N 485_A 485_B...
  • Page 29 (�,�,�,��) (�,�,�,��) Three-Phase Smart Meter RS ��� CHNT DTSU666 Pic 7.11 CHNT meter Inverter Solar Panel array AC Breaker RS 485 Male connector L1 L2 L3 N Home load VCC_5V 485_B RS 485 Female connector Three-Phase Smart Meter meter 485_A L1 L2 L3 N 485_A 485_B...
  • Page 30 6 9 10 1314 16171921 Three-Phase Smart Meter 230/400V, 3~100A/40mA 50/60Hz 24 25 Phase A current =5.000A 13 14 16 17 19 21 RS485 CHNT DTSU666 Phase B current =5.001A 3x230/400V 100A/40mA Pic 7.13 CHNT meter Phase C current =5.002A Inverter Solar Panel array AC Breaker...
  • Page 31 6 9 10 1314 16171921 Three-Phase Smart Meter 230/400V, 3~100A/40mA 50/60Hz 24 25 Phase A current =5.000A 13 14 16 17 19 21 RS485 CHNT DTSU666 Phase B current =5.001A 3x230/400V Pic 7.15 CHNT meter Phase C current =5.002A Inverter Solar Panel array AC Breaker RS 485...
  • Page 32 1. Press Enter button on the LCD panel in the main interface into the menu options, select [parameter setting] to enter setup submenu, and then select [run param], at this time please input the default password 1234 through pressing the button [up down, enter], enter the operation parameter setting interface, shown as picture 7.17.
  • Page 33 �.� Multiple strings and parallel connection meters This application is that when the string inverters work in parallel, there is only one power grid and one load, and only one meter can be connected to prevent reverse current, so only this many-to-one anti-reverse current connection can be connected.
  • Page 34 Name Description Range AVG: Average power of three phase is zero exported. AVG/MIN Exp_Mode MIN: Phase with minimum load power is zero exported, while the other two phase may be in purchase mode. CT ratio of power grid side meter when extern 1-1000 CT_Ratio CT is applied.
  • Page 35 1 2 3 4 5 6 7 8 Eastron (�,�,�,�) (5,6,7,8) B A G RS 485 RS 485 B RS 485 A Eastron SDM���-Modbus V� Pic �.�� Eastron meter Master(Mst) Grid L1 L2 L3 N RS��� 485_B 485_A VCC_5V 485_B RS 485 Female connector Slave2(Slv2)
  • Page 36 1 2 3 4 5 6 7 8 Eastron (�,�,�,�) (5,6,7,8) B A G RS 485 RS 485 B RS 485 A Eastron SDM���-Modbus V� Pic �.�� Eastron meter Master(Mst) Generator L1 L2 L3 N RS��� 485_B 485_A VCC_5V 485_B RS 485 Female connector Slave2(Slv2)
  • Page 37 9 1 0 11 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Eastron 1 2 3 4 15 16 17 18 19 20 Grid voltage Auxiliary Current inputs sampling power supply ��...
  • Page 38 9 1 0 11 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Eastron 1 2 3 4 15 16 17 18 19 20 Grid voltage Auxiliary Current inputs sampling power supply ��...
  • Page 39 (�,�,�,��) (�,�,�,��) Three-Phase Smart Meter RS ��� CHNT DTSU666 Pic �.�� CHNT meter Master(Mst) AC Breaker Solar Panel array Slave1(Slv1) AC Breaker Solar Panel array AC Breaker Slave2(Slv2) Solar Panel array AC Breaker load VCC_�V ���_B RS ��� Female connector ���_A Master(Mst) RS���...
  • Page 40 (�,�,�,��) (�,�,�,��) Three-Phase Smart Meter RS ��� CHNT DTSU666 Pic �.�� CHNT meter Master(Mst) AC Breaker Solar Panel array Slave1(Slv1) AC Breaker Solar Panel array AC Breaker Slave2(Slv2) Solar Panel array AC Breaker load VCC_�V ���_B RS ��� Female connector ���_A Master(Mst) RS���...
  • Page 41 6 9 10 1314 16171921 Three-Phase Smart Meter 230/400V, 3~100A/40mA 50/60Hz 24 25 Phase A current =5.000A 13 14 16 17 19 21 RS485 CHNT DTSU666 Phase B current =5.001A 3x230/400V Pic �.�� CHNT meter Phase C current =5.002A Master(Mst) AC Breaker Solar Panel array Slave1(Slv1)
  • Page 42 6 9 10 1314 16171921 Three-Phase Smart Meter 230/400V, 3~100A/40mA 50/60Hz 24 25 Phase A current =5.000A 13 14 16 17 19 21 RS485 CHNT DTSU666 Phase B current =5.001A 3x230/400V Pic �.�� CHNT meter Phase C current =5.002A Master(Mst) AC Breaker Solar Panel array Slave1(Slv1)
  • Page 43 �.� How to browse the load power of your PV grid-tie plant on monitoring platform? If you want to browse load power of the system and how much energy (KWH) does it export to grid(inverter output power is used to power the load firstly and then the surplus energy will feed into grid).
  • Page 44 Secondly, go to plant page, if it shows the PV power, load power and grid power, which means the configuration is correct. String inverter Solar Station Back to Plants list ID����� Compare Edit More Partially Offline No Alerts Last update ����/��/�� ��:��:�� UTC+��:�� String inverter Solar Sta...
  • Page 45 �. General Operation During normal operation, the LCD shows the current status of the inverter, including the current power, total generation, a bar chart of power operation and inverter ID, etc. Press the Up key and the Down key to see the current DC voltage, DC current, AC voltage, AC current, inverter radiator temperature, software version number and Wifi...
  • Page 46 ActiveP Q-Mode ReactP Exp_Mode Fun- ISO CT_Ratio 0 Fun RCD FeedIn SelfCheck Shunt ShuntQTY Island Generator G.CT Meter G.MFR G.FeedIn Limiter Setup G.Cap Feed-in Running param MPPT Num OF-Derate UF-Uprate WGRa WGraStr HardLim VRef SoftLim PowerLim VoltageRT Sunspec OK Cancel - 43 -...
  • Page 47 *Note: These parameters will be avaiable after the meter is INMETRO connected successfully. Otherwise, it won't show. EN50549 Attention: For running param detail on the LCD display, please EN50438 refer to the official Deye website https://www.deyeinverter.com IEC61727 CUSTOM VDE_4105 UTE_C15 RD1699...
  • Page 48 �.� The initial interface From the initial interface, you can check power, daily generation, gross generation, invertert ID , model and time. �.�Kw SN-�� ����-��-�� ��:��:�� P - �� Kw Power: ��.��Kw Day : ���kWh Total : �� MWh State : Standby �...
  • Page 49 Grid Ua : ���.�V Ia : �.�A Grid Freq : ��.��Hz PF : �.��� Pic 8.3 AC running state information You can check the three phase voltage, current, and grid frequency. Total DC Power: �.���W Lcd���� Inv���� Pic 8.4 Inverter firmware version You can check the inverter LCD software Ver0196 and Control Software Version Ver1400.
  • Page 50 �.�.� Main Menu There are four submenu in the Main Menu. MENU Statistics 《 Fault Record ON/OFF Setup Pic 8.6 Main Menu �.� Statistics information There are five submenu in the statistics. MENU》 Statistics E-Day E-History E-Month Test Data 《 E-Year Pic 8.7 Statistics Into each submenu through cursor.
  • Page 51 MENU》 Statistics》 E-Day <����-��-��> ��MWh � � �� �� �� Pic 8.8 E-Day MENU》 Statistics》 E-Month ����-�� �-�� �� �� <> ��MWh �� �� �� �� �� �� �� �� �� �� Pic 8.9 E-Month MENU》 Statistics》 E-Year <����> ���KWh ��...
  • Page 52 MENU》 Statistics》 E-History <����-����> �KWh �� �� �� �� �� �� �� �� �� �� Pic 8.11 E-History This information is for technician’s reference. PV� ����� �k� ����� ���� PV� ����� �k� ����� ��� : ���� ����� �k� ����� ��� ����...
  • Page 53 �.� ON/OFF setting MENU》 ON/OFF Turn ON Turn OFF 《 Pic 8.14 ON/OFF setting Into each submenu through cursor. MENU》 ON/OFF》 Turn ON 《 Turn ON Cancel Pic 8.15 ON set MENU》 ON/OFF》 Turn OFF 《 Turn OFF Cancel Pic 8.16 OFF set - 50 -...
  • Page 54 �.� Parameter setting Setting includes system param, run param, protect param, comm.. param. All of these information for maintenance reference. MENU》 Setup System Param 《 Param Protect Param Comm. Param Pic 8.17 Setting �.�.� System Param System Param MENU》 Setup 》 Time Set Language Set Display Set...
  • Page 55 �.�.�.� Time Set Time Set ����-��-�� ��:��:�� Cancel Pic 8.18 System Param �.�.�.� Language Set Lauguage Set 简体中文 English 《 Polski Pic 8.19 Lauguage set �.�.�.� Display Set Display Set Brightness Keep 《 Delay time ��S Cancel Pic 8.20 Display set - 52 -...
  • Page 56 �.�.�.� Factory data reset Factory data reset Confirm to reset 《 Cancel Pic 8.21 Factory data reset set �.�.�.� Setting Restore Setting Restore Confirm to restore 《 Cancel Pic 8.22 Factory data reset set Warning: Password required-- only for access-authorized engineer. Un-authorized access may avoid the warranty.
  • Page 57 �.�.� Protect Param MENU》 Setup》 Protect Param GridStandard 《 Advanced Cancel Pic 8.23 Protect Param Warning: Engineer only. Standard Brazil EN�����-�-PL EN�����-� IEC����� Custom 《 VDE���� Cancel Standard VDE���� Spain CEI � �� 《 G�� G�� NBT�����-B Cancel - 54 -...
  • Page 58 Standard Australia-A Australia-B Australia-C 《 New Zealand Cancel Standard Norway Switerland R�� 《 CEI-��� Cancel Pic 8.24 “Standard” - VoltageTriping Tov_� ����ms OV_� ���.�V Tov_� ����ms OV_� ���.�V OV_� ���.�V Tov_� ����ms UV_� ���.�V Tuv_� ����ms Tuv_� ����ms UV_� ���.�V Tuv_�...
  • Page 59 - FrequencyTriping Tof_� ����ms OF_� ��.��Hz Tof_� ����ms OF_� ��.��Hz OF_� ��.��Hz Tof_� ����ms Tuf_� ����ms UF_� ��.��Hz Tuf_� ����ms UF_� ��.��Hz Tuf_� ����ms UF_� ��.��Hz Cancel - Miscellaneous �.�% Vrc_H �.�V Vrc_L �.�V Frc_H �.�Hz Frc_L �.�Hz VGrid ���/���V OV��Min Cancel Pic 8.25 “Advanced”...
  • Page 60 �. Repair and Maintenance String type inverter doesn’t need regular maintenance. However, debris or dust will affect heat sink’s thermal performance. It is better to clean it with a soft brush. If the surface is too dirty and affect the reading of LCD and LED lamp, you can use wet cloth to clean it up. High Temperature Hazard: When the device is running, the local temperature is too high and the touch can cause burns.
  • Page 61 Check the solar panel output connection. Failure in reading memory (EEPROM). Restart the inverter if the Read the memory error fault still exists, contact your installer or Deye service. Failure in writing memory (EEPROM). Restart the inverter if the Write the memory error fault still exists, contact your installer or Deye service.
  • Page 62 The DC busbar is unbalanced 2. Restart the inverter, if the fault still exists, contact your installer or Deye service. DC end insulation error Hardly appear the code. Never ever happened so far. Inverter 1 DC high fault Hardly appear the code.
  • Page 63 1. Check AC current sensor and its circuit. AC over current(one cycle) 2. Restart the inverter, if the fault still exists, contact your installer or Deye service. DC over current Hardly appear the code. Never ever happened so far. Check the AC voltage protection setting. And Check if the AC AC Line W,U over voltage cable is too thin.Check the voltage difference between LCD and...
  • Page 64 Error code Description Ongrid - Three Phase AC grid V over current Hardly appear the code. Never ever happened so far. AC grid W over current Hardly appear the code. Never ever happened so far. Reactor A phase over current Hardly appear the code.
  • Page 65 ��.Specification Model SUN-��K-G��P� SUN-��K-G��P� SUN-��K-G��P� SUN-��K-G��P� -AU-AM� -AU-AM� -AU-AM� -AU-AM� PV String Input Data Max. PV Input Power(kW) 112.5 Max. PV Input Voltage(V) 1100 Start-up Voltage(V) PV Input Voltage Range(V) 250-1100 MPPT Voltage Range(V) 200-1000 Rated PV Input Voltage(V) Full Load MPPT Voltage Range(V) 490-850 570-850 610-850...
  • Page 66 Interface Communication Interface RS485/RS232 Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional) Display LCD+LED General Data Operating Temperature Range (°C) -25 to +60℃,>45℃ derating Permissible Ambient Humidity 0-100% Permissible Altitude (m) 4000m Noise (dB) ≤ 55dB Ingress Protection(IP) Rating IP 65 Inverter Topology Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC) Cabinet Size(W*H*D)[mm] 698×613×236.5 (Excluding connectors and brackets)
  • Page 67 Add. : No.�� South YongJiang Road, Daqi, Beilun, NingBo, China. Tel. : +�� (�) ��� ���� ���� Fax. : +�� (�) ��� ���� ���� E-mail. : service@deye.com.cn Web. : www.deyeinverter.com...