BestScope BM0506 Series Instructions Manual

Biological microscope

Advertisement

Quick Links

BM0506
Series
Biological
Microscope
INSTRUCTIONS
This instruction manual is for the operation guide, trou bleshooting and
maintenance to the
series biological microscope. Please study this
BM0506
manual thoroughly before operating, and keep it with the instrument. The
manufacturer reserves the rights to the modifications by technology
development. On the basis of operation ensured, technical specifications
may be subject to changes without notice.
0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BM0506 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BestScope BM0506 Series

  • Page 1 BM0506 Series Biological Microscope INSTRUCTIONS This instruction manual is for the operation guide, trou bleshooting and maintenance to the series biological microscope. Please study this BM0506 manual thoroughly before operating, and keep it with the instrument. The manufacturer reserves the rights to the modifications by technology development.
  • Page 2: Table Of Contents

    Contents BM0506 Series Before Use ………………………………………………………………………..……...1 1. Components …...…….……………………………………………………………………...4 2. Assembling …………………………………..…………………………….4 2-1 Assembling Scheme 2-2 Assembling Steps…………………………..………………..….…………………5 …………………………………………………………………………….…….7 3. Operations 3-1 Set Illumination………….………….………………………………………..7 3-2 Place the Specimen Slide ..……….…………….…………………………...7 3-3 Adjust the Focus …………………………………...…….…………..…..7 3-4 Adjust the Focusing Tension…..……………………………………….….7 …………………………………………………………………8...
  • Page 3: Before Use

    Before Use BM0506 Series 1. Operation Notice 1. As the microscope is a high precision instrument, always operate it with care, and avoid physical vibrations. 2. Do not expose the microscope in the sun directly, either not in the high temperature, damp, dust or acute shake.
  • Page 4: Maintenance

    BM0506 Series 2. Maintenance 1. Wipe the lens gently with a soft tissue. Carefully wipe off the oil marks and fingerprints on the lens surfaces with a tissue moistened with a small amount of 3:7 mixture of alcohol and ether or dimethylbenzene.
  • Page 5: Components

    1. Components BM0506 Series Eyepiece Monocular Head Lock Screw Nosepiece Body Group Objective Stage Coarse Focusing Knob Condenser Fine Focusing Knob Light Adjustment Knob Indicator Light...
  • Page 6 BM0506 Series Body Binocular Head Eyepiece Group Objective Tension Adjustment Ring Stage Fine Focusing Knob Coarse Focusing Knob Illuminato...
  • Page 7 BM0506 Series Trinocular Head Eyepiece Lock Screw Nosepiece Body Group Objective Stage Coarse Focusing Condenser Knob Vertical Fine Focusing Adjustment Knob Knob Horizontal Light Adjustment Knob Indicator Adjustment Light Knob...
  • Page 8: Assembling

    2. Assembling BM0506 Series 2-1 Assembling Scheme Following is the Assembling Scheme, and the numbers denote the assembling order. ★ Before assembling, make sure there is no dust, dirt or other materials which will disturb it. Assemble carefully and do not scrap any part or touch the glass surface.
  • Page 9: Assembling Steps

    BM0506 Series 2-2 Assembling Steps 2-2-1 Assemble the Objective 1. Rotate the coarse focusing knob① to lower the stage to a suitable position (see Fig.3). 2.Then install the objectives into the nosepiece② from the lowest magnification to the highest in clockwisedirection.
  • Page 10 BM0506 Series ★ Use the special wire supplied by our company. If it’s lost or damaged, choose one in the same specifications. ★ Wide voltage range is supported as 100~240V. ★ Connect the power cord appropriately to make sure the instrument is connected to ground.
  • Page 11: Operations

    3. Operations BM0506 Series Set Illumination 1. Put through the power and adjust the light adjustment knob ① until the illumination is comfortable for observation.Rotate the light adjustment knob in clockwise to raise the voltage and brightness. Rotate the light adjustment knob in counterclockwise to lower the voltage and brightness (see Fig.7).
  • Page 12: Aperture Diaphragm

    BM0506 Series Aperture Diaphragm 1. The aperture diaphragm decides the numerical aperture of the illumination system. Only when the N.A. of illumination system is matching with the N.A. of the objective, it can obtain better resolution and contrast, and also increase the depth of field.
  • Page 13: Use Binocular Head /Trinocular Head(Optional

    BM0506 Series Use binocular head /trinocular head (Optional) 3-7-1 Adjust the Interpupillary Distance When observe with two eyes, hold the base of the prism and rotate them around the axis until there is only one field of view. “。”① on the eyepiece base points to the scale ②...
  • Page 14: Store The Power Cord

    BM0506 Series 3. Rotate the X and Y-axis knob③ of the stage, and move the specimen to the center (aligned with the center of objective). 3-8-2 Aperture Diaphragm 1. The aperture diaphragm decides the numerical aperture of the illumination system. Only when the N.A.
  • Page 15: Troubleshooting

    4. Troubleshooting BM0506 Series As the performance of microscope can’t play fully due to unfamiliar operations, the table below can provide some solutions. Problem Cause Solution 1. Optical Part Field diaphragm is not large Enlarge the field diaphragm. (1) The LED light is bright, enough.
  • Page 16 BM0506 Series Problem Cause Solution Adjust the interpupillary (6) The eyes feel tired Interpupillary distance is wrong. distance. easily. The right field of view doesn’t superpose Eyepieces for the left eye and Use the same eyepiece. with the left. right eye are different.

Table of Contents