Summary of Contents for Zip Water HydroTap G5 C HOME
Page 1
Contact us if you need support and advice. Zip Water Australia 67 - 77 Allingham Street, Condell Park NSW 2200 Postal: Locked Bag 80, Bankstown 1885 Australia, Tel (+612) 9796 3100, Free call 1800 947 827 (1800 ZIP TAP) Zip Water UK Trafalgar House, Rash’s Green, Dereham,...
Page 2
Safety information This document is a Quick Start Installation Guide. Download & read the full Command Centre installation instructions for more installation information. Explanation of symbols Read the Compressed Danger of instructions Gas WARNING electric shock Highly WARNING Lithium flammable Coin cell •...
Page 3
Safety information • This appliance may deliver water at high temperature. Refer to the Plumbing Code of Australia (PCA), local requirements and installation instructions to determine if additional delivery temperature control is required. • The button/coin battery is hazardous and is to be kept away from children. It can cause severe or fatal injuries in 2 hours or less if it is swallowed or placed inside any part of the body.
Page 4
Installation -Technical data, part supplied Review the technical data & parts supplied in the kit. Power rating, kW Dimensions Water supply Weight Model 220-240V, 50Hz W x D x H (mm) Connection (kg) C100 0.34 280 x 499 x 333 G 1/2 24.2 0.16...
Page 5
Ventilation installation instructions Make sure there’s enough ventilation in the cupboard, air needs to circulate as follows: Cold air is drawn in through the gaps provided by the door buffers (supplied), they must be fitted. Command Centre clearances must be observed. Warm air is expelled through the integrated vent in the base of the Command Centre, via the vent cut-out in the cupboard floor.
Page 6
Ventilation installation instructions C Home ventilation options Option 1: Ventilation arrangement using small cupboard with min. 40mm overhang Directing warm air straight into the room. Must be installed C l e a r a Inlet Must be installed Option 2: Ventilation arrangement using small cupboard with less than 40mm, or no overhang.
Page 7
Ventilation installation instructions C40, C100 ventilation options Option 3: Ventilation arrangement using large cupboard with min. 40mm overhang Directing warm air straight into the room. Must be installed C l e a r a Inlet Must be installed Extra Inlet vent option Option 4: Ventilation arrangement using small cupboard with min.
Page 8
Ventilation installation instructions Option 5: Ventilation arrangement if using a large cupboard with less than 40mm, or no overhang. Directing warm air into the kick space & out through a vent grille. Must be C l e installed a r a Inlet Both must be...
Page 9
General installation arrangement instructions Make sure the braided hose and adaptor arrangement for the mains water supply are installed as follows: 90º bend Mains cold water supply Inline Inline filter filter adaptor Command Centre Quick Reference Installation Guide 810009 v1.00 08.24 G5 C Quick Reference Installation Guide...
Page 10
C Home Installation Scan the QR code & read Install the HydroTap in order the instructions Install the vent mounting plate on the cupboard floor, scan the QR Code & read the instructions. Ventilation Install rail Installation UK only Instructions For UK, fit the install rail (scan the QR Code for instructions).
Page 11
C Home Commissioning Commission the HydroTap in order Commissioning process, follow screen prompts, scan HydroTap Clean QR for more information. HydroTap Clean If cupboard temperatures exceed 35 C additional ventilation will be required. Turn on water supply & To use the HydroTap, scan check for leaks.
Page 12
C100, C40 Installation Scan the QR Code & read Install the HydroTap in order the instructions Install the vent mounting plate on the cupboard floor, scan the QR Code & read the instructions. Ventilation Install rail Installation UK only For UK, fit the install Instructions rail (scan the QR Code for Fit the tap connections:...
Page 13
C100, C40 Commissioning Commission the HydroTap in order Commissioning process, follow screen prompts, scan HydroTap Clean QR for more information. If cupboard temperatures exceed 35 C additional ventilation HydroTap Clean will be required. To use the HydroTap, scan the User Guide QR Code & read the instructions.
Page 16
Refer to User Guide for operation and maintenance. As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods.
Need help?
Do you have a question about the HydroTap G5 C HOME and is the answer not in the manual?
Questions and answers