General Information ........................15 Moving the Chair ..........................15 Using the Chair on Level Ground and on Stairs ................. 16 Gliding the Chair Downstairs ......................16 Care of the MAX Chair (Non-Foldable) ....................17 6.1. Disinfection ............................17 6.2. Cleaning ............................17 Using additional help ........................
Improper charging can cause injury or damage. Use only recommended that training on the proper use of the Ferno-approved battery with the chair, and charge only with the Ferno-approved battery charger. this chair be provided before using this chair in an actual situation.
65-0409-001 MAX POWER (REMOVABLE TRACK) w/PWRTX 60-0251-008 MAX FASTENER 65-1500-031 IV POLE Ferno products meet the requirements of Medical Device Directive MDR 2017/745 as established by the European Union. The MAX Chair meets the following standards: • EN 1865-1:2010+A1:2015 •...
1.3. Back handles Back handles are used to lift the Max chair to overcome larges obstacles. Ensure the handles are in 90° position before attempting to lift or carry the chair. After using, return the handles to their original position.
Ferno Slovakia MAX Chair (Non-Foldable) 1.4. Wheels The Chair is fitted with two large wheels with brakes at the rear and two swiveling castors below the foot rest. The front swivel castors provide excellent maneuverability. ALWAYS inform the patient of your intentions.
Ferno Slovakia MAX Chair (Non-Foldable) 1.6. Attaching and detaching the MAX Power (track) When using the Max chair with the MAX Power: The chair features an attachable track to aid operators when ascending and descending stairs. To attach the track: First, position the tracks with the lock turned up to receive the axle of the chair.
Ferno Slovakia MAX Chair (Non-Foldable) 1.7. Fold & Unfold MAX Power (track) The track aids in descending stairs. Do not unfold the track if the chair is not needed to descend stairs. To fold the track into the back of the chair, push the lever downwards as shown, until t h e track...
The MAX Fastener is for use with Ferno® products only. No guarantee is given for usage with other carriers than those of Ferno. MAX Fastener is attached to the floor of the ambulance. The floor or tray to which the mounting components are attached must have sufficient strength to hold the mounted fastening system and MAX chair with patient.
2. Intendend use For the purpose of this manual, the MAX Chair will be referred to as the Chair and the person being transported on the Chair will be referred to as the patient. MAX Chair / non-foldable chair is a handling device designed for transporting patients to the ambulance.
Establish regular inspection procedures maintenance instructions in this manual. and responsibilities to ensure proper When using the Max chair with Max Power the back maintenance as described. handles must be folded down and telescopic In cases of cervical, spinal or some carrying handlers used.
-Refer to Quick Set-up Guide Guidelines for using the track system: • Using the Chair on stairs requires a minimum of two trained operators. FERNO Manufacturing recommends using a third person as a “spotter”. • Verify that the track is fully opened and locked into place before using it.
Chair should be conducted, the back panel and their head securely positioned preferably by FERNO Field care. on assy back panel. ● Operators must take extra precautions •...
5.3 Using the Chair on Level Ground and on Stairs 1. Head-end operator – fully extend the handle • The Max Chair is fitted with telescopic of Max Power and ensure it is locked. carrying handles to aid in carrying the chair when 2.
The upper handle position can be changed to provide a better hand grip. Always inform the patient about what is happening. 6. Care of the MAX Chair (Non-Foldable) 6.1. Disinfection Disinfect all surfaces of the Chair including the back and seat panel and patient restraints. Follow disinfectant manufacturers’...
MAX Chair (Non-Foldable) 7. Using additional help Operating the chair requires a minimum of two trained operators. Ferno recommends positioning a trained operator at each end of the chair, that operators and helpers face each other when transporting a patient up or down stairs, and that a third trained person “spot” for the lead operator. Follow all applicable local protocols for carrying chairs.
MAX Chair (Non-Foldable) 8. Maintenance The MAX Chair (Non-Foldable) requires regular maintenance. Set up and follow your own maintenance schedule but use the following as a minimum. More frequent maintenance will be required in situations of heavy use. If any damage is discovered, take the Chair out of service until repair or replacement can be made.