Page 3
6.1. Operator Skills ..........................31 6.2. Operator Training ..........................31 6.3. Warning ............................32 7. FAST Chair Operation ..........................33 7.1. Folding and Unfolding the Chair ..................... 33 7.2. Height Positional Upper Handle ..................... 33 7.3. Extending Carrying Handles ......................33 7.4.
Page 4
8.2. Moving the Chair ..........................36 8.3. Using the Chair on Level Ground ....................37 8.4. Gliding the Chair Downstairs ......................37 9. Care of the FAST Chair ..........................39 9.1. Disinfection ............................39 9.2. Cleaning ............................39 10. Using additional help ........................... 40 11.
Additional free copies are available upon Improper charging can cause injury or damage. Use request from FERNO Manufacturing. only the Ferno-approved battery with the chair, and charge only with the Ferno-approved battery charger. Using the chair with the track system unlocked can 500 lb cause injury.
Page 6
65-4128-001 ARMREST KIT 65-4137-001 FRONT WHEELS LOCKING KIT Ferno products meet the requirements of Medical Device Directive MDR 2017/745 as established by the European Union. The chair meets the following standards: • IEC 60601-1-2 (electrical and electromagnetic medical equipment standards) •...
Ferno Slovakia FAST Chair Removable Stair Powertraxx Using Patient Restraints Use the lap and foot restraints to secure Patient into the Chair. Assess Patient condition to determine optimum strapping procedure. • Chest/Hips Restraint: The chest restraint can also be used to secure the chair closed for stowage.
Ferno Slovakia FAST Chair Removable Stair Powertraxx • Releasing Restraints: To release foot, chest and hips restraints, squeeze the two sides of the tang on the buckle inwards at the same time to pull the buckle apart. 4-Point Restraints (accessory) 1.
1. Quick set-up guide 1.1 Unfold chair For the purpose of this guide, the FAST Chair will be referred to as the Chair and the person being transported on the Chair will be referred to as the patient. The Chair will normally be left in the folded condition and the first task will be to unfold and make the Chair safe for transporting a person.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 1.2. Adjust handle The chair is fitted with an adjustable height handle. To adjust the handle, the operator must pull up on the red cable under the handle. This disengages the handle to slide up or down. When the desired position is reached the operator must release the cable.
Ferno Slovakia FAST Chair Removable Stair Powertraxx Once the patient has been seated comfortably in the chair pull down the foot rest and place their feet on to it. Fasten all restraining straps to secure the patient. 1.3. Unfold & Fold track The track aids descent on stairs, do not unfold the track if the chair is not needed to descend stairs.
Ferno Slovakia FAST Chair Removable Stair Powertraxx To unfold the track from the rear of chair pull the bar fitted to the track until the track locks in to position. 1.4. Telescopic carry handles The chair is fitted with telescopic carrying handles to aid carrying the chair down stairs. To change position of the handles press button and pull/push handles to extend or shorten.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 1.5 Attaching the Track (Chair Occupied) The chair features an attachable track to aid operators when descending stairs. 1. With the Chair in the unfolded position, raise the red release handle at the bottom of the track and locate the lower track lock onto the axle.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 1.6 Attaching the Track (Chair NOT 1.7 Deploying the Track for Use Occupied) Once the Track are attached to the chair, they may be unfolded for use. When the Chair is not occupied, an alternative Whilst holding the Chair secure from the rear, method for attaching the Track is recommended.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 1.8 Stowing the Track 1.9 Removing the Track When not in use always ensure the Track is folded Prior to folding the chair for storage or using chair away securely to limit the chance of damage or as a carry chair, the Track must be removed.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 1.10. Fold chair Pull the red cable under the seat outward Fold the seat up Continue folding the seat into its folded position Folded position...
Ferno Slovakia FAST Chair Removable Stair Powertraxx 1.11. Foot rest Before folding the chair for storage ensure castors are locked facing forward, the foot rest is up and all handles are not extended. The foot support is part of this chair. For unfolding is necessary to pull the chair frame down and...
Ferno Slovakia FAST Chair Removable Stair Powertraxx 2. Power System WARNING 2.1 PowerTraxx Components DO NOT OPEN MOTOR. No user-serviceable parts inside. Contact Ferno The PowerTraxx consists of the following components: for service ● CONTROL PANEL: The control panel is attached to the lift bar.
Improper charging can cause injury or damage. Note: The battery and charger instructions from Milwaukee supersede those in this manual. For Use only the Ferno-approved battery with the additional information, see the manuals provided chair, and charge only with the Ferno-approved with these components.
Ferno Slovakia FAST Chair Removable Stair Powertraxx ● Typical charging time is about one hour. Actual charging time varies based on frequency of recharge, depth of discharge, and battery age. If a battery becomes deeply discharged, extend the charging time.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 2.2.4 Main Battery shutoff If the internal temperature of the battery becomes too high, the main battery will shut off to protect itself, and all powered chair motion stops. To verify the battery has overheated, press the test button on the battery.
Ferno Slovakia FAST Chair Removable Stair Powertraxx An adapter plug (not supplied) may be needed to adapt the charger plug for the outlet. Typical charging time is about one hour. If the batteries are deeply discharged, extend the charging time. Actual charging time may vary based on frequency of recharge, depth of discharge, and age of batteries.
Ferno Slovakia FAST Chair Removable Stair Powertraxx To use the chair: 1. Press (ON). 2. Tap a paddle up or down to awaken the wireless controller. 3. Allow a few seconds for the wireless connection to be established. When the control panel and motor link, the motor will emit three audible beeps.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 3. Control Panel 3.1 Control Panel Overview The control-panel components are: ● Brake Button - The symbol on this button is a “Stop Sign” with a slash through it. ● Indicator Light - The light is illuminated red, green, or is not illuminated to provide feedback to the user.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 3.2 Brake Button The brake prevents the belts from moving unless a paddle is pressed. By default, the brake is engaged when the system has power. To disengage or re-engage the brake, press the brake button on the control panel.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 3.3 Mode Button The mode button is the Ferno logo Press and hold for four seconds to show the chair status on the display. The display will show the current voltage and amperage used by the power system, plus the revolutions per minute (RPM) of the motor.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 3.5.2 AA batteries Two AA-size batteries power the control panel. If the AA battery warning icon ( ) appears in the upper right corner of the display, replace the AA batteries. Also, if there are no lights on the control panel and the paddles stop functioning, the AA batteries may need to be replaced.
If a fault occurs, the chair will stop functioning and the display will turn off. In all cases, contact EMSAR or your Ferno distributor for assistance. Control-Panel Fault (E1) – If there is a fault or damage to the control panel (such as a loose or cut wire), a warning triangle symbol and error code “E1”...
Ferno Slovakia FAST Chair Removable Stair Powertraxx 4. Additional PowerTraxx Information 4.1 Interconnect Cord The interconnect cord physically connects the control panel with the motor. It serves two purposes: ● (Optional) The interconnect cord can be connected permanently to bypass the wireless system. If you decide to use the interconnect cord permanently, arrange the cord so it will not be pinched by opening, closing, or using the chair.
7. If you completed all steps properly, the display will show “Calibration OK!” Begin using the chair normally. 4.2.3 If the calibration fails Repeat Steps 1-7. Do not press the paddles until directed to, and press in the proper direction. If the paddles cannot be recalibrated, contact Ferno Technical Support for assistance.
5. Intended use For the purpose of this manual, the FAST Chair will be referred to as the Chair and the person being transported on the Chair will be referred to as the patient. The Chair is a handling device designed to transport a patient, in a seated position, on stairs and level ground.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 6.3. Warning Warning notices indicate a potentially hazardous situation which if not avoided, could result in injury or death. WARNING WARNING ✓ Never exceed the maximum load Bleach, phenols and iodine can cause damage. Do not capacity of 227 Kg.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 7. FAST Chair Operation 7.2. Height Positional Upper Handle - Refer to Quick Set-up Guide The upper handle can be locked into four 7.1. Folding and Unfolding the Chair different positions to assist operations on stairs and also to allow for height variations The Chair folds for shipping and storage.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 7.4. Patient Restraint Use the lap and foot restraints to secure patient Guidelines for using the track system: into the Chair. Assess patient condition to determine optimum strapping procedure. • Using the Chair on stairs requires a minimum of two trained operators.
• Check that the track system opens and closes correctly, examine the tracks for damage. • Check the upholstery for cracks, splits or any loose fabric or stitching, etc. • Check that the upholstery is correctly secured to the frame. If in any doubt then contact a FERNO Fieldcare Service Engineer.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 8. Operating Procedure 8.1. General Information WARNING Regular cleaning helps reduce the risk IMPORTANT: of transmitting disease and enables the Always inform the patient before a manoeuvre. equipment to function at its optimum Chair operation requires a minimum of: 4.
Ferno Slovakia FAST Chair Removable Stair Powertraxx 8.3. Using the Chair on Level Ground • Before rolling the Chair on level ground, the head end operator adjusts the upper handle to the desired position for comfortable use. (Rear locking lift...
Page 38
Ferno Slovakia FAST Chair Removable Stair Powertraxx 1. Head-end operator – fully extend the upper handle and ensure it is locked. (see page 9). 2. Head-end operator – lower the track and ensure it is locked (see page 11) 3. Foot-end operator – take up position on the stairs facing the chair gripping the lower foot-end handle.
(See Section Upper Handle). The upper handle position can be changed to provide a better hand grip. Always inform the patient about what is happening. 9. Care of the FAST Chair 9.1. Disinfection Disinfect all surfaces of the Chair including the head pad and patient restraints. Follow disinfectant manufacturers’...
FAST Chair Removable Stair Powertraxx 10. Using additional help Operating the chair requires a minimum of two trained operators. Ferno recommends positioning a trained operator at each end of the chair, that operators and helpers face each other when transporting a patient up or down stairs, and that a third trained person “spot”...
FAST Chair Removable Stair Powertraxx 11. Maintenance The FAST Chair requires regular maintenance. Set up and follow your own maintenance schedule but use the following as a minimum. More frequent maintenance will be required in situations of heavy use. If any damage is discovered, take the Chair out of service until repair or replacement can be made.
Page 42
Ferno Slovakia FAST Chair Removable Stair Powertraxx TRAINING RECORD Date Name Training Method...
Page 43
Ferno Slovakia FAST Chair Removable Stair Powertraxx MAINTENANCE RECORD Date Maintenance Performed...
Need help?
Do you have a question about the FAST Chair and is the answer not in the manual?