Page 1
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER ENGLISH VERSION WARNING! Read this Operator’s Manual carefully before using this machine. Failure understand and follow the contents of this manual may result in electrical shock, fire and/or serious personal injury. READ CAREFULLY...
Page 2
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER...
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Table of Contents Safety Symbols General Safety Rules Work Area Safety Personal Safety Pressure Cleaner Use & Care Service High Pressure Cleaning Safety Description, Specifications And Standard Equipment Description Specifications Standard Equipment Machine Assembly &...
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Safety Symbols In this operator’s manual and on the product, safety symbols and signal words are used to communicate important safety information. This section is provided to improve understanding of these signal words and symbols.
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Service General Safety Rules • Pressure cleaner service must be performed only by qualified repair personnel. Service or maintenance WARNING performed by unqualified personnel could result in a risk of injury. Read and understand all instructions. Failure to follow •...
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER the risk of burns, fire, explosion or other injury. • Gasoline and its vapors are highly flammable and explosive. See engine manual for precautions to reduce the risk of burns, explosions and serious injury while handling and using gasoline.
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER The machine serial number is located on the frame. The first letter & digits indicate the year and month of the Make sure that the battery isolator and engine switch is manufacture. (G = 2021 (Year), 4 = April (Month)).
Check engine fuel level. If needed, add unleaded • Clear, level, stable dry place for machine and gasoline for Explorer G2 Petrol or add diesel for operator. Explorer G2D. Check burner fuel tank levels, add •...
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Water Supply Operating Instructions CAUTION According to the applicable regulation, the appliance must never be used on the drinking water supply without a system separator. Use a suitable system separator as per EN 12729 Type BA. Water flowing through a system separator is considered non-drinkable Run a hose from the water source to the unit water inlet.
3/4”. inconspicuous area to confirm the settings work as desired. Never direct the wash wand at people. High 6. Explorer G2 Petrol (Electric Key Start & Pull Start pressure fluid can inject under skin resulting in serious Backup) injury. Never direct wash wand at electrical equipment Move Fuel Valve to the ON position or wiring to reduce the risk of electrical shock.
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Hose Reel Brake Adjustment Battery The optional hose reel is equipped with an adjustable brake Safety notes regarding the battery to prevent the hose from playing off the reel under its own Please observe the following warning notes when handling weight.
At 1000 hours of use (less in severe use conditions) the Note: Before removing the battery, make sure the negative Explorer G2 should be taken to a Jetwave Independent pole lead is disconnected. Check that the battery pole and Service Center for pump seal and valve service.
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Service And Repair Declaration of Conformity We hereby declare that the machine described below WARNING complies with the relevant basic safety and health Improper service or repair can make machine unsafe requirements of the EU Directives listed below, both in its to operate.
Page 17
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Model Explorer G2 250-15 Explorer G2D 210-15 Explorer G2D 280-13 Product Code HW4000-15PG2 HW3000-15DG2 CW4000-13DG2 Motor Type Honda™ iGX390, single Kohler™ KD15-440, Kohler™ KD15-440, cylinder, 4-stroke OHV single cylinder single cylinder Maximum torque at 3600rpm kW/HP 8.7 / 11.7...
Page 18
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Honda™ Petrol iGX390 Engine Maintenance Schedule Based on the ‘Maintenance Schedule’ in the Honda™ Engine Manual, always refer to the included manual for more in depth safety, maintenance and operation procedures of the engine.
Page 19
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Kohler™ KD15-440 Diesel Air Cooled Engine Maintenance Schedule Based on the Maintenance section in the Kohler™ Engine Manual, always refer to the included manual for more in depth safety, maintenance and operation procedures of the engine.
Page 20
Refer to the included manual for your high pressure cleaner or water jetting system for safety, pre-inspection, operation, shutdown and more procedures. Always use an approved Jetwave™ servicing agent who uses Genuine Jetwave parts, to ensure full warranty coverage, service records will need to be provided.
Page 21
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Jetwave™ Hot Water Burner Assembly Maintenance Schedule Always use an approved Jetwave™ servicing agent who uses Genuine Jetwave parts, to ensure full warranty coverage, service records will need to be provided. REGULAR SERVICE PERIOD...
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Trouble Shooting FAULT CAUSE SOLUTION Pump runs normally Pump is sucking air. Check that all hoses and fittings are airtight. but pressure does not Valves are worn or dirty. Check, clean or replace.
EXPLORER G2 OPERATOR MANUAL - HIGH PRESSURE CLEANER Time interval for checks and replacement listed above are for units subjected to normal operating conditions. Should the unit be subjected to abnormal conditions (eg heavy use, dirty water, extreme temperatures or conditions etc) times should be reduced accordingly.
Need help?
Do you have a question about the EXPLORER G2 and is the answer not in the manual?