Bowers MOORE & WRIGHT MWT-2500 Operating Instructions Manual

Bowers MOORE & WRIGHT MWT-2500 Operating Instructions Manual

Ultrasonic thickness gauge

Advertisement

Quick Links

MWT-2500 Ultrasonic Thickness Gauge
Operating Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MOORE & WRIGHT MWT-2500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bowers MOORE & WRIGHT MWT-2500

  • Page 1 MWT-2500 Ultrasonic Thickness Gauge Operating Instructions...
  • Page 2: Table Of Contents

    2.16 Setting System Time 2.17 Setting Standby Time 2.18 Version Information Viewing 2.19 Thickness Value Storage, Viewing and Deletion 2.20 Backlight 2.21 Test Function 2.22 Shutdown Mode MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 3: Keypad

    Display Information time, etc • Measurement information can be stored, including thickness values, measured sound velocity and time Size 150mm x 71mm x 33mm Weight 200g MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 4: Testing And Operation

    Note: the probe frequency setting must be consistent with the probe frequency used, otherwise Measurement mode the measurement accuracy will be affected. Menu options System time Frozen result flag Unit Automatic storage flag MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 5: Velocity Adjustment

    * will be displayed as shown on the next page. Note: if the value displayed on the screen is not 4.00 after a successful calibration, please check whether the currently set sound speed is 5920. MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 6: Language Setting

    The thickness gauge has two measurement units, Metric and Imperial. To change units use the steps described in 2.6 to open the system settings, then use to select unit. MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 7: Setting Recovery Recognition Settings

    Press to select the setting to be adjusted, and press change the value. The date format is in year month day hour minute. MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 8: Backlight

    Then press to set the thickness of the measured material, and press to adjust the value. Press to save again and exit. MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 9: Shutdown Mode

    In most cases, satisfactory accuracy can be obtained by using only one reference block with the same material and similar thickness MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 10: Measurement Methods

    When used on rough material surfaces, or vertical surfaces and top surfaces, coupling agents with high viscosity (such as glycerin paste, butter, grease, etc.) can be used. MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 11: Precautions

    1920 water glass 2350 Note: the sound velocity in the above table is for reference only, and the actual sound velocity calibration refers to Section 3.1. MWT-2500 Ultrasonic Thickness Gauge Bowers Group | sales@bowersgroup.co.uk | www.bowersgroup.co.uk INST-MWT-2500 - Iss 1...
  • Page 12 MWT-2500 Ultrasonic Thickness Gauge INST-MWT-2500 - Iss 1...

Table of Contents