Floating Air Series ® Ductless Split Single Zone Indoor Wall-Mounted Unit R-32, R-454B Refrigerant Models Floating Air ® 115 VOLT FAHSW09A1A, FAHSW12A1A, Floating Air ® 208/230 VOLT FAHFW09A3A, FAHFW12A3A, FAHFW18A3A, FAHFW24A3A THE EXPERTS IN ROOM AIR CONDITIONING 96111101_02...
Register your Air Conditioner Model information can be found on the name plate. Please complete and mail the owner registration card furnished with this product, or register online at www.friedrich.com. A. IMPORTANT SAFETY AND GENERAL INFORMATION ....3 A.1 Introduction ................3 A.2 •...
A. IMPORTANT SAFETY AND GENERAL INFORMATION A.1 Introduction This booklet contains the installation and operating instructions for your Air Conditioning unit. There are some precautions that should be taken to ensure proper operation. Improper installation can result in unsatisfactory operation or dangerous conditions. Read this booklet and any instructions packaged with separate equipment required to make up the system prior to installation.
CAUTION: Do Not Operate Equipment During Active Stages Of Construction To ensure proper operation, Friedrich requires that all equipment is not operated during active construction phases. This includes active stages of completing framing, drywalling, spackling, sanding, painting, flooring, and moulding in the equipment’s designated conditioning space. The use of this equipment during construction could result in premature failure of the components and/or system and is in violation of our standard warranty guidelines.
• Opening of any sealed components. • Enclosures beyond the hinged door for filter cleaning. • Disposal or decommissioning of the unit. Scan this QR code to be linked to the Friedrich professional support page where you can locate the Service Manual.
C. INSTALLATION OF THE UNIT C.1 A2L Room size Restriction Minimum room size (R-32 or R-454B refrigerant) is determined by total refrigerant charge in system. Use this chart to determine the minimum room size the indoor head can be installed in. Height of installation(ft and inches) 6’...
C. INSTALLATION OF THE UNIT C.3 Pre-Installation Checkpoints 1. Ensure there are no obstacles near the air outlet and air can be easily blown to every corner. 2. Where piping and wall hole can be easily arranged. 3. Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page.
C. INSTALLATION OF THE UNIT Installation instructions / C.4 Install Mounting Plate Horizontal ruler Mounting plate position 1. Installing the Mounting Plate 1) Decide an installing location for the mounting plate Holder according to the indoor unit location and piping (for some models) ..
C. INSTALLATION OF THE UNIT C.4 Install Mounting Plate 8 in. or more to ceiling Indoor unit outline 2 in. or more ! 2 in. or more to wall i towall Pipe hole Pipe hole For 18K/ 24K Series Models, WIDTH: 37 5/ 38 in. C.
C. INSTALLATION OF THE UNIT Fig. C.5 C.6 Piping Provisions 3. Piping Provision 1) Put the piping (liquid and gas pipe) and cables through the wall hole from outside or put them through from inside after indoor piping and cables connection is complete to connect to the outdoor unit. 2) Decide whether to cut the knockout plate in accordance with the piping direction.
Cracked Uneven Thickness C. INSTALLATION OF THE UNIT Fig. C.6.5 Fig. C.6.4 Fig. C.7.1 C.7 Indoor Unit Installation 4. Indoor Unit Piping Installation 1) Hang the unit onto mounting plate Indoor unit installation (Fig. C.7.1). 2) In the A position, open the front panel as shown in Fig. C.7.2. 3) In the B position, open the screw covers as shown in Fig.
Page 12
Installation instructions / C. INSTALLATION OF THE UNIT C.7 Indoor Unit Installation Indoor unit installation 6) Connect the piping Piping Connection: Small sealing cap a.Before unscrewing the big and the small sealing caps, press the small sealing cap with the finger until the exhaust noise stops, and then loosen ' '9----.
Page 13
C. INSTALLATION OF THE UNIT ( Indoor unit installation C.7 Indoor Unit Installation The 18K/24K indoor unit include the switch tie-in accessory -..___ Gas valve only for 18K/24K indoor if required. It may switch 3/8" gas connection tube into 1/2" or 5/8" connection tube. ·.�...
Page 14
Installation instructions / C. INSTALLATION OF THE UNIT C.7 Indoor Unit Installation Indoor unit installation 10) Pull the baffles as shown in Fig. C.5.20 Close the front shell as shown in Fig. C.5.21 . Then press the E position to fasten the front shell as shown in Fig. C.5.22 Fig.
E. ELECTRICAL Model Wire Diameter(AWG) Interconnecting Wire WARNING 14-4 AWG 600V THHN 14-4 AWG 600V THHN 14-4 AWG 600V THHN Electrical Shock Hazard 24-36K 14-4 AWG 600V THHN Always ensure power is Table E.1 disconnected before attempting to connect wires. Installation Instructions, Power and Wiring Connecting of the Cable...
Present the owner or operator of the equipment with the Installation & Operation Manual, all accessory installation instructions, and the name, address, and telephone number of the Authorized Friedrich Warranty Service Company in the area for future reference if necessary. Inspect the unit for any damage to the coils and tubing that could cause a leak.
Page 19
ESPAÑOL El tamaño mínimo de la habitación (refrigerante R-32 o R-454B) está determinado por la carga total de refrigerante en el sistema. Utilice esta tabla para determinar el tamaño mínimo de la habitación en la que se puede instalar el cabezal interior. Un minuto (pies cuadra- Altura de instalación (pies y pulgadas) dos)
Page 21
ESPAÑOL lnstrucciones de seguridad • 1. Para garantizar que la unidad funcione con normalidad, lea atentamente el manual antes de realizar la instalacion y realicela en estricta conformidad con este manual. • 2. No deje que entre aire en el sistema de refrigeracion o descargue el refrigerante cuando traslade el climatizador.
Page 22
ESPAÑOL lnstrucciones de seguridad • 14. Si el aparato tiene cableado fijo, debe disponer de un media de desconexi6n de la alimentaci6n electrica con una separaci6n del contacto en todos los polos que proporcione una desconexi6n completa en condiciones de sobretensi6n de categoria y dichos medias deben estar incorporados en el cableado fijo de acuerdo con las normas de cableado.
Page 23
ESPAÑOL Preparaci6n antes de/ uso / Nota • Cuando cargue refrigerante en el sistema, asegurese de que este en estado liquido si el refrigerante del aparato es R32 y R454B. De lo contrario, la composici6n quimica del refrigerante (R32 y R454B) en el interior del sistema podria cambiar y afectar al rendimiento del climatizador.
Page 26
ESPAÑOL lnstrucciones de instalaci6n / Diagrama de instalaci6n La distancia respecto ')}. al techo debe ser La distancia respecto a '<J,. superior a 200 mmn,9 pulgadas. la pared debe ser <:y superior a 50 mm/2 pulgadas. La distancia respecto a la pared La distancia respecto a debe ser superior a 50 mm/2 los obstaculos debe ser...
Page 36
ESPAÑOL lnstrucciones de instalaci6n / Alimentaci6n y cableado Panel frontal Terminal (interior) Conectar el cable o Unidad interior Conecte el cable electrico con la unidad interior conectando individualmente los cables a los terminales del panel de control siguiendo la conexi6n de la unidad exterior.
Page 37
ESPAÑOL El diagrama es solo de referencia; se deben seguir los terminales reales del producto.
Page 49
FRANÇAIS La taille minimale de la pièce (réfrigérant R-32 ou R-454B) est déterminée par la charge totale de réfrigérant dans le système. Utilisez ce tableau pour déterminer la taille minimale de la pièce dans laquelle la tête intérieure peut être installée. Une minute (pieds Hauteur d’installation (pieds et pouces) carrés)
FRANÇAIS Instructions de securite • 1. Pour garantir que l'unite fonctionne normalement, veuillez lire soigneusement ce manuel avant !'installation, et essayez d'effectuer !'installation strictement en conformite avec ce manuel. • 2. Ne laissez pas d'air entrer dans le systeme de refrigeration ou le refrigerant se decharger lorsque vous deplacez le climatiseur.
Page 56
FRANÇAIS _ i n � n __ ...,/ Schema d'installation La distance depuis !'obstacle devrait etre La distance depuis superieure a 200 mm/7,9 pouces l'obstacle devrait etre pouces La distance depuis le mur La distance depuis l'obstacle devrait etre superieure a 3 devrait etre superieure a 50 m/9,8 pieds.
FRANÇAIS Instructions d'installation / Alimentation et cablage Panneau avant Terminal(interieur) Connexion du cable o Unite interieure Connectez le cordon d'alimentation a l'unite interieure en connectant les cables aux terminaux sur le panneau de controle de maniere individuelle conformement Unite interieure connexion de l'unite exterieure.
Page 67
FRANÇAIS Le diagramme est uniquement une référence, les bornes réelles du produit doivent être suivies.