Cellular (Amber LED) Good signal strength detected Bluetooth is off Bluetooth Bluetooth is in pairing mode FLASHING (Blue LED) Bluetooth is on Gateway Fault (Red LED) Gateway has no errors Table 2 Bosch IDS Gateway - BTC 762002302 A (08.2024)
Table 4 2.5 Connecting via Bluetooth Please see the Bosch EasyAir app for instructions on connecting your phone to the Gateway. On the Bosch EasyAir app, navigate to the “Unit Dashboard” and follow the instructions on the “System Data” tab.
When experiencing a gateway fault, the fi rst step is always to perform a Soft Reset on the gateway. If the issue is not resolved perform a Hard Reset followed by a Factory Reset as needed. (See “Resetting the Gateway”). Bosch IDS Gateway - BTC 762002302 A (08.2024)
3. Wait for 15 seconds. 4. Reconnect gateway at CN11 port. 5. Power unit ON 1. Power unit ON Factory Reset 2. Hold the “Factory” button on the gateway for at least 10 seconds. Table 7 Bosch IDS Gateway - BTC 762002302 A (08.2024)
3. Bluetooth LED 4. Fault LED 5. Factory (Diagnostic) Button 6. Connect (Bluetooth) Button 7. Reset Button The Gateway Assembly includes the Gateway and Antenna, along with associated wiring harness and clips. Bosch IDS Gateway - BTC 762002302 A (08.2024)
PRESS Last fault code FORCE (Charge mode) 4 blinks/cycle Hardware error Power on Software version LED3 PRESS Forced defrosting 5 blinks/cycle Cellular communication error Remark"--" Power off GREEN Figure 3 10 | Bosch IDS Gateway - BTC 762002302 A (08.2024)
Check the system parameters Factory code Date Revision Refrigerant amount judgment: significantly insufficient Reserved 16023000014172 Feb. 27th, 2024 Remark"--" Note: o31-o36 are only valid in force cooling mode. Figure 5 12 | Bosch IDS Gateway - BTC 762002302 A (08.2024)
Red LED turns on and stays on (1/2 second after Blue LED) gateway firmware update process. • All LEDs turn off (1/2 second after Red LED) • LED Sequence repeats until update completes Table 8 Bosch IDS Gateway - BTC 762002302 A (08.2024) | 13...