Quickstart
This is a secure CO Detector for Europe. To run this device please insert fresh 1 * CR123A batteries. Please make sure the internal battery is fully
charged.
1. Turn the cover counter-clockwise.
2. Take off the cover.
3. Remove the paper strip protecting the battery.
4. Proper powering up will be confirmed with a short beep.
5. Add the device (as described in "Adding/removing the device") if you want to use it in the Z-Wave network.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,
distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this
equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is
not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-
Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level
of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Product Description
FIBARO CO Sensor is an ultra-light, compact, battery-powered carbon monoxide detector, designed to be placed on a wall. Its high sensitivity allows to detect the
presence of the carbon monoxide (CO) gas at the early stage in order to prevent carbon monoxide poisoning. Alarm is signalled with a built-in siren, blinking LED
indicator and by sending commands to Z-Wave network devices. Additionally, the device is equipped with a temperature sensor.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do
this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended
to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1. Press and hold the button.
2. Release the button when LED indicator glows white.
3. Click the button when LED indicator glows yellow.
4. After few seconds the device will be reset (confirmed by red LED indicator).
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.

Advertisement

loading
Need help?

Need help?

Do you have a question about the FIBEFGCD-001 and is the answer not in the manual?

Questions and answers

Summary of Contents for FIBARO FIBEFGCD-001

  • Page 1 Product Description FIBARO CO Sensor is an ultra-light, compact, battery-powered carbon monoxide detector, designed to be placed on a wall. Its high sensitivity allows to detect the presence of the carbon monoxide (CO) gas at the early stage in order to prevent carbon monoxide poisoning. Alarm is signalled with a built-in siren, blinking LED indicator and by sending commands to Z-Wave network devices.
  • Page 2: Installation

    Installation READ BEFORE INSTALLATION AND HEED ALL THE WARNINGS! • The device should be installed below the ceiling level. • The device should be installed on the wall, at least 30 cm (1 ft) away from the corners. • The device should not be installed: in a bathroom, next to heat sources, within range of kids, obstructed from possible carbon monoxide sources, in direct sunlight.
  • Page 3 The CO Sensor is equipped with a LED diode and a buzzer, signalling menu position and status of the device. Checking battery level: FIBARO CO Sensor automatically warns about low battery with one yellow blink and a short beep, when battery level is low.
  • Page 4: Communication To A Sleeping Device (Wakeup)

    Communication to a Sleeping device (Wakeup) This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state.
  • Page 5 Setting Description all actions disabled tampering (opened casing) exceeding the temperature lack of Z-Wave range Parameter 4: Acoustic signals This parameter allows to set the actions which result in acoustic signals. This parameter does not apply to the most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
  • Page 6 Setting Description BASIC ON BASIC OFF BASIC ON & BASIC OFF Parameter 14: CO level required for sending BASIC ON command to 4th association group This parameter defines the minimum level of CO concentration which exceeding will result in starting the timer set in parameter 15. NOTE: Parameter 14 value must be at least 5 ppm higher than parameter 17 value.
  • Page 7: Technical Data

    Parameter 21: Temperature reporting hysteresis This parameter defines a minimum change in temperature resulting in a report being sent to the main Z-Wave controller. Size: 1 Byte, Default Value: 2 Setting Description 1 - 20 (0.5°C - 10°C, each 0.5°C) Parameter 22: Threshold of exceeding the temperature This parameter defines the temperature level, which exceeding will result in sending actions set in parameters 2, 3 and 4.
  • Page 8: Explanation Of Z-Wave Specific Terms

    Sensor Multilevel Crc 16 Encap Association Grp Info Device Reset Locally Zwaveplus Info Configuration Alarm Manufacturer Specific Powerlevel Firmware Update Md Battery Wake Up Association Version Multi Channel Association Security Sensor Alarm Explanation of Z-Wave specific terms Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.