Download Print this page

Advertisement

Quick Links

HermanMiller
Bay Installation Instructions
How to assemble your Bay
Tools Required
Driver
T25 Torx
driver bit
Allen keys
Panel Lifter
Card for
threshold
Knife
Safety Notes
PRODUCT ELECTRICAL RATING: 120 V 60 HZ 12 A
WARNING
Risk of Injury - maximum load 50 lb for worksurface, maxi-
:
mum load 20 lb for monitor mount
CEILING/ROOF: This surface is not designed for any type of load. Do not
put any objects on this surface.
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical furnishing, basic precautions should always
be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING.
DANGER: To reduce the risk of electrical shock:
1. Always unplug this furnishing from the electrical outlet before clean-
ing or servicing.
WARNING: To reduce the risk of burns, fire, electric shock, or injury to
persons:
HermanMiller Bay Installation
Extended
Drill bit 4mm
#2 Cross head
or 0.16"
driver bit
Level
Square
Spanner
Ladder
Parts Included
Panels
Door Hinges
Hub
Worktop & Brackets
User Power
AC Splitter
DC Power Supply
Occupancy indicator
(Optional)
1. Unplug from outlet before putting on or taking off parts.
2. Close supervision is necessary when this furnishing is used by, or
near children, invalids, or disabled persons.
3. Use this furnishing only for its intended use as described in these
instructions. Do not use attachments not recommended by the manu-
facturer.
4. Never operate this furnishing if it has a damaged cord or plug,
if it is not working properly, if it has been dropped or damaged, or
dropped into water. Return the furnishing to a service center for
examination and repair.
5. Keep the cord away from heated surfaces.
6. Never operate the furnishing with the air openings blocked. Keep
the air openings free of lint, hair, and the like.
7. Never drop or insert any object into any opening.
8. Do not use outdoors.
9. Do not operate where aerosol (spray) products are being used or
where oxygen is being administered.
10. To disconnect, turn all controls to the off position, then remove
plug from outlet.
1
1BXFRM rev B
Lintel
Threshold
Ventilation
Roof
Box
Door Handle
Monitor Plate &
Brackets(Optional)
Cable Tray
Dimmer
Assembly kit - Roof seal,
Threshold tape, Latch, Hinge
shims, P-clips, Screws
Assembly Instructions
Lights
Door

Advertisement

loading
Need help?

Need help?

Do you have a question about the Bay and is the answer not in the manual?

Questions and answers

Summary of Contents for HermanMiller Bay

  • Page 1 Parts Included HermanMiller Bay Installation Instructions Lintel Threshold Lights Ventilation Roof How to assemble your Bay Tools Required Panels Door Hinges Door Handle Monitor Plate & Driver T25 Torx Extended Drill bit 4mm Worktop & Brackets Brackets(Optional) driver bit #2 Cross head or 0.16”...
  • Page 2: Grounding Instructions

    WARNING: Risk of Electric Shock – Connect this furnishing to a properly IMPORTANT! grounded outlet only. See Grounding Instructions. Assembly of Bay Work Pod will require two people . If Seismic anchors are to be installed use the installation guide to SAVE THESE INSTRUCTIONS install the plates BEFORE the product is assembled.
  • Page 3 Standing height Seated height panel Monitor worktop bracket Location bracket Location Bottom of Seated height panel with Monitor glide bracket Location Standing height worktop bracket location Glide indicates bottom of panel HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 4 4.5 If putting down on hard floor leave backing on double sided tape. Peel just a small section of the backer (<1/2”) so it will be easier to access later. Apply tape to this face HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 5 Do not over tighten. slots in the door frame. see step2 for location. Note: Someone will need to support the panels until at least the first three panels are assembled. Tucked Corrugate HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 6 10.4 Feed AC power cord up the side of Tech panel inside wall. 10.5 Re-attach lower magnetic PET cover. AC power cord exits panel into cable tray through cut out in PET cover. PET Covers HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 7 11.1 Lower panel door post on to threshold tab. bottom connector to the mating panel. Do not disengage the 11.2 The tab fits into a slot in the same way as the first panel. panel from the threshold tab. 20mm/3/4” HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 8 See detail CAUTION: Do not overtighten screws to prevent stripping or cracking of the acrylic roof. Rim section with no holes Ventilation holes Seal HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 9 17.2 First push ends of lights into the extrusion and slightly under the end caps, and then work towards the centre pushing the light in to the extrusion. 17.3 Plug light cables into hub. HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 10 19.7 Adjust Tech panel tiles so that the gaps between the tile and 19.5 Plug cable into jack in ventilation box. adjacent panels on the left and right sides are equal. 19.6 Put PET cover back on Tech panel. HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 11 23.3 Connect door to bottom hinge and screw on interior plate to tighten to 20Nm (177lb-in) Or screw to snug fit plus 1/8 turn extra. 23.4 Tighten the upper hinge to 20Nm (177 lb-in) or snug plus 1/8 turn. HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 12 This may require lifting the unit for bet ter access. 26.3 Push the threshold down on to the floor. HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...
  • Page 13 Ferrous met- als can be identified using a small magnet for recycling. Non-ferrous metals should be separated and recycled separately. To disassemble product, reverse the above installation steps. HermanMiller Bay Installation 1BXFRM rev B Assembly Instructions...