The system comprises the Transmitter and the Breaker Finder (the Product). Contact Fluke Fluke Corporation operates worldwide. For local contact information, go to our website: www.fluke.com. To register your product, view, print, or download the latest manual or manual supplement, go to our website.
Page 3
SmartTrace Breaker Finder Product Use GFCI Test To test a GFCI: 1. Before you plug the Product into a GFCI socket, push the GFCI test button, if applicable, to trip the GFCI socket. If the GFCI does not trip, the socket is faulty and should be replaced.
Page 4
BK120 Users Guide Breaker and Fuse identification To identify a breaker: 1. Plug the Transmitter into the socket (See Figure 3.). Figure 3. Transmitter in socket 2. Turn ON the Breaker Finder and slide the function selector to BREAKER FINDER position (See Figure 4.). Figure 4.
Page 5
SmartTrace Breaker Finder Product Use 4. Repeat step 3 for the second scan, solid green indication illuminates when the Breaker Finder identifies the breaker that is powering the Transmitter (See Figure 6.). Figure 6. For optimal results or if the Breaker Finder detects two adjacent breakers on the second scan, reset the Breaker Finder, and turn the Breaker Finder 180⁰...
Page 6
BK120 Users Guide Non-contact voltage detection 1. Press momentarily to turn ON the Product. 2. Slide the switch to NCV position. 3. Put the tip of the Product near an AC voltage until the Product produces a steady glow (purple or red) at the tip and produces a continual single beep when at the AC voltage source (See Figure 9.).
SmartTrace Breaker Finder Maintenance Flashlight Push momentarily to turn ON the Product and flashlight at the tip is ON. Push momentarily again to turn OFF the flashlight (See Figure 13.). Figure 13. Flashlight Auto Power Off After about five minutes of nonuse, the Product automatically powers off to save battery life.
Figure 14. Battery Replacement Specifications General Safety Information is in the printed Safety Information document that shipped with the Product. More specific safety information is listed where applicable. Complete specifications are in the printed Safety Information and online at www.fluke.com.
Page 9
LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is two years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days.