Infrared Problems - HP OmniBook 7100 Reference Manual

Hp omnibook 7100: reference guide
Hide thumbs Also See for OmniBook 7100:
Table of Contents

Advertisement

Infrared Problems

If you have problems with infrared communications
Windows NT 4.0 does not support infrared devices.
Make sure the infrared light path is not blocked.
Line up the OmniBook's infrared port and the other infrared port in as straight a
line as possible. The two ports should be no more than 1 meter apart, with no
obstructions in between. Noise from nearby equipment can cause transmission
errors.
Press Fn+F to toggle between the front and rear OmniBook infrared ports.
Check settings in BIOS Setup utility.
1. From the Start menu, shut down, then restart the OmniBook.
2. When you see the HP logo, press F2 to enter the BIOS Setup utility.
3. From the System Devices menu, check that Infrared Port is enabled.
4. Check which infrared port you have enabled (front or rear port).
5. Press F10 to Save and Exit the BIOS Setup utility.
For infrared communications, an infrared driver must be installed and a BIOS
Setup setting must be enabled. See page 4-14.
Check that only one application is using the infrared port.
Standard IrDA and fast-IrDA are incompatible. They use different drivers.
For fast-IrDA, check for DMA conflict with ECP parallel port.
Remove any PC Cards. An infrared IRQ conflict is possible if two PC Cards are
plugged in at the same time.
If an infrared printer doesn't print
Make sure the infrared light path is not blocked.
An infrared driver must be installed and the BIOS Setup setting must be enabled.
For details, refer to the drivers' Readme files located in \OmniBook\Drivers.
In Windows Help, use the Print Troubleshooter.
Troubleshooting
7-7

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Omnibook 7150

Table of Contents