Table of Contents

Advertisement

Quick Links

Applied Model:
F08 H08
During the period due to product upgrades, there may be differences between the pictures and the actual products please refer to real
object.
Dr.coffee Service Manual
Technicup Service Manual
F08 & H08 Service manual
(Version:V00)
F08 & H08
Service Manual
(Version: V0.0)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F08 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dr.coffee F08

  • Page 1 F08 & H08 Service manual (Version:V00) F08 & H08 Service Manual (Version: V0.0) Applied Model:  F08 H08 During the period due to product upgrades, there may be differences between the pictures and the actual products please refer to real object.
  • Page 2: Table Of Contents

    Consumer Risky ........................................5 2.1.1 Machine Risky ........................................6 STRUCTURE ................................... 7 ............................................7 VERVIEW ......................................8 NTERNAL COMPONENTS OVERVIEW CIRCUIT OVERVIEW ................................10 F08 M ........................................10 AINBOARD CIRCUIT F08 S ........................................11 CREEN CIRCUIT SPECIFICATION ..................................12 ............................................12 APACITY ..........................................
  • Page 3 9.1.2 Brewer System Error ......................................32 9.1.3 HMI Communication Error ....................................32 9.1.4 Coffee Thermo-block NTC Error ..................................32 9.1.5 Coffee Thermo-block Heating Overtime ................................33 ..................................... 33 RROR WITHOUT IPS IN THE CREEN Dr.coffee Service Manual Technicup Service Manual...
  • Page 4 Disassemble water inlet valve .................................... 44 10.2.9 Disassemble grinder group ....................................45 10.2.10 Disassemble thermo-block ................................... 46 10.2.11 Disassemble control board ................................... 47 10.2.12 Disassemble front panel group ..................................48 DAILY USING AND MAINTENANCE ATTENTION ........................49 Dr.coffee Service Manual Technicup Service Manual...
  • Page 5: Safety Instructions

    Caution Drinks with additives or residues may cause allergies. Do follow below points: In self-service, check for possible allergenic products listed on the coffee machine;  In self-service, check for possible allergenic products with professional person.  Dr.coffee Service Manual Technicup Service Manual...
  • Page 6: Machine Risky

     Always use a new hose kit (drinking water/waste water hose) supplied with the machine, and do not use old hoses. Dr.coffee Service Manual Technicup Service Manual...
  • Page 7: Structure

    Rev 0.0 Structure Overview (F08 front view) Touch screen Water tank Coffee outlet Cup holder Drip tray (F08 Back side) Bean hopper Power socket Power switch Water supply switch Inlet water connection Dr.coffee Service Manual Technicup Service Manual...
  • Page 8: Internal Components Overview

    Rev 0.0 Internal components overview Coffee thermo-block Regulator valve Brewer motor group Pump Pressure valve Step motor Solenoid valve Transformer Front panel group Body support Brewer Pressure Release Valve Water Inlet Valve Group Flow meter Dr.coffee Service Manual Technicup Service Manual...
  • Page 9 Rev 0.0 Adjust gear Grinder Mainboard Transformer Waste Water Sensor Dr.coffee Service Manual Technicup Service Manual...
  • Page 10: Circuit Overview

    Rev 0.0 Circuit Overview F08 Mainboard circuit Pressure releasing step motor Flowmeter Power of drive motor Detective sensor of water tank Detective sensor of drip tray Hot water solenoid valve Power of fan Transformer AC 20V output line Power of grinder...
  • Page 11: F08 Screen Hmi Circuit

    Rev 0.0 F08 Screen HMI circuit Mainboard communication Display wire Touch wire USB transfer Dr.coffee Service Manual Technicup Service Manual...
  • Page 12: Specification

    Technical sheet Model Voltage(V) 220V~50Hz Power(W) 1450W Connection tube set inner diameter 5mm ,outer diameter9mm , Silicone Tube, length 1.5M Connection water pressure Without tap water Coffee machine W*D*H 340*500*430mm 300*500*430mm Coffee machine N.W 14kg Dr.coffee Service Manual Technicup Service Manual...
  • Page 13: Screenshot Description

    Screenshot description (When filter function is activated, button will be in the upper right corner) 1.Touch any picture to get coffee; (see details in the user manual) 2.Touch side button to change pages; (see details in the user manual) Dr.coffee Service Manual Technicup Service Manual...
  • Page 14: Shortcut Menu Bar

    Press “ Brewer Rinse” more than 3 seconds, enter to the “Brewer deep clean” (see details in the user manual) 6.2.2 Service Menu Touch“Service Menu” ,input password(details see below chapter)  Default password is 1609  Dr.coffee Service Manual Technicup Service Manual...
  • Page 15: Wipe Protect

    Tap “Confirm”, start rinsing automatically, screen turned off and power off (press more than 5 seconds to wake up machine) Tap “Return”, return to top level automatically. Service Menu Step 1: Tap “Service Menu” for entry Step 2: Input correct password Password:default password is 1609 Dr.coffee Service Manual Technicup Service Manual...
  • Page 16: Maintenance

    Water hardness 0-75ppm 76-150ppm 151-300ppm >300ppm Replace cycle 400L 300L 200L 100L For example Settled water hardness is 0-75ppm it means if the water  : : consumption reaches 400L, user must replace the filter. Dr.coffee Service Manual Technicup Service Manual...
  • Page 17: Water Draining

    Follow the instruction to finish this process. See details in User Manual  Drinks Setting 7.2.1 Drinks setting Drinks setting Can modify the parameters of any beverage Dr.coffee Service Manual Technicup Service Manual...
  • Page 18: Grounds

    Test after modifying any parameter, click the "Test" button to make a drink according to the drink parameter value displayed on the current interface Save after all parameters are modified, click the "Save" button to save Dr.coffee Service Manual Technicup Service Manual...
  • Page 19: Drinks Lock

    After locking the drinks exit back to main menu, the drinks icon disappeared.  7.2.3 Position Change Positon change:Touch any two drinks icons, position changes, save the data. Machine Setting Machine setting:Set the condition values for various maintenance intervals of the machine. Tap “Save” to effect Dr.coffee Service Manual Technicup Service Manual...
  • Page 20: Language Setting

    Default setting 1000 , after the coffee machine has made 1000  : “ ” cups of drinks, the machine will automatically prompt you to use the tablets for deep cleaning of the brewing system. Dr.coffee Service Manual Technicup Service Manual...
  • Page 21 1250cups,the machine will prompt to do descaling. Three periodic conditions, when any one of them is reached, prompt to do descaling. After the required descaling operation, all conditions are reset and cleared, and then the ※ calculation is restarted. Dr.coffee Service Manual Technicup Service Manual...
  • Page 22: Auto Power Off

    ECO:After standing by after 1 hour, the temperature of Hot water Thermo- block will low down to be 60 and keep status ℃ 。 7.3.5 Unit Setting Unit:Different units can be selected as needed. Tap “Save” to effect. Select range: ml, oz Dr.coffee Service Manual Technicup Service Manual...
  • Page 23: Password

    (default: open) If this function is turned off, the “+” and “-” used to adjust the amount will be  grayed out in the beverage making interface, and it will be invalid when clicked. Dr.coffee Service Manual Technicup Service Manual...
  • Page 24: Eng. Setting

    (Enter the value as an integer, round to the nearest decimal point) Fifth step:After the above steps are cycled 3 times Sixth step: The “Save” button will appear on the interface, and all the steps of calibration will be completed after clicking. Dr.coffee Service Manual Technicup Service Manual...
  • Page 25: Grinding Index

    After clicking the button next to “Eng. setting reset”, you can save the parameters after saving and restarting the coffee machine. Factory reset After clicking the button next to “Factory reset”, you can save the parameters after saving and restarting the coffee machine. Dr.coffee Service Manual Technicup Service Manual...
  • Page 26: Information

    7.5.3 Soft. Version Info. Mainboard version: Shows the coffee machines mainboard version HMI Version: Shows the coffee machines HMI version Machine S/N: Shows coffee machine tracking no. Dr.coffee Service Manual Technicup Service Manual...
  • Page 27: Warning

    Showing on the Screen Cause Solutions Bean Fill coffee beans to the bean box;  coffee bean hopper is empty; Hopper Stir the beans in the bopper until they are  Beans sticks together; Empty loose; Dr.coffee Service Manual Technicup Service Manual...
  • Page 28: Drip Tray Is Not In Place

    Wait, as the tips in the Screen “The hot  Thermo- water thermos-block is cooling down, Block Temperature is over 160℃; please wait ...”; Over-he While the thermos-block is cooling down,  ated no beverage could be made. Dr.coffee Service Manual Technicup Service Manual...
  • Page 29: Environment Temp. Is Too Low

    If water supplied by tank, clean the Inlet  Air is coming into the Pump while coffee of tank; If water supplied by tap water, making; check if there is water available, or the connector is loosed; Dr.coffee Service Manual Technicup Service Manual...
  • Page 30: Grinder Calibration

    Follow the tips and enter service manual  Deep Manu; to do deep clean; Clean The settled valve can be changed  Follow the instructions of service manual  Required in the service manual; Dr.coffee Service Manual Technicup Service Manual...
  • Page 31: Descaling Required

    Re-fix the tank. Push it to the end;;  Error Clean the strainer by Brewer Deep Clean  with tablets or by dissembling; Replace a new Pump;  Replace a new Flow meter;  Dr.coffee Service Manual Technicup Service Manual...
  • Page 32: Brewer System Error

    Replace new NTC sensor;  block Electronic fault between sensor and Turn off machine and wait for 30 minutes,  master turn on again; Sensor damaged; Replace new thermos-block group.  Error Dr.coffee Service Manual Technicup Service Manual...
  • Page 33: Coffee Thermo-Block Heating Overtime

    Do Brewer Deep Rinse with tablets;  The Brewer damages; Re-fix the Brewer, or replace a new  The Strainer of inlet valve is blocked; Brewer; Clean Strainer or replace a new one;  Dr.coffee Service Manual Technicup Service Manual...
  • Page 34: Software System Crashed

    Leaking at the inlet connector of machine Dissemble the cover of machine and find  Leaking No picture to Tap water ; out the place leaking; Leaking inside of machine; Replace the parts leaking;  Dr.coffee Service Manual Technicup Service Manual...
  • Page 35: Disassembly & Assembly

    Rev 0.0 10 Disassembly & Assembly 10.1 Tools Screwdriver (T10) Screwdriver (T20) Millimeter Flat Screwdriver (3.2mm) Thermometer Electronic scale Long nose pliers Dr.coffee Service Manual Technicup Service Manual...
  • Page 36: General Disassembly

    Step1: First open the water tank cover as shown in the figure, remove the large water tank upwards, and then remove a fixing screw at the marked position of the red circle; Step 2: Hold the base and take out the tank base downward. Remove the tank base Attention: ★ 1、Handle gently during disassembly to prevent scratching! Dr.coffee Service Manual Technicup Service Manual...
  • Page 37: Disassemble Front Panel

    Step2:Use a flat-blade screwdriver to press (as shown in Figure 1 to Figure 5) the buckle at the position indicated by the red arrow to release the buckle at these five positions. Attention: ★ 1、Handle gently during disassembly to prevent scratching! Dr.coffee Service Manual Technicup Service Manual...
  • Page 38: Disassemble Rear Panel

    First push the left side panel fro Step 2:First push up the right side plate, then pull back the right side plate and remove, remove the right side plate complete. Attention: ★ 1、Handle gently during disassembly to prevent scratching! Dr.coffee Service Manual Technicup Service Manual...
  • Page 39: Disassemble Brew Unit

    Attention: ★ 1、 Please disassemble the machine after it has cooled down to prevent burns! 2、 In the process of disassembly, you can use both hands to take care of it, beware of bruises! Dr.coffee Service Manual Technicup Service Manual...
  • Page 40: Disassemble Pressure Releasing Valve

    Step3:Grasp the pressure relief valve block with your hand and pull out the pressure relief valve group in the direction indicated by the arrow (Figure 1). Disassemble the group. Attention: ★ 1、Unplug the coffee machine before doing this! Dr.coffee Service Manual Technicup Service Manual...
  • Page 41: Disassemble Brew Motor Group

    Step 2: Use screwdriver T20 to remove two fixing screws (marked in red as shown in figure 2), grab brew motor group and take out of it. Attention: ★ 1、 Be careful during the disassembly process to prevent scratching your fingers! 2、 Unplug the coffee machine before doing this! Dr.coffee Service Manual Technicup Service Manual...
  • Page 42: Disassemble Solenoid Valve

    Remark: Solenoid valve connects "water inlet" and "water outlet" in different directions (as shown in Figure 6) “2”means connect “water outlet” “1”means connect “water inlet” Attention: ★ 1、Be careful during the disassembly process to prevent scratching your fingers! Dr.coffee Service Manual Technicup Service Manual...
  • Page 43: Disassemble Pump

    Step2:According to the position shown by the arrow), pull out the silicone water pipe connected to the pump, and finally take out the pump set and remove the pump set. Attention: ★ 1、Be careful during the disassembly process to prevent scratching your fingers! Dr.coffee Service Manual Technicup Service Manual...
  • Page 44: Disassemble Flowmeter

    撬开此处 Attention: ★ 1、 Be careful during the disassembly process to prevent scratching your fingers! 2、 There may be residual water in the pipe. Please prepare the water container in advance! Dr.coffee Service Manual Technicup Service Manual...
  • Page 45: Disassemble Grinder Group

    Step2: Grab the parts of the grinder by hand, take out the whole grinder group upwards, and disassemble the grinder group. Attention: 1、Switch off the machine before disassembling! 2、Before removing the grinder group, please empty the residual coffee beans and coffee powder in the grinder! Dr.coffee Service Manual Technicup Service Manual...
  • Page 46: Disassemble Thermo-Block

    1、Unplug the coffee machine before doing this! 2、There may be residual water in the pipe. Please prepare the water container in advance! 3、Please disassemble the coffee machine after it has cooled down completely, beware of burns! Dr.coffee Service Manual Technicup Service Manual...
  • Page 47: Disassemble Control Board

    Attention: ★ 1、Unplug the coffee machine before doing this! 2、When pulling the cable plug, please press the buckle first and then pull the plug to prevent the terminal from being broken! Dr.coffee Service Manual Technicup Service Manual...
  • Page 48: Disassemble Front Panel Group

    Step3:(Figure 1, 2) Grab the front panel group with both hands, pull out the entire assembly forcefully, remove the front panel group to complete. Attention: ★ 1、The display is made of glass. Please take it lightly during the disassembly process to prevent the glass from breaking! Dr.coffee Service Manual Technicup Service Manual...
  • Page 49: Daily Using And Maintenance Attention

    To ensure the quality of the coffee, it is recommended to clean the water tank daily and replace the water in the water tank; If you use tap water, do not use the machine after the external water source is stopped Dr.coffee Service Manual Technicup Service Manual...
  • Page 50 苏 州 咖 博 士 咖 啡 系 统 科 技 有 限 公 司 Tel. +32 51 58 38 58 地址:中国 江苏 苏州高新区泰山路 599 号 3#楼 3 楼 info@technicup.be 邮编:215163 www.technicup.be 热线:400-897-7711 网址:www.dr-coffee.com Dr.coffee Service Manual Technicup Service Manual...

This manual is also suitable for:

H08

Table of Contents