8- Programming and managing options
Any safety devices (Photocells or Stop) must be
N.B.
connected before programming,
otherwise, these are NOT active.
8.1 – INTIAL SETUP
Press and hold button B; after 5" the icon
the button pressed the door opens; release the button when the desired point is
reached and confirm the position pressin button A; now press and hold down
button B again, the door closes
is reached and confirm the position with button A; then the [-] comes on to
indicate that the automation is ready to work.
Once programming is complete, button B becomes a STEP-BY-STEP command if
pressed in impulsive mode.
Limit switch – Opening phase
A
5"
Push
B
Limit switch – Closing phase
A
Push
B
8.2 – Remote control learning – Total opening
Press and hold button A, after 5" the icon [A] lights up on the display; release the
button and press the key on the fob to be programmed within 5"; the correct procedure
is highlighted by a flashing of the display; after a few seconds the [-] lights up to
indicate that the automation is ready to work.
Repeat the operation to program other fob transmitters.
A
Push
5"
B
P.12
A
Push
B
Close
Push
flashes on the display; keeping
, release the button when the desired point
Open
Push
Stop
A
B
Push
Stop
A
B
A
B
A
B
A
B