Page 1
This Owner's Manual is provided and hosted by Appliance Factory Parts. SEA BREEZE WA12YR Owner's Manual Shop genuine replacement parts for SEA BREEZE WA12YR Find Your SEA BREEZE Air Conditioner Parts - Select From 23 Models -------- Manual continues below --------...
TABLE OF CONTENTS AIR CONDITIONER SAFETY………………………………………………….….2 INSTALLATION REQUIREMENTS………………………………………………3 ELECTRICAL REQUIREMENTS…………………………………………………4 INSTALLATION INSTRUCTIONS………………………………………………..6 THRU-WALL INSTALLATION INSTRUCTIONS………………………………10 AIR CONDITIONER USE…………………………………………………………12 AIR CONDITIONER CARE……………………………………………………….16 TROUBLESHOOTING………………………………………………………….…16 SPECIFICATIONS…………………………………………………………………18 WARRANTY………………………………………………………………………...19 TECHNICAL SUPPORT IF YOU NEED TECHNICAL SUPPORT, PLEASE CALL (705) 504-8590 BETWEEN THE HOURS OF 8:00 A.M. and 5:00 P.M.
IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock, or injury when using your air conditioner, follow these basic precautions: • • Plug into a grounded 3 prong outlet. Do not use an extension cord • • Do not remove ground prong Unplug air conditioner before servicing •...
ELECTRICAL REQUIREMENTS Window Installation Window opening measurements: • 27” min to 38” max (68.6 cm to 95.5cm) opening width. • 16 ¼” min. (41.3 cm) opening height. Ground wire must be connected to ground screw located in lower Through-the wall installation right corner of air conditioner when air conditioner is in cabinet.
Page 6
This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances.
INSTALLATION INSTRUCTIONS UNPACKING Remove front panel by removing 2 Phillips head screws on both sides of air conditioner. Remove both knobs from control panel Remove ground screw and ground wire from front of air conditioner base. Save ground screw. Remove packaging materials •...
Page 8
Attach Side Curtains Attach Foam Adhesive Seal ______________________________________________ _______________________________________________________ Locate provided bag of screws Attach foam adhesive seal along the bottom of the curtain bottom Insert top and bottom of right-hand curtain housing in channel. top and bottom curtain guides on air-conditioner cabinet.
Page 9
Use a 3/16” drill bit to drill 3 starter holes 3/8” deep Insert one of the #10 x ¾” round-head screws through hole through the 3 holes in the cabinet and into the windowsill. and into lower window sash. Insert one of the #10 x ¾” round-head screws through threaded hole in top of curtain.
Page 10
______________________________________________________________________________________________________________________ Complete Installation NOTE: Handle the air conditioner gently. Position ground wire pointing straight up. Put excess ground wire between coil and air conditioner cabinet Make sure the free end of the ground wire is outside of the cabinet. Insert air conditioner into cabinet. REMEMBER: Make sure the free end of the ground wire is Remove the 2 front panel screws from air conditioner outside of the cabinet.
__________________________________________________________________________________________________________________ THRU-WALL INSTALLATION INSTRUCTIONS INTRODUCTION This instruction sheet provides guidelines for installing a compact air conditioner through an outside wall. Air Conditioner Dimensions The following figures show the outside dimensions of air conditioner with chassis installed, and dimensions of the outer case with the chassis removed which need to be measured accurately to determine the size of the opening through the wall.
Page 12
Framed/Finished Opening (brick veneer or frame wall construction) While operation of all units is similar, controls very from model Placement of Outer Case in Opening to model. Operating Controls section shows control panel of unit Place outer case in opening, flush against one side of opening. purchased and gives detailed information about controls.
Power Saver – The fan runs only when cooling is needed. You can select the fan speed by pressing Fan Speed. Model WA12YR NOTES: Because the fan does not circulate the room air continuously, less energy is used, but the room air is not When the air conditioner is off, the display shows the circulated as often.
Page 14
To set the timer to turn on the air conditioner, changing the _______________________________________________________ TEMPERATURE previous settings: _______________________________________________________ 1. Turn on air conditioner. Press the plus button to raise the temperature. Display shows the temperature control setting. Each time you press or hold the plus 2.
Page 15
NOTE: Two AAA batteries (included) power the remote control. Replace the batteries after 6 months of use, or when the remote control starts to loose power. To set Timer for a 1- to 24-hour delay before air conditioner is turned off (air conditioner must be on): 1.
Page 16
______________________________________________________ _______________________________________________________ FAN SPEED TEMPERATURE _______________________________________________________ _______________________________________________________ Set FAN SPEED to the desired setting. When the air conditioner is operating at Low Cool, High Cool (on some models), Med Cool (on Turn the TEMPERATURE control to a mid-setting. Adjust the air some models), or Turbo Cool (on some models), the fan circulates conditioner’s performance by turning the Temperature control air continuously.
______________________________________________________________________________________________________________________ AIR CONDITIONER CARE _______________________________________________________ Cleaning the Front Panel Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly. Call your local authorized dealer for an 1.
Page 18
You are trying to restart the air conditioner too soon after turning the unit off. Wait at least 3 minutes after turning the unit off The inside evaporator and outside condenser coils are dirty or obstructed by debris. See Annual Maintenance. before trying to restart the air conditioner.
WARRANTY International Refrigeration Products warrants that the product supplied is free from defects in material and workmanship. This warranty is valid as long as this product is properly handled, installed, operated and serviced in accordance with the Installation and Operating Instructions shipped with this unit, and the warranty card is completed and mailed no later than 30 days after date of purchase.
Need help?
Do you have a question about the WA12YR and is the answer not in the manual?