RIB K400 Manual
Hide thumbs Also See for K400:

Advertisement

Quick Links

K400
‫رسومات فنية للمشروعات‬
Technical drawings for projects
‫عامل‬
Operator
K400
‫ / مع‬with
‫مزود الطاقة‬
‫ماكس بوابة الوزن‬
Power Supply
Max gate weight
230V 50/60Hz
400 kg / 881 lbs
120V 60Hz
RIB ‫يتم ضمان التشغيل الصحيح للمشغل فقط في حالة إدارته بواسطة لوحة تحكم‬
The correct operation of the operator is guaranteed only if it is managed by a RIB control panel
3 ‫ / الصفحة العربية‬ENGLISH page 5
L1 24V-CRX
See page 17
‫أقصى قوة دفع‬
‫االنفعال االقصى‬
Max Thrust
Max torque
434 N
‫الشفرة‬
Code
AA40928
14,7 Nm
AA40929

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K400 and is the answer not in the manual?

Questions and answers

Summary of Contents for RIB K400

  • Page 1 120V 60Hz AA40929 RIB ‫يتم ضمان التشغيل الصحيح للمشغل فقط في حالة إدارته بواسطة لوحة تحكم‬ The correct operation of the operator is guaranteed only if it is managed by a RIB control panel 3 ‫ / الصفحة العربية‬ENGLISH page 5...
  • Page 2 ‫ الحد األدنى و‬sqmm 1،5 ‫ مع‬H05RN -F ‫ برقية نوع‬RIB ‫2 ° - لل قسم ونوع من النصائح الستخدام الكابالت‬ 3° - Positioning of a possible couple of photoelectric cells: the radius of the photoelectric cells .‫...
  • Page 3 .‫اسحب ال ر افعة لفتح املشغل‬ .‫اخترب نقطة التدخل الخاصة بالكامات عن طريق تحريك البوابة يف اتجاه الفتح والغلق‬ .‫) الكامات‬K400 FCM( ‫ تنطفئ عندما يكتشف الحساس‬DL5 ‫ و‬DL4 ‫ملحوظة: الليد‬ .‫ضع البوابة يف منتصف املسار وأعد إغالق املشغل‬ K400 FCM...
  • Page 4 K400 ‫ لـ‬DIP 15-16 OFF ‫يجب أن تبقى‬ .L1 24V ‫ لالستفادة من جميع الوظائف املتقدمة التي ميكن أن يقدمها لك مجلس‬RIB GATE App ‫+ مع وحداتها) واستخدام هاتفك الذيك مع تطبيق‬APP ‫ (أو بطاقة‬APP ‫تنبيه: • قم بتثبيت بطاقة‬...
  • Page 5 SIMPLIFIED INSTRUCTIONS FOR K400 WITH L1 24V-CRX 1° Connecting the accessories MANUAL RELEASE L.S. OPEN SAFETY AND CLOSE ENCODER 24 Vdc 20 W 24 Vdc 3 W COMMON A+TEST / A- 24Vdc 0,5A ±15% PHOTOCELL AUTO-TEST OR ENERGY SAVING (LOW BATTERY) WITH BATTERY 24Vdc 0,5A ±15%...
  • Page 6 DIP 15-16 must remain OFF for K400 ATTENTION: Install the APP card (or the APP+ card with its modules) and use your smartphone with the RIB GATE App to take advantage of all the advanced features that the L1 24V control board...
  • Page 7: System Layout

    SYSTEM LAY-OUT 1 - K400 operating device 2 - External photocells 3 - Rack of Module 4 4 - Key selector 5 - Radio antenna 6 - Blinker 7 - Limit switch plate (cams) 8 - Mechanical strip 9 - Mechanical strip...
  • Page 8: Command Type

    INSTALLATION K400 CHECKING BEFORE THE INSTALLATION !! THE GATE SHALL MOVE FRICTIONLESS !! N.B.: Gate features must be uniformed with the standards and laws in force. The door/gate can be automated only if it is in a good condition and its conditions comply with the EN 12604 norm.
  • Page 9 Such adjustment proves to be useful to set a 1mm clearance between the drive gear and the rack. Insert the two 4MA self-locking nuts which are needed to fix the cover of the K400 operator before securing the operator to its base plate using the nuts and flat washers 8MA 8x26 provided (see Pict.
  • Page 10: Electric Connections

    MAINTENANCE REMOVE THE TRANSPARENT COVER FROM THE TOP OF THE ELECTRONIC To be carried out exclusively by skilled persons after the power supply to the motor has BOARD BY UNSCREWING ITS 3 SCREWS. been interrupted. Periodically, when the gate is standstill, clean and keep the guide free from stones and dirt. ELECTRIC CONNECTIONS L1 24V cod.
  • Page 11 DIP 16 DIP 2 PROGRAMME FULL OPENING (POINT D) DIP 2-1 PROGRAMME PEDESTRIAN OPENING TIMES (POINT E) K400 DIP 1-2 SAVE/DELETE RADIO CODES FOR FULL OPENING CONTROL (POINT F) DIP 1-3 SAVE/DELETE RADIO CODES FOR PEDESTRIAN OPENING CONTROL (POINT G)
  • Page 12 GRADUAL BRAKING programming procedure must be repeated. DIP 10 ON =>Brake activated. With the RIB GATE app it is possible to regulate braking making Note: the low speed starting point is calculated automatically by the control unit during the it gradual.
  • Page 13 The 10 s for programming the codes are automatically renewed, with LED Through the RIB GATE app it is possible to configure the operation of this relay as desired. DL12 which flashes red, in order to store the next transmitter.
  • Page 14: Operation Of Safety Devices

    DIP 6 ON = > it runs a cyclical command sequence open-stop-close-stop-open etc. STOP BUTTON (COM A+/STOP) - Safety function PL “b” according to EN13849-1 DIP 6 OFF = > it opens the closed gate. If operated while the gate is opening, the button has no During the movement, the stop button will stop the gate.
  • Page 15: Troubleshooting

    - All inputs must be used as clean contacts because the power is generated internally (secure power) to the board and is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage. - Any external circuits connected to the outputs of the control panel must be made in such a manner as to ensure compliance with double or reinforced insulation with regard to dangerous voltage.
  • Page 16 TABLE SUMMARISING VISUAL AND SOUND ALARMS SIGNALS DURING PROGRAMMING SEQUENCE EVENT BUZZER STATUS FLASHER STATUS DL1 LED STATUS DIP 1 ON (hold-to-run mode) Flashes ON/OFF 250 ms Or failure of a safety device DIP 2 ON (full stroke programming) Flashes ON/OFF 500 ms DIP 2 ON >...
  • Page 17 ACCESSORIES For the connections and the technical data of the optional equipments follow the relevant handbooks. BATTERIES CHARGER CARD SAIL 102.5 47.5 SAIL orange with built-in flashing board code ACG7072 SAIL white with built-in flashing board code ACG7078 code ACG4776 SAIL LATERAL SUPPORT code ACG8054 RADIO TRANSMITTER SUN...
  • Page 18 PHOTOCELLS CONNECTIONS 4 FIT SLIM / FIT SYNCRO photocells with self-test and infrared signal synchronizer 2 photocells FIT SLIM, FIT SYNCRO with self-test COM A+ TX SYNCRO A+ TEST COM A+ PHOT1 PHOT2 cod. ACG8028 A+ TEST PHOT1 PHOT2 cod. ACG8029 A*D+ A*D+ A*D+...
  • Page 19 VITE TCEI 5,5X16 AUTOF. ZINC. CME2154 INGR. ACCIAIO K800/K1400/K2200 CTC1442 MOLLA LEVA SBLOCCO K400 24V DTB55X38 VITE TCEI 5,5X38 AUT.ZINC.C15 CME2178 BOCCOLA X LEVA SBLOCCO K400 24 CTC1443 MOLLA PERNO SBLOCCO K400 24V DTB6X20I VITE TCEI 6X20 INOX CME2179 PERNO SBLOCCO K400 24V CTC1444...
  • Page 20: Made In Italy

    Declaration of incorporation for partly completed machinery - Machinery Directive 2006/42/EC, Annex II., B R.I.B. S.r.l. - Via Matteotti, 162 - 25014 Castenedolo - Brescia - Italy Tel. ++39.030.2135811 - www.ribind.it - ribind@ribind.it K400 :‫موديل الجهاز‬ :‫الغرض من اإلقرار‬ Apparatus model :...

This manual is also suitable for:

Aa40928Aa40929