Advertisement

Quick Links

BML Island
BML-E30CG, BML-E36CG
EN Use, Care, and Installation Guide
FR Guide d'utilisation, d'entretien et d'installation
Register Your Product Today
zephyronline.com/registration
SEP24.0101

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BML Island and is the answer not in the manual?

Questions and answers

Summary of Contents for Zephyr BML Island

  • Page 1 BML Island BML-E30CG, BML-E36CG EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation Register Your Product Today zephyronline.com/registration SEP24.0101...
  • Page 2 B R I S A S B M L I S L A N D BML-C Use, Care, and Installation Guide...
  • Page 3: Table Of Contents

    Contents Page Safety Information ................4-6 Types of Safety Warnings ..............4 General Safety ..................4-5 Operation ................... 5 Electrical Requirements ..............6 Federal Communication Commission Interface Statement ....6 List of Materials ................... 7 Installation Instructions ..............8-17 Ducting Calculation Sheet ..............8 Mounting Height, Clearance, &...
  • Page 4: Safety Information

    B R I S A S Safety Information B M L I S L A N D READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. WARNING We have provided many important safety messages in this manual for your appliance.
  • Page 5: Operation

    Safety Information READ AND SAVE THESE INSTRUCTIONS WARNING WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and...
  • Page 6: Electrical Requirements

    B R I S A S Safety Information B M L I S L A N D READ AND SAVE THESE INSTRUCTIONS Electrical Requirements Important: ► Observe all governing codes and ordinances. ► It is the customer’s responsibility to be aware of these below: ►...
  • Page 7: List Of Materials

    List of Materials PARTS SUPPLIED 1 - Top support frame 2 - Top duct covers Front of Hood Cut-Out Shaded Area 1 - Paper ceiling template 2 - Bottom duct covers 1 - Bottom support frame 1 - 6” round damper (pre-installed) 1 - Hood body w/ blower (pre-installed) 1 - Hardware package 1 - Canopy, glass...
  • Page 8: Installation Instructions

    B R I S A S Installation Instructions B M L I S L A N D Ducting Calculation Sheet Equivalent number Equivalent number Duct pieces Duct pieces length x used Total length x used Total 3- 1/ 4” x 10” 1 Ft.
  • Page 9: Mounting Height, Clearance, & Ducting

    Installation Instructions Mounting Height, Clearance, & Ducting i n . ” m ” m ” Standard Extension Duct Cover Duct Cover Hood Heights minimum (A) 28” 48” min. recirc. (B) 28” 48” maximum (C) 36-1/2” 75” Ceiling Heights minimum (D) 88”...
  • Page 10 B R I S A S Installation Instructions B M L I S L A N D Mounting Height, Clearance, & Ducting A minimum of 6” round duct is recommended to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use the ducting calculation sheet (on page 8) to compute total available duct run when using elbows, transitions and caps.
  • Page 11: Ducting Options

    Installation Instructions Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. ► Use single wall rigid metal ductwork only. ►...
  • Page 12: Hood Specifications

    B R I S A S Installation Instructions B M L I S L A N D Hood Specifications ” ” 7/16 Standard Min. ducted: 28” Min. recirc.: 28“ Max. ducted: 36- ” B1C-00ML Min. ducted: 48” Min. recirc.: 48” ”...
  • Page 13: Electrical Supply

    Installation Instructions Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
  • Page 14: Mounting The Hood

    B R I S A S Installation Instructions B M L I S L A N D Mounting the Hood CAUTION Front of Hood Hood is intended to be mounted to a finished Cut-Out Shaded Area ceiling. Ceiling Preparation 1. Determine hood mounting location and temporarily tape paper template (included with the hood) to the ceiling.
  • Page 15 Installation Instructions Mounting the Hood 7. Lift support frame assembly up to the ceiling making sure the word “front” on the top support frame faces the front of the hood where the controls will be located (FIG. D). The key-holes on the top support frame should cover the wood screws previously installed in the ceiling.
  • Page 16 B R I S A S Installation Instructions B M L I S L A N D Mounting the Hood Top Support Frame Top Duct Covers Bottom Duct Covers Bottom Support Frame FIG. G 13. Assemble top duct covers (with louver holes) together over top support frame, secure top duct covers together by magnetic strips.
  • Page 17: Ductless Recirculation

    Installation Instructions Ductless Recirculation Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.
  • Page 18: Features & Controls

    B R I S A S Features & Controls B M L I S L A N D Electronic Touch 1. POWER BUTTON ► The POWER button will turn the power on and off for the entire hood (fan and lights). The hood has a memory function and will remember the last speed and light level it was turned off at.
  • Page 19: Maintenance

    Maintenance Hood & Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ► Do not use any product containing chlorine bleach or any product containing chloride. ► Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth.
  • Page 20: Led Light Replacement

    B R I S A S Maintenance B M L I S L A N D Installing the Grease Filters (FIG. I): 1. Pull down on filter latch to release the filter tabs. 2. Pull down on front of filter to remove the grease filters. FIG.
  • Page 21: Cfm Selector Conversion

    CFM Selector Conversion CFM Selector Some local codes limit the maximum amount of CFM a range hood can move. CFM Selector allows you to control the maximum blower CFM without the need for expensive make up air kits. CFM Selector enables the installer to easily set the maximum blower speed to the CFM level, 290 CFM. The usage of CFM Selector may not be necessary for your installation.
  • Page 22: Enabling Cfm Selector

    B R I S A S CFM Selector Conversion B M L I S L A N D Enabling CFM Selector To enable CFM Selector: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. K. 2.
  • Page 23: Wiring Diagram

    Wiring Diagram Power consumption shown for default CFM blower configuration BML - Max: 3A, 390 CFM: 2.1A, 290 CFM: 1.8A BML-C Use, Care, and Installation Guide...
  • Page 24: Troubleshooting

    B R I S A S Troubleshooting B M L I S L A N D Possible Problem Possible Cause Solutions After installation, the The power source is not turned ON. Make sure the circuit breaker and the unit’s unit doesn’t work. power is ON.
  • Page 25 Troubleshooting Possible Problem Possible Cause Solutions The hood is not venting Using the wrong size of ducting. Change the ducting to the correct size. out properly. The hood might be hanging to high Adjust the distance between the cook top from the cook top.
  • Page 26: List Of Parts & Accessories

    B R I S A S List of Parts & Accessories B M L I S L A N D Description Part Number Replacement Parts LED Light, 6W Z0B0047 Aluminum Mesh Filter 50200071 Optional Accessories Recirculating Kit BRC-0107 Replacement Charcoal Filter (each) Z0F-C091 Duct Cover Extension B1C-00ML To order parts, visit us online at https://store.zephyronline.com.
  • Page 27: Limited Warranty

    Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
  • Page 28: Product Registration

    Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 BML-C Use, Care, and Installation Guide...

This manual is also suitable for:

Bml-e30cgBml-e36cgBrisas blm islandBrisas bml-e30cgBrisas bml-e36cg

Table of Contents