SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Specifications ............... Preparing Electrical ............ Preparing Electrical and Ducting ......Converting to Air Recirculating Mode 11-12 ....Mounting the Range Hood ......13 FEATURES &...
Page 4
www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
Page 5
WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. For indoor use only. Do not use over cooking equipment greater than 60,000 BTU/hr. This hood is not intended to be used as a shelf. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
Page 6
BREEZE II - AK1200Bx, AK1236Bx PARTS SUPPLIED 1 - Hood 2 - Aluminum mesh filters 2 - Halogen light bulbs, GU-10 35W, Breeze I Only 1 - LED Light Strip, 5W, Breeze II Only 1 - 3-1/4” x 10” rectangular starting collar with damper (located inside hood body) 1 - Hardware package HARDWARE PACKAGE CONTENTS M4 x 2” (4) M4 x 1-1/2” (4) M4 x 1”...
Page 7
Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal T otal length x used 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
Page 8
www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 24”. Maximum mount height should be no higher than 32”. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its performance and efficiency.
Page 9
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape. Some Ducting Options Roof Pitch w/ Flashing & Cap Rear Ducting 3-1/4”x10” 3-1/4”x10” vertical ducting horizontal ducting Air Recirculating...
Page 11
ELECTRICAL WARNING All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground.
Page 12
www.zephyronline.com 2. Remove cover from junction box by 1. Remove filters (2) screws to gain access to electrical wiring. 3. If using a cable lock, pry open the 4. If using hood in air recirculating desired electrical knockout either on mode skip steps 4 and 5.
Page 13
The following instructions are for Breeze II and Breeze I hoods beginning with serial number prefix 13 and later. NOTE: Skip the recirculating preparation pages if you are ducting the air out of your home. 1. Secure each of the (2) spring clips to the An air recirculating kit (optional) must be safety grille body (A). Do this by inserting purchased before using hood in recirculat- the screw through the spring and into the ing mode.
Page 14
www.zephyronline.com NOTE: Skip this page if you are ducting the air out of your home. 5. Remove each of the 5 screws holding 6. Remove (2) interior recirculating panels. the (2) interior recirculating panels. 7. Place louvered recirculating plate over top opening and secure using the screws previously removed.
Page 15
electrical Hood is designed for installation under a kitchen cabinet (Fig 1) Duct 1. Select preferred duct location (vertical or horizontal) if opening cutout ducting out of kitchen. Refer to page 7 for details. 2. Begin installation by removing the filters (if installed) and side spacer panels (36” models only). (Fig 2) duct/silver 3. Reinforce cabinet with 1”x2” wood strips if additional tape strengthening is required or if cabinets are framed. 4. Temporarily position the range hood in the desired mounting location. Measure and mark the mounting holes, duct and electrical locations with a pencil.
Page 16
Lights Off/Dim/Bright is o , is dim, II is bright. Breeze II, AK12xxBx This button turns the motors on and o . It also shuts o power to the whole hood. If the lights are on and this button is pushed, they will also turn o .
Page 17
SURFACE MAINTENANCE: Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
Page 18
Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. If bulbs are difficult to turn due to prolonged use, firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber/latex glove and turn counter clockwise. Replacement bulbs are available at most hardware stores or from www.zephyronline.com Purchase type MR16 (GU-10) 35W halogen. BREEZE II, AK12xxBx LED LIGHT STRIPS In the unlikely event that your LED strip fails, please contact Zephyr to order replacement parts. See list of parts and accessories page for part #’s and contact information. To replace LED light strip 1. Remove aluminum mesh filters.
Page 19
TROUBLESHOOTING PROCEDURES FOR BREEZE I AND BREEZE II Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2. Check the power connection with the unit is is not connecting properly.
Page 21
DESCRIPTION PART # Replacement Parts Halogen Light Bulb, MR16 GU10, 35W (each) (AK11xx Only) Z0B0023 LED Light Strip, 5W (each) (AK12xxBx Only) Z0B0043 Metal Filter, 24” hoods (each) 50200013 Metal Filter, 30” and 36” hoods (each) 50200012 Optional Accessories Recirculating Kit 0AK11-21001 Replacement Charcoal Filters (2pk) 0AK11-20001 LED Light Bulb, GU10, 6W (each) (AK11xx Only) Z0B0040 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
Page 22
Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to manufacturing defects subject to the exclusions and limitations below.
Page 23
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.
Page 26
MISE EN GARDE DE SÉCURITÉ ......LISTE DU MATÉRIEL ............INSTALLATION Feuille de calcul pour le conduit ......Espace libre et hauteur de montage ....Options d’installation pour le conduit ....Spécifications ............... Préparation de l’électricité ......9 Préparation de l’électricité et du conduit ..10 Conversion en mode de reprise d’air .....
Page 27
www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
Page 28
ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
Page 29
2 – Filtres de maille métalliques 2 – Ampoules halogènes (GU10 35W) (Breeze I seulement) 1 - Bande lumineuse a LED, 5W (Breeze II seulement) 1 – Collier de fixation principal rectangulaire de 3¼” x 10” avec registre 1 – Trousse de quincaillerie CONTENU DE LA TROUSSE DE QUINCAILLERIE M4 x 2”...
Page 30
Longueur x Longueur x Pièces de conduit Pièces de conduit T otal T otal Nombre utilisé Nombre utilisé 3- 1/ 4” x 10” 1 pi 5 pi 6” circ. à rect., droit rect. de 3-1/4" x 10" 6”, 7”, 8”, 10” 1 pi 6”...
Page 31
www.zephyronline.com La hauteur de montage minimale entre la hotte et la cuisinière ne devrait pas être moins de 24”. La hauteur de montage maximale ne devrait pas excéder 32”. Il est important d’installer la hotte à la hauteur de montage adéquate. Si elle est trop basse, elle pourrait être endommagée par la chaleur en plus de présenter des risques d’incendie plus élevés alors que si elle est trop haute, elle sera difficile à...
Page 32
AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée.
Page 34
ÉLECTRICITÉ AVERTISSEMENT Tous les travaux électriques doivent être réalisés par un électricien qualifié ou par une personne possédant l’expérience technique et le savoir-faire nécessaire. Pour votre sécurité, enlevez le fusible ou ouvrez le disjoncteur de circuit avant de commencer l’installation. N’utilisez pas de cordon prolongateur ou de fiche d’adaptation avec cet appareil.
Page 35
www.zephyronline.com 2. Retirez le couvercle de la boîte de 1. Retirez les filtres. jonction pour avoir accès au câblage électrique. 3. Si vous utilisez un raccord de câble, 4. Si vous utilisez la hotte en mode de ouvrez soit l’une entrées reprise d’air, sautez les étapes 4 et 5.
Page 36
Les instructions qui suivent servent pour les hottes Breeze dont le numéro de série commence par 13 ou par un nombre plus élevé. NOTE : Sautez les pages de conversion en mode de reprise d'air si vous évacuez l'air à l'extérieur de votre maison. 1.
Page 37
www.zephyronline.com NOTE : Sautez cette page si l’air évacué par la hotte est dirigé à l’extérieur de votre maison. 5. Enlevez les cinq vis qui retiennent les 6. Enlevez les deux panneaux de reprise deux panneaux de reprise d’air intérieurs. d’air intérieurs.
Page 38
Pour installer la hotte sous une armoire de cuisine (fig 1.) fil électrique 1. Choisissez le type d’installation pour le conduit (vertical ou horizontal) découpage 2. Commencez l’installation en enlevant les filtres (s’ils sont de l’ouverture déjà en place) et les panneaux lateraux d’ecartement pour le conduit (36”...
Page 39
À 0 l’appareil est éteint; I équivaut à la vitesse lente, II à la vitesse moyenne et III à la vitesse maximale. Lumières - Allumer / Éteindre / Veilleuse 0 est éteint, I est faible et II est lumineux Breeze II, AK12xxBx Marche/Arrêt Ce bouton permet de mettre l’appareil en marche et de l’éteindre.
Page 40
ENTRETIEN DES SURFACES : N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de produits de nettoyage pour le four. N’utilisez aucun produit contenant de l’eau de Javel ou un produit contenant du chlorure. N’utilisez pas de laine d’acier ou des plaques abrasives qui risqueraient d’égrativer et d’endommager la surface.
Page 41
BREEZE II, AK12xxBx Bandes de lumière LED Dans l’éventualité peu probable d’une défaillance de votre bande LED, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la liste des pièces et accessoires à la page pour les références et les coordonnées.
Page 42
DÉPANNAGE POUR LES HOTTES BREEZE I ET BREEZE II Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que le disjoncteur et que l’installation, l’alimentation de l’appareil sont allumés. l’appareil ne 2. La ligne électrique et le raccord de câble ne sont 2.
Page 44
DESCRIPTION Nº DE PIÈCE Pièces de rechange : Ampoule GU10 35W (chaque) (Breeze I) Z0B0023 Filtre en métal, hotte de 24” (chaque) 50200013 Filtre en métal, hotte de 30” et 36” (chaque) 50200012 Accessoires facultatifs : Ensemble de reprise d’air 0AK11-21001 Filtre à...
Page 45
Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...
Page 46
ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente.