Advertisement

Quick Links

MD
Guangdong Transtek Medical Electronics Co., Ltd.
Zone A, No.105 ,Dongli Road, Torch Development District,
528437 Zhongshan, Guangdong,China
MDSS GmbH
EC
REP
Schiffgraben 41, 30175 Hannover, Germany
Importer: Aspedan Ltd, Unit 4 Capenhurst Technology Park, Capenhurst, Chester, CH16ES, United Kingdom
User Manual
Aspedan's Blood Pressure
M
Model: TMB-2284-B
Thank you for using Aspedan's Bluetooth Blood Pressure Monitor TMB-
2284-B.
Please read the user manual carefully and thoroughly to ensure the
safe usage of this product. Keep the manual for further reference in
case you have any problems.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the aspedan TMB-2284-B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TRANSTEK aspedan TMB-2284-B

  • Page 1 Thank you for using Aspedan's Bluetooth Blood Pressure Monitor TMB- 2284-B. Please read the user manual carefully and thoroughly to ensure the Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105 ,Dongli Road, Torch Development District, safe usage of this product. Keep the manual for further reference in 528437 Zhongshan, Guangdong,China case you have any problems.
  • Page 2: Table Of Contents

    CONTENTS Table of Contents INTRODUCTION........................... 2 General Description Indications for Use Measurement Principle Receiving and Inspecting your Monitor Safety Information LCD Display Monitoring Device Component Elements BEFORE YOU START ........................ 8 Choice of Power Supply Installing and Replacing the Batteries Setting the Date and Time Setting a user ID Pair a smart device with your Aspedan monitor...
  • Page 3: Introduction

    INTRODUCTION INTRODUCTION Safety Information General Description The signs below are in the user manual, labelling and other components of the blood pressure monitor and its accessories. Thank you for selecting Aspedan’s arm-type blood pressure monitor. This monitor features blood pressure measurement and pulse rate measurement, and then stores the result.
  • Page 4 INTRODUCTION INTRODUCTION Before Use Warning • This device is intended for indoor, home use, and is not intended for self-use in public areas. • This device is portable, but it is not intended for use during patient transport. • Do not apply the cuff on an arm that has an intravenous drip, or a blood transfusion attached. Do not kink, fold, stretch, compress, or otherwise deform the tube during measuring, as the cuff •...
  • Page 5: Lcd Display

    INTRODUCTION INTRODUCTION Monitoring Device LCD display CUFF AIR HOSE AIR CONNECTOR PLUG SYMBOL DESCRIPTION EXPLANATION Systolic blood pressure High pressure result USER BUTTON Diastolic blood pressure Low pressure result LCD DISPLAY Pulse display Pulse in beats per minute Type-C PORT PULSE/min START/STOP BUTTON mmHg...
  • Page 6: Before You Start

    BEFORE YOU START BEFORE YOU START Setting the Date and Time Choice of Power Supply It is important to set the clock before using your blood pressure Battery powered mode: monitor, so that a time stamp can be assigned to each record that 6VDC 4×AAA batteries (optional) is stored in the memory.
  • Page 7: Setting A User Id

    BEFORE YOU START BEFORE YOU START Setting a user ID 2. Press the “START/STOP” button to confirm the date format, then the month will flash. Repeat the same steps to set the month, day, time format, hour There are 3 user IDs available.
  • Page 8 BEFORE YOU START BEFORE YOU START Pair your monitor with the Aspedan App Specifications for Bluetooth Transmission You are the intended operator of this blood pressure monitor. You can Throughput 2.5K-5K measure your blood pressure and then save and send measurement data to Latency 50ms the Aspedan app (available on Apple iOS and Google/Android stores) using...
  • Page 9: Measurement

    MEASUREMENT MEASUREMENT How to apply the arm cuff to measure your blood Start the Measurement pressure You can use your monitor without pairing to the Aspedan App. To pair your monitor with the Aspedan App, please refer to the previous pages in this Only use a cuff that has been approved by the manufacturer for this device model.
  • Page 10 MEASUREMENT MEASUREMENT Note 4. Information regarding irregular pulse rates and excessive body To stop the measurement at any time, press the “START/STOP” • motion during blood pressure measurements. button. If you don’t pair with the Aspedan app, or don’t keep the app ON •...
  • Page 11: Data Management

    DATA MANAGEMENT DATA MANAGEMENT Delete Measurement Records Recall Measurement Records Delete your recorded measurements by following the steps detailed below. 1. When the monitor is off, press the “MEM” button. The user ID symbol will blink. A: Delete one record (example shown below for User 1). 2.
  • Page 12 DATA MANAGEMENT DATA MANAGEMENT B: Delete all records (example shown below for User 1). 4. Once deleted, your readings cannot be restored. The LCD will display Enter the memory recall mode as described in the previous “--”, as shown in the diagram below. section "Recall Measurement Records Press and hold the “USER”...
  • Page 13: Information For Users

    INFORMATION FOR USERS INFORMATION FOR USERS Tips for Measurement Maintenance Measurements may be inaccurate if taken in the following circumstances: In order to optimise the performance of your blood pressure monitor, please follow the instructions below. 1. Cleaning Process Step 1: Ensure to switch off and unplug the device prior to cleaning. Step 2: Use a soft cloth, dampened with soapy water, to clean the cuff first.
  • Page 14: About Blood Pressure

    ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE Why does my blood pressure What is systolic pressure and diastolic fluctuate throughout the pressure? day? Systolic Diastolic When ventricles contract and pump blood out of the heart, blood pressure reaches its maximum value in 1.
  • Page 15: Troubleshooting

    TROUBLESHOOTING SPECIFICATIONS If any abnormality arises during use, please check the following points: PROBLEM SYMPTOM CHECK THIS REMEDY Batteries are depleted. Replace with new batteries. Display does No power Batteries are inserted Insert the batteries not light up. incorrectly. correctly. Adaptor is inserted Insert the AC adaptor incorrectly.
  • Page 16: Authorised Component

    Authorised Component Hereby we Please use the authorised adaptor. Guangdong TRANSTEK Medical Electronics Co., Ltd. Address: Zone A, No.105 Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China declare that this DoC is issued under our sole responsibility for the...
  • Page 17: Emc Guidance

    EMC GUIDANCE EMC GUIDANCE EMC Guidance Technical Description: 1. All necessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the expected lifetime. The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments. 2.
  • Page 18 EMC GUIDANCE EMC GUIDANCE Table 2 Table 3 Guidance and manufacturer’s declaration – electromagnetic Immunity IEC 60601-1-2 Immunity Test Compliance level Test level Electrostatic ±8 kV contact ±8 kV contact ±2 kV, ±4 kV, ±8 kV, ±15 kV air ±2 kV, ±4 kV, ±8 kV, ±15 kV air IEC 61000-4-2 ±2 kV for power supply lines ±2 kV for power supply lines...

Table of Contents