Appendix; Connecting To Dc Power; Preparing For Installation; Grounding The Switch - Cisco WS-C3560-48PS-S Hardware Installation Manual

Catalyst 3560 series switch
Hide thumbs Also See for WS-C3560-48PS-S:
Table of Contents

Advertisement

Connecting to DC Power

This appendix describes how to make DC power connections to the Catalyst 3560V2-24TS-SD switch.
See
Switches)"
Connecting to DC Power
To connect the Catalyst 3560V2-24TS-SD switch to a DC-input power source, follow the steps in these
sections:
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Note
We recommend that you use 18 AWG copper wiring for Network Equipment Building Systems (NEBS)
installation. This guideline follows the standard guidelines for DC power wiring in the Central Office.
When an RPS is connected to the Catalyst 3560V2-24TS-SD switch, the switch is not NEBS compliant.
Note
Note
The grounding architecture of this product is DC-isolated (DC-I).
To comply with the intrabuilding lightning surge requirements, intrabuilding wiring must be shielded,
Caution
and the shield for the wiring must be grounded at both ends.
OL-6337-07
"Switch Installation (24- and 48-Port Switches)"
for instructions on installing the switch.
Preparing for Installation, page C-2
Grounding the Switch, page C-2
Wiring the DC-Input Power Source, page C-5
A P P E N D I X
and
"Switch Installation (8- and 12-Port
Catalyst 3560 Switch Hardware Installation Guide
C
C-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents