Installing The Dc-Input Power Supply; Removing And Installing The Dc-Input Power Supply - Cisco ME-C6524GS-8S Installation Manual

Me 6500 series
Table of Contents

Advertisement

Removing and Installing the DC-Input Power Supply

Installing the DC-Input Power Supply

Before performing any of the following procedures, ensure that power is removed from the DC
Warning
circuits. To ensure that all power is removed, locate the circuit breakers or fuses on the DC power
lines that service the DC circuits. Turn OFF the DC power line circuit breakers and remove the DC
power line fuses. Statement 322
When installing or replacing the unit, the ground connection must always be made first and
Warning
disconnected last. Statement 1046
To install a DC-input power supply, follow these steps:
Step 1
Ensure that the system (earth) ground chassis connection has been made.
Step 2
Verify that power is off to the DC circuit that feeds the power supply that you are installing.
As an added precaution, place the appropriate safety flag and lockout devices at the source power circuit
breaker, or place a piece of adhesive tape over the circuit breaker handle to prevent accidental power
restoration while you are working on the circuit.
Remove the new DC-input power supply from its protective packaging.
Step 3
Step 4
Verify that the power switch is in the off (0) position on the power supply that you are installing.
Grasp the power supply handle with one hand, and place your other hand underneath the power supply.
Step 5
Slide the power supply into the power supply bay. Make sure that the power supply is fully seated in the
bay. (See
Note
Tighten the two power supply captive installation screws.
Step 6
Remove the plastic cover from the terminal block.
Step 7
Attach the appropriate lugs to the source DC wires. The maximum width of a lug is 0.300 inch (7.6 mm).
Step 8
Either insulated crimp-on spade lugs or insulated crimp-on ring connectors can be used on the source
DC cables. They should be sized according to local and national installation requirements and electrical
codes.
Note
Cisco ME 6500 Series Ethernet Switch Installation Guide
4-4
Figure
4-2.)
The DC power supply is equipped with an EMI gasket on the top, bottom, and sides (on the front
edge) of the power supply. When sliding the power supply into the power supply bay, be careful
not to damage the EMI gaskets.
The wire should be sized according to local and national installation requirements and electrical
codes. Use only copper wire.