Environmental Monitoring Temperature Sensor - Cisco MWR 1941-DC - 1941 Mobile Wireless Router Hardware Installation Manual

Mobile wireless edge router
Hide thumbs Also See for MWR 1941-DC - 1941 Mobile Wireless Router:
Table of Contents

Advertisement

Chapter 1
Overview of the Cisco MWR 1941-DC Router

Environmental Monitoring Temperature Sensor

The MWR 1941-DC router has a temperature sensor to detect over-temperature conditions inside the
chassis. The over-temperature detection trips at 75°C +/- 5%. This condition is reported to the processor
as an interrupt and software then takes action on this interrupt to generate the appropriate alarming. If
the router reaches a temperature of 90°C, the power supply will cycle to prevent the box from exceeding
that temperature in a powered up state.
System Specifications
Table 1-4
Table 1-4
Description
Dimensions (H x W x D)
Weight
Console and Auxiliary ports
Operating Temperature
Non-Operational Temperature
Operating Humidity
Operating Altitude
Operating Vibration
Non-Operational Vibration
Operating Acoustics
1. When two or less VWIC-2MFT-T1/E1-DIRs are installed in the Cisco MWR 1941-DC router, an operating temperature
Cisco MWR 1941-DC Router Interface Numbering
Each network interface on a Cisco MWR 1941-DC router is identified by a slot number and a port
number.
Figure 1-5
following configuration for a Cell Site DCN implementation:
78-15827-06B0
lists the Cisco MWR 1941-DC router system specifications.
Cisco MWR 1941-DC Router System Specifications
range of 14 to 131°F (-10 to +55°C) is supported
shows an example of interface numbering on a Cisco MWR 1941-DC router with the
A VWIC in two of the three VWIC slots
A 4-port asynchronous/synchronous serial network module in slot 1
Two built-in Fast Ethernet interfaces
Cisco MWR 1941-DC Mobile Wireless Edge Router Hardware Installation Guide
Specification
1.72 x 17.5 x 12.5 in. (4.368 x 44.45 x 31.75 cm) 1RU/19.00 Rack
Mount
10.5 lb (4.77 kg)
RJ-45 connector
1
32 to 122°F (0 to + 50°C)
-40 to 185°F (-40 to 85°C)
5 to 90% RH (non-condensing)
+3000m @ 113°F (45°C)
0.41 Grms, 3 to 500 Hz/2 hours per axis
GR-63-CORE earthquake resistance, Zone 4, shelf-level
1.12 Grms, 3 to 500 Hz/30 minutes per axis
< 60 dBa
.
Environmental Monitoring Temperature Sensor