Chapter 3
Installing the Router
Remove the ground-lug screw from the rear panel of the router (shown in
Step 1
a standard Phillips screwdriver or a ratcheting torque screwdriver with a Phillips head.
Set the screw aside.
Step 2
If your ground wire is insulated, use a wire-stripping tool to strip the 10-AWG ground wire to 0.5 inch
Step 3
± 0.02 inch (as shown below).
Slide the open end of your ground lug over the exposed area of the 10-AWG wire.
Step 4
Using a crimping tool (as specified by the ground lug manufacturer), crimp the ground lug to the 10-AWG
Step 5
wire (as shown below).
Use the screw to attach the ground lug and wire assembly to the rear panel of the switch.
Step 6
Step 7
Using a ratcheting torque screwdriver, torque the ground-lug screw to 15 1bf-in (or 240 ounce-force
inches [240 ozf-in]).
78-15827-06B0
Connecting the MWR 1941-DC Router to a DC-Input Power Supply
0.50" ± 0.02"
Wire lead
Insulation
Cisco MWR 1941-DC Mobile Wireless Edge Router Hardware Installation Guide
Figure 1-4 on page
1-4). Use
3-11