ACS300 at client sites. The guide is also intended for IT personnel, who should use it in conjunction with Brivo online help. It may be used by dealers and their sales professionals to help them conduct pre-sales, and to provide client support during the installation process.
A current list of compatible readers and keypads is maintained on Brivo’s website at http://www.brivo.com. If you have a specific model of reader or keypad that is not listed on the Brivo website, please contact Technical Support at 1-866-BRIVO-4-U to determine compatibility.
NOTE: Firmware Upgrade at First Time Connect When first registered and connected to Brivo Access, your ACS300 will automatically download and install the latest firmware. This process may take several minutes, so do not disconnect or cut power to your ACS300 during this process.
OSDP readers. For instructions on connecting to the local administrative interface and configuring the OSDP reader(s), please refer to the Panel Networking Guide (available at www.brivo.com). Verify connection of the LAN to the ACS300 (this should already have been done when...
Page 17
ACS300 can support up to two wired locks, and up to 30 wireless locks, with a total of 30 in any combination. NOTE: Wiegand readers use a 5V signaling level and Brivo hardware is compliant with 5V Wiegand readers. Any reader that claims to be Wiegand but does not use 5V signaling is not compatible with Brivo hardware.
Page 19
5. If used, wire the AUX INPUTS terminal block. The AUX INPUT 1 and AUX INPUT 2 terminals are contact closure type inputs. The terminals can be used for a variety of purposes, and are programmed through the Brivo programming interface.
Mounting Firmware Upgrade Mount the box directly to drywall using the four outer corner screw When first registered and connected to the Brivo mounting holes (red below) (or two alternate positions) (blue below) Access, your ACS300 will automatically download and on the back of the ACS300 enclosure.
Click on the Setup dropdown menu, choose the Site/Doors tab, then click on the Control Panels link. If the panel has already been added to the Brivo Access account, the Last Contact field should be populated with today’s date and a recent timestamp. This indicates successful configuration of the ACS300.
Page 27
3/28/2017 Added UL requested language and updates 3/29/2017 Changed 1.6A to 2.5A on Page 13 Removed reference to ACS300-F and Brivo Onair for Government and 4/26/2017 removed reference to ACS300-S and Brivo Onsite 6/7/2017 Added FCC 15B Class A and EN 55032 Class A language...