Brivo ACS300 Series Installation Manual
Hide thumbs Also See for ACS300 Series:

Advertisement

Quick Links

Brivo ACS300 Series
Installation Guide
Models: B-ACS300-E, B-ACS300-E-B, B-ACS300V2-E, B-ACS300V2-E-B
2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACS300 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Brivo ACS300 Series

  • Page 1 Brivo ACS300 Series Installation Guide Models: B-ACS300-E, B-ACS300-E-B, B-ACS300V2-E, B-ACS300V2-E-B 2024...
  • Page 2 Equipment compliant with the Class A requirements of this publication should have a warning notice in the user guide stating that it could cause radio interference. For example: Warning Operation of this equipment in a residential environment could cause radio interference. © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 3 © 2024 Brivo Systems LLC. All rights reserved. Brivo® is a trademark of Brivo Systems LLC. Brivo Systems LLC., 7700 Old Georgetown Road, Suite 300, Bethesda, MD 20814 © 2024 Brivo Systems LLC. All rights reserved.
  • Page 4: Table Of Contents

    Table of Contents Table of Contents Introduction Pre-Installation Procedures General Assembly Procedures Powering and Testing Procedures Installation Procedur es Quick Reference Sheet © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 5: Introduction

    ACS300 at client sites. The guide is also intended for IT personnel, who should use it in conjunction with Brivo online help. It may be used by dealers and their sales professionals to help them conduct pre-sales, and to provide client support during the installation process.
  • Page 6: Wire Recommendations

    Additional Resources The following additional resources are available for the installer as well as the client. Panel Networking Guide Brivo Cellular Network Router Configuration Guide Technical Support: 1-866-BRIVO-4-U resources.brivo.com © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 7: Pre-Installation Procedures

    A current list of compatible readers and keypads is maintained on Brivo’s website at http://www.brivo.com. If you have a specific model of reader or keypad that is not listed on the Brivo website, please contact Technical Support at 1-866-BRIVO-4-U to determine compatibility.
  • Page 8: Follow Safety Precautions

    UPS (Uninterruptible Power Supply) between the AC Mains and the transformer. © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 9: General Assembly Procedures

    ACS300 securely in place. Recommended Screw Size: Use #8 X 1" panhead screws. If mounting to drywall only, also use a #8 plastic drywall screw anchor. ACS300 Mounting Option One © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 10 #8 drywall screw anchor. For junction box mounting, the recommended screw Mounting Plate size is #6-32 by 6 inch screw. ACS300 Mounting Option 4 © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 11 DISABLE Wi-Fi. The ACS300 Tamper On/Off Toggle in the off position deactivates both optical and physical tamper switches. Optical Tamper Reflector Physical Tamper Tamper Switch and Optical Tamper Sensor Locations © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 12 ACS300. NOTE: If the tamper switch is not going to be used, leave the supplied jumper on this connector to keep the circuit closed. © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 13 Voltage (VDC) Current (A) 12VDC 2.5 A All Brivo ACS300-E models Input PoE+ [42.5 – 57VDC] 0.65A 12VDC 2.5 A All Brivo ACS300v2-E models Input PoE+ [42.5 – 57VDC] 0.65A © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 14: Powering And Testing Procedures

    NOTE: Firmware Upgrade at First Time Connect When first registered and connected to Brivo Access, your ACS300 will automatically download and install the latest firmware. This process may take several minutes, so do not disconnect or cut power to your ACS300 during this process.
  • Page 15 LEDs will display each issue for two seconds. The last issue displayed on the LEDs will display for an additional five seconds before the cycle starts again. © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 16: Installation Procedures

    OSDP readers. For instructions on connecting to the local administrative interface and configuring the OSDP reader(s), please refer to the Panel Networking Guide (available at www.brivo.com). Verify connection of the LAN to the ACS300 (this should already have been done when...
  • Page 17 ACS300 can support up to two wired locks, and up to 30 wireless locks, with a total of 30 in any combination. NOTE: Wiegand readers use a 5V signaling level and Brivo hardware is compliant with 5V Wiegand readers. Any reader that claims to be Wiegand but does not use 5V signaling is not compatible with Brivo hardware.
  • Page 18 When the switch is closed, the control panel interprets this input as a “Door Closed” condition. This circuit provides door status information (open/closed) to the control panel so ACS Online can take appropriate action locally, or send email notifications if necessary. © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 19 5. If used, wire the AUX INPUTS terminal block. The AUX INPUT 1 and AUX INPUT 2 terminals are contact closure type inputs. The terminals can be used for a variety of purposes, and are programmed through the Brivo programming interface.
  • Page 20 NOTE: The ACS300 board’s factory default setting is Half-Duplex communication when using RS-485 reader functionality. In order to switch to Full-Duplex communication, move the HDX/FDX switch to the Full-Duplex position. © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 21 Switch (Door 1 or Door 2). RS-485 Termination Switch Location Door 1 Wet/Dry Select Switch (SW-8) Door 2 Wet/Dry Select Switch (SW-9) ACS300 Wet/Dry Door Contact Switches for Doors 1 and 2 © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 22 The wire to the GND terminal. This is the standard Ground circuit for the reader. The wire to the 12VDC terminal. This provides +12VDC to power the reader. DATA0/RXD+ DATA1/RXD- TXD+ TXD- 12 VDC Wire Doors for OSDP Readers using RS-485 © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 23 3. Attach the silver connector cap to the right connector of the Wi-Fi chip. 4. When the connector attaches, you may hear an ACS300 Wi-Fi Antenna Connection audible click as it fits into place. © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 24 2. The ground contact point is the copper ringed screw point located in the lower left corner of the ACS300 board. Earth Ground ACS300 Earth Ground © 2024 Brivo Systems LLC. All rights reserved. PUB-ACS300 Installation Guide_v1.24...
  • Page 25: Quick Reference Sheet

    Mounting Firmware Upgrade Mount the box directly to drywall using the four outer corner screw When first registered and connected to the Brivo mounting holes (red below) (or two alternate positions) (blue below) Access, your ACS300 will automatically download and on the back of the ACS300 enclosure.
  • Page 26: Troubleshooting

    Click on the Setup dropdown menu, choose the Site/Doors tab, then click on the Control Panels link. If the panel has already been added to the Brivo Access account, the Last Contact field should be populated with today’s date and a recent timestamp. This indicates successful configuration of the ACS300.
  • Page 27 3/28/2017 Added UL requested language and updates 3/29/2017 Changed 1.6A to 2.5A on Page 13 Removed reference to ACS300-F and Brivo Onair for Government and 4/26/2017 removed reference to ACS300-S and Brivo Onsite 6/7/2017 Added FCC 15B Class A and EN 55032 Class A language...