THIS MANUAL CONTAINS THE FOLLOWING SECTIONS WHICH ARE TO BE CONSIDERED AN INTEGRAL PART
G3E0GB-3
General
T3E0GB-3
Troubleshooting
This manual has been designed to enable the unit to be
installed, started up and maintained correctly, making it
essential to observe the following points:
- these instructions should be read carefully;
- the unit must be installed, tested and maintained by expert
personal who meet the relevant legal requirements (Italian
law No. 46 of 5/3/1990).
- The manufacturer declines all liability for any electrical
and/or mechanical changes to the unit, which also invalid its
guarantee. Any operations whatsoever that have not been
expressly authorised and do not respect the information in
this manual shall invalidate the guarantee.
- Observe the local safety regulations in force when installing
the unit.
- Make sure the power supply conforms to the data on the
unit's rating plate, located inside the door of the main
electrical panel.
The manufacturer declines all liability for any damage that may be caused whether directly or indirectly to persons or things
This unit has been especially designed and manufactured so
to prevent any risk to persons and health hazard.
For this reason, design solutions fit to eliminate (where
possible) any cause of risk and sensibly reduce the
probability of danger have been adopted.
:6+
:6++
*(1(5$/
OF THE WHOLE AND ARE THEREFORE NOT TO BE DETACHED.
R3E0GB-3
Reception/Positioning
Electrical connections
M3E0GB-3
Maintenance
Water connections
*(1(5$/ :$51,1*6
if these instructions are not heeded.
$'',7,21$/ 6$)(7< 35(&$87,216
C.Art. M03E40M6



,167$//$7,21
23(5$7,21 $1'
0$,17(1$1&( 0$18$/
E3E0GB-3
F3E0GB-3
Start-up
L3E0GB-3
K3E0GB-3
Additional precautions
- This manual and the unit's wiring diagram should be
carefully stored so that they are readily available to the
operator when required.
- The packaging material (plastic bags, polystyrene foam,
nails, etc.) is potentially dangerous and should therefore be
kept away from children and recycled in compliance with the
local regulations in force.
- The unit must only be used for the specific purpose it was
designed, as described in the paragraph GENERAL
TECHNICAL SPECIFICATIONS Any use other than that
specified does not imply any commitment or constraint by
the manufacturer in any way whatsoever.
- Switch off the unit in the event of faults or poor operation.
- Only have repairs carried out by a service centre
authorised by the manufacturer, and insist on the use of
original spare parts only.
Failure to comply with the above may compromise the safety
of the unit.
Please refer to the 5HVLGXDO 5LVNV VHFWLRQ of this manual
and strictly observe the behaviour prescriptions listed there
in order to prevent any possible risk that hasn't been
possible to avoid in the design stage.
5&
C3E0GB-3
Controls
*(*%

Advertisement

loading
Need help?

Need help?

Do you have a question about the WSH-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for CLIVET WSH-2

  • Page 1 Библиотека СОК  :6+ :$7(5&22/(' :$7(5 &+,//(56  :,7+ 6&5(: &2035(66256  :6++ :$7(5:$7(5  +($7 38036 :,7+ 6&5(: &2035(66256 5& ,167$//$7,21 23(5$7,21 $1' 0$,17(1$1&( 0$18$/ *(1(5$/ THIS MANUAL CONTAINS THE FOLLOWING SECTIONS WHICH ARE TO BE CONSIDERED AN INTEGRAL PART OF THE WHOLE AND ARE THEREFORE NOT TO BE DETACHED.
  • Page 2 *(1(5$/ 63(&,),&$7,216 6L]HV              Cooling capacity 1042 1181 1281 1381 1504 1565 Compr. Input power Heating capacity 1021 1138 1245 1387 1518 1645 1806 1916 Compr. Input power Compressor type monoscrew N°...
  • Page 3 1RW UHTXLUHG  CE = PED (European testing) standard :DWHU ORZ WHPSHUDWXUH % C = CLIVET (Internal testing) range of application of this version is between +5 C down to -8 C using glycol solution. Available version: - Brine chiller...
  • Page 4 6(77,1* 7+( &87287 '(9,&(6 $1' &21752/6 67$1'$5' Opens Closes High pressure switch (kPa) 2700 1940 High pressure safety valve (kPa) 3000 Low pressure switch (kPa) Low pressure safety valve (kPa) 1900 Antifreeze protection ( C) Max. compressor starts per hour (n ) Safety discharge thermostat ( C)
  • Page 5 ',0(16,216 6L]H  1928 1164 2250 1000 3922 1132 "G" 3000 6L]H  1985 1995 1937 1927 1RWH Dimensions are in mm. .H\ (1) COMPRESSOR (2) EVAPORATOR (3) CONDENSER (4) EVAPORATOR INLET WATER (5) EVAPORATOR OUTLET WATER (6) CONDENSER INLET WATER (7) CONDENSER OUTLET WATER (8) HOLE TO HANG UNIT (9) LIFTING HOLES...
  • Page 6 6L]HV  1928 1296 2200 1187 1000 4100 1133 "G" 3000 6L]H   1924 1935 1879 1892 1992 1980 2037 2024 1RWH Dimensions are in mm. .H\ (1) COMPRESSOR (2) EVAPORATOR (3) CONDENSER (4) EVAPORATOR INLET WATER (5) EVAPORATOR OUTLET WATER (6) CONDENSER WATER INLET (7) CONDENSER WATER OUTLET (8) HOLE TO HANG UNIT...
  • Page 7 6L]HV  2150 1349 2700 1187 4420 1000 1122 "G" 3200 6L]H   2380 2377 2388 2388 1850 2043 1839 2032 1RWH Dimensions are in mm. .H\ (1) COMPRESSOR (2) EVAPORATOR (3) CONDENSER (4) EVAPORATOR WATER INLET (5) EVAPORATOR WATER OUTLET (6) CONDENSER WATER INLET (7) CONDENSER WATER OUTELT (8) HOLE TO HANG UNIT...
  • Page 8 6L]H  2150 1399 2700 1187 1000 4460 1122 "G" 3500 6L]H  2069 2067 2288 2393 1RWH Dimensions are in mm. .H\ (1) COMPRESSOR (2) EVAPORATOR (3) CONDENSER (4) EVAPORATOR WATER INLET (5) EVAPORTAOR WATER OUTLET (6) CONDENSER WATER INLET (7) CONDENSER WATER OUTLET (8) HOLE TO HANG UNIT (9) LIFTING HOLES...
  • Page 9 6L]HV  2150 1510 2630 1252 1000 4468 1122 "G" 4000 6L]H   2217 2217 2479 2480 2148 2251 1886 1988 1RWH Dimensions are in mm. .H\ (1) COMPRESSOR (2) EVAPORATOR (3) CONDENSER (4) EVAPORATOR WATER INLET (5) EVAPORATOR WATER OUTLET (6) CONDENSER WATER INLET (7) CONDENSER WATER OUTLET (8) HOLES TO HANG UNIT...
  • Page 10 6L]H  2000 2218 1276 1615 2630 1242 4162 1815 1548 "G" 3500 6L]H  2167 2203 1995 1959 1009 1007 1RWH Dimensions are in mm. .H\ (1) COMPRESSOR (2) EVAPORATOR (3) CONDENSER (4) EVAPORATOR WATER INLET (5) EVAPORATOR WATER OUTLET (6) CONDENSER WATER INLET (7) CONDENSER WATER OUTLET (8) HOLES TO HANG UNIT...
  • Page 11 (17) ONLY ACOUSTIC CONFIGURATION EN - Z. I. 32030 VILLAPAIERA - FELTRE (BL) Italy - Tel (0439) 3131 - Fax (0439) 313300 - web http://www.clivet.com All technical specifications presented in this manual are not binding and subject to change without notice.