Electrical Specifications
1. All wiring must comply with local and national
electrical codes and be installed by a qualified
electrician. If you have any questions regarding
the following instructions, contact a qualified
electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installation and
operation of this unit.
3. This unit draws 9.0 amps (nameplate rated)
under Cooling Mode and 12.0 amps (nameplate
rated) under Heating Mode and may be used in
any properly wired, general purpose 15 amp
household grounded receptacle.
4. For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether the wall outlets in your home
are properly grounded, please consult a qualified
electrician. DO NOT USE PLUG ADAPTERS
OR EXTENSION CORDS WITH THIS UNIT.
If it is necessary to use an extension cord with
this unit, use an approved "air conditioner"
extension cord only. (available at most local
hardware stores)
Unit Specifications:
Cooling Capacity
Heating Capacity (High/Low)
Dehumidifying Capacity
Noise Level
Power Source
Refrigerant
Internal Water Tank Capacity
External Water Tank Capacity
Unit Weight
Unit Dimensions (inches) W x D x H
Unit Dimensions (cm) W x D x H
Fan Speeds
Control Panel (Illuminated)
Remote Control
Time of Day Clock
Auto - Timer
Power Consumption:
Cooling
Heating
Dehumidifying
Fan
NOTE: Specifications are subject to change without notice, for further improvements.
5. The manufacturers nameplate is located on the
rear panel of the unit and contains electrical and
other technical data specific to this unit.
6. To avoid the possibility of personal injury, always
disconnect the power supply to the unit, before
installing and/or servicing.
Suggested Individual Branch Circuit
Nameplate Amps
7.4 to 12.0
AWG- American Wire Gage
* Based on copper wire at 60°C temperature rating.
Receptacle and Fuse Types
Rated Volts
Amps
Wall Outlet
Fuse Size
Time Delay Fuse
(or circuit breaker)
3
Table 1
AWG Wire Size*
14
Table 2
125
15
15
Plug Type
Model SPAC8499
8400 Btu/h
1380W/830W
57 Pints (27 L / 24 Hrs)
Less than 54 dB(A)
115 V / 60 Hz
R22
5.5 L (11.6 Pints)
8.5 L (18 Pints)
38 kg (83.7 lb.)
15
1
/
" x 18" x 32
5
/
4
8
38.7 x 45.6 x 82.9
3
Soft Touch Controls
Yes
Yes
Yes
1050 Watts (9.0 Amps)
1380 Watts (High) 12 Amps
830 Watts (Low) 7.2 Amps
1050 W (9.0 Amps)
90 W (0.8 Amps)
"

Hide quick links: