Digital Panel Meters 47NL Series
LOOP POWERED DIGITAL PANEL METER
(4 1/2 digit, LED display type, with terminal block)
Model: 47NLNT
OPERATING MANUAL
MG CO., LTD. www.mgco.jp
47NLNT EM-9564-B Rev.7
1
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 47NLNT and is the answer not in the manual?

Questions and answers

Summary of Contents for MG 47NLNT

  • Page 1 Digital Panel Meters 47NL Series LOOP POWERED DIGITAL PANEL METER (4 1/2 digit, LED display type, with terminal block) Model: 47NLNT OPERATING MANUAL MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 2: Table Of Contents

    3.4 STEP 4. DISPLAY SCALING SPAN ...................34 3.4.1 OPERATING PROCEDURE ...................34 3.5 STEP 5. DECIMAL POINT POSITION ................36 3.5.1 OPERATING PROCEDURE ...................36 4. OPERATION ..................38 5. PARAMETER CONFIGURATION ............39 MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 3 13. INSPECTION / CLEANING ..............69 14. TROUBLESHOOTING ................70 14.1 ERROR MESSAGES ......................70 14.2 INITIALIZING SETTING VALUES ..................70 14.2.1 OPERATING PROCEDURE .................70 14.3 CONFIRMING FIRMWARE VERSION ................72 14.3.1 OPERATING PROCEDURE .................72 MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 4 15.4 PARAMETER MAP ......................76 15.4.1 OPERATION IN MEASURING MODE ..............76 15.4.2 SCALING SETTING MODE ..................77 15.4.3 ADVANCED SETTING MODE ................78 15.4.4 LOCKOUT SETTING MODE ................79 15.5 CHARACTER SET ......................80 MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 5: Introduction

    Ordering Information Sheet NXXXXX (included with the option code ‘/SET’ only) ■ MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 6: Safety Precautions (That Must Be Observed)

    • Using the unit continuously may result in a fire or electric shock. Stop using the unit if it is dropped or damaged. • Using the unit continuously may result in a fire or electric shock. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 7 • Doing so may result in electric shock, damage of the unit or injury. Do not use the unit in the atmosphere where combustible gas is present. • Doing so may result in inflammation, ignition or smoke. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 8: Points Of Caution

    In case that it is removed, replace it according to the following pin No. Use a minus screwdriver with blade edge 0.4 mm (0.02”) and blade width 2 mm (0.08”) to connect the wires to the tension clamp terminal block on the body. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 9: Wire Color

    – The packing is run off the edge. – The packing is cut off. – There are foreign objects sticking. • When replacement of the watertight packing is needed, consult us. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 10: Component Identification

    • The engineering unit sticker label position is our recommended position. • When an engineering unit is specified by the Ordering Information Sheet, the unit(s) will be shipped with the sticker label put on the above position. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 11 • When a tag No. is specified, the unit(s) will be shipped with the tag No. sticker labels put on the top of the body and the front of the terminal block. Max. 17 alphanumeric characters can be specified. Please consult us. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 12 Contents of the specification label depend on the specifications. ■ TERMINAL BLOCK • Front view NOTE The tag No. label sticker position is our recommended position. • Rear view Connector MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 13: Installation

    TERMINAL BLOCK • FRONT VIEW 96.0 (3.78) 6.4 (.25) 2 – 4.5 (.18) dia. 9 10 • REAR VIEW • SIDE VIEW Max. 20.5 (.81) (.31) (.08) MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 14: Panel Cutout Dimensions

    (1) Mount the watertight packing to the body. Fit the concave part of the watertight packing in the convex part of the body. Body Watertight packing IMPORTANT The watertight packing must be placed. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 15 (3) Connect the harness of the body to the connector terminal block. Connector Harness Terminal block IMPORTANT • Insert the harness deeply. • Do not contort the harness wires. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 16 Unit xing screws (M4 x 20) IMPORTANT To conform to degree of protection IP66, confirm visually that the packing is not contorted, cut off or excessively run off the edge after installation. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 17 To remove the unit from the panel, perform the above procedure inversely. Do not pull the wires to remove the harness. Grip the housing to remove in order to prevent disconnection of the wires. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 18: Wiring Instructions

    • In using non-insulated solderless terminals, cover them with insulating caps or tubes. • Ring tongue terminals are recommended rather than spade tongue terminals to prevent from falling off. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 19: Terminal Assignment

    Input Current Ground (resistance ‒ 100 ohms or less) ■ CONNECTION EXAMPLE • 2-WIRE • 4-WIRE Power source 4 – 20 mA (current loop supply) Input device MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 20: Attaching/Removing Terminal Cover

    1.6.5 ATTACHING/REMOVING TERMINAL COVER Attach the terminal cover for safety after wiring. Terminal cover MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 21: Basic Setting And Operation

    Input scaling: 0% input value (input scaling ZERO) and 100% input value (input scaling SPAN) Display scaling: 0% display value (display scaling ZERO) and 100% display value (display scaling SPAN) MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 22: Basic Setting Procedure

    Return to Measuring Mode (measurement started). • Hold down ↓ or Scale/↑ button for 3 seconds or more to apply the new setting and return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 23: Basic Setting Operation And Instructions

    • Each time pressing Up button, the numeral is incremented by 1. • The negative sign (-) must be set to the leftmost digit. For example, set ‘-04.00’ instead of ‘-4.00’ . * Fifth digit MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 24 Press Up button to select a desired decimal point position. Press ↓ or Scale/↑ button to apply the new setting. • The next or previous parameter setting is indicated. *1 Display depands on the settings. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 25: Instructions On Basic Operation

    • If you get lost in a setting mode, you can execute initialization. (Refer to 14.2 INITIALIZING SETTING VALUES.) ■ ORDER TO DISPLAY PARAMETERS • Refer to 5. PARAMETER CONFIGURATION for details. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 26: Setting Scaling Values

    Display Display SPAN ZERO Display Scaling Display Scaling ZERO SPAN Input Input ZERO SPAN ZERO SPAN Input Scaling Input Scaling MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 27 Following pages describe operating procedures in each step to set the input scaling to 4 – 20 mA DC, and the display scal- ing to 0.0 – 1000.0 m³ as an example. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 28: Step 1. Input Scaling Zero

    Skip to Step 6 if the default value is acceptable. Press Shift button to shift the display into the setting standby mode. Blinking • The fifth digit starts blinking, to which you can apply changes. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 29 • Each time pressing Shift button, the blinking digit moves to the right. ■ SETTING A NUMERICAL VALUE * Fifth digit • Each time pressing Up button, the numeral is incremented by 1. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 30: Step 2. Display Scaling Zero

    Skip to Step 7 if the default value is acceptable. Press Shift button to shift the display into the setting standby mode. Blinking • The fifth digit starts blinking, to which you can apply changes. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 31 • Each time pressing Shift button, the blinking digit moves to the right. ■ SETTING A NUMERICAL VALUE * Fifth digit • Each time pressing Up button, the numeral is incremented by 1. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 32: Step 3. Input Scaling Span

    Skip to Step 7 if the default value is acceptable. Press Shift button to shift the display into the setting standby mode. Blinking • The fifth digit starts blinking, to which you can apply changes. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 33 • Each time pressing Shift button, the blinking digit moves to the right. ■ SETTING A NUMERICAL VALUE * Fifth digit • Each time pressing Up button, the numeral is incremented by 1. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 34: Step 4. Display Scaling Span

    Skip to Step 7 if the default value is acceptable. Press Shift button to shift the display into the setting standby mode. Blinking • The fifth digit starts blinking, to which you can apply changes. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 35 • Each time pressing Shift button, the blinking digit moves to the right. ■ SETTING A NUMERICAL VALUE * Fifth digit • Each time pressing Up button, the numeral is incremented by 1. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 36: Step 5. Decimal Point Position

    Skip to Step 7 if the default value is acceptable. Press Shift button to shift the display into the setting standby mode. Blinking • The indication starts blinking, to which you can apply changes. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 37 • “No decimal point” to “4 decimal places” can be selected in the decimal point position setting. SETTING VALUE FUNCTION SETTING VALUE FUNCTION No decimal point 3 decimal places (10 1 decimal place (10 4 decimal places (10 2 decimal places (10 MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 38: Operation

    Apply 20 mA input (100%) and make sure that 1000.0 m³ is indicated. NOTE When the indication is shifted with the function indicators off, perform Teach Calibration. (Refer to 12.1 TEACH CALIBRA- TION.) MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 39: Parameter Configuration

    5. PARAMETER CONFIGURATION ■ MODE Parameters can be grouped in several modes. The 47NLNT has modes as shown in the following table. MODE FUNCTION MEASUREMENT Measuring Normal measurement state where the unit takes in input. Present value, MAX and Measuring MIN values can be indicated in Measuring Mode.
  • Page 40 • The display depends on the settings and input. The above displays show default values. • Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode from each parameter. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 41 • The display depends on the settings and input. The above displays show default values. • Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode from each parameter. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 42 • The display depends on the settings and input. The above displays show default values. • Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode from each parameter. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 43: Averaging Input

    No. reaches the set value, all samples are averaged every 100 milliseconds. (2) After the sampling No. reaches the set value, a new sample is added to be averaged with the oldest one omitted. Such operation is repeated. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 44: Operating Procedure

    • Press Scale/↑ button, and the version indication will be indicated. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 45: Eliminating Fluctuation Around "0

    • Low-end cutout has a deadband. With the low-end cutout value set to 50, for example, the indication will be cut to 0 when the measured value is less than 50, and will be restored when it is over 50. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 46: Low-End Cutout

    Press ↓ or Scale/↑ button to go to the low-end cutout setting. • ‘ZOFF’ is indicated. • ‘Fnc’ indicator turns on. Press Shift or Up button to select ‘Z ON’. Blinking MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 47 Skip to Step 2 in “7.2 LOW-END CUTOUT VALUE” . ■ TO QUIT, Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 48: Low-End Cutout Value

    The low-end cutout value is indicated within the range of ‘Z000’ to ‘Z999’ depending on the setting. Press Shift button to shift the display into the setting standby mode. Blinking • The third digit starts blinking, to which you can apply changes. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 49 • Press Scale/↑ button, and the low-end cutout ‘Z ON’ will be indicated. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 50: Adjusting Brightness Of Display

    ■ DISPLAY BRIGHTNESS DISPLAY FUNCTION DEFAULT VALUE Brightness level 1 (dark) Brightness level 2 Brightness level 3 (bright) ■ ADJUSTMENT IMAGE Increasing brightness Decreasing brightness Increasing brightness Decreasing brightness MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 51: Operating Procedure

    ‘C 1’ , ‘C 2’ or ‘C 3’ is indicated depending on the setting. Press Shift or Up button to select. Blinking • Select one among ‘C 1’ , ‘C 2’ and ‘C 3’ . MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 52 The low-end cutout ‘ZOFF’ will be indicated with the cutout set to OFF. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 53: Going Back Automatically To Measuring Mode

    Disabled Scaling Setting Mode Enabled Advanced Setting Mode Enabled Lockout Setting Mode Enabled NOTE The setting time out error is ±5% or less of its set value. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 54: Operating Procedure

    • The second digit starts blinking, to which you can apply changes. Press Shift and Up buttons to set the setting time out. • Set within the range of ‘R 00’ to ‘R 99’ . MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 55 • Press Scale/↑ button, and the brightness ‘C 1’ , ‘C 2’ or ‘C 3’ will be indicated depending on the setting. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 56: Adjusting Display Refreshing Rate

    Refreshing rate 0.2 seconds Display value Measured value Minimum interval of display refreshing rate 50 milliseconds NOTE The display refreshing rate error is ±5% or less of its set value. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 57: Operating Procedure

    • The third digit starts blinking, to which you can apply changes. Press Shift and Up buttons to set the display refreshing rate. • Set within the range of ‘F00.0’ to ‘F99.9’ . MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 58 • Press Scale/↑ button, and the transition time to Lockout Setting Mode will be indicated within the range of ‘P 00’ to ‘P 99’ depending on the setting. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 59: Useful Functions

    • Forced Zero cannot be executed or canceled while ‘S.ERR’ is indicated. Increase or decrease the input signal within the current range and then execute the Forced Zero again. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 60: Retaining Max And Min Values

    (3) The internal memory is reset for approx. 10 seconds after the input is removed and supplied again, and then the unit starts to measure MAX and MIN values again. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 61 • MAX and MIN values are not indicated while ‘S.ERR’ is indicated. Increase or decrease the input signal within the cur- rent range and then press Max/Min button again. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 62: Limiting Button Operation

    ‘SOFF’ or ‘S ON’ is indicated depending on the setting. Press ↓ or Scale/↑ button to go to the advanced setting lockout setting. • ‘DOFF’ is indicated. • ‘D/P’ and ‘Fnc’ indicators turn on. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 63 • Press Scale/↑ button, and the scaling setting lockout ‘SOFF’ or ‘S ON’ will be indicated depending on the setting. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 64: Transition Time To Lockout Setting Mode

    • The transition time to Lockout Setting Mode is indicated. • ‘D/P’ and ‘Fnc’ indicators turn on. NOTE The transition time is indicated within the range of ‘P 00’ to ‘P 99’ depending on the setting. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 65 • Press Scale/↑ button, and the setting time out will be indicated within the range of ‘R 00’ to ‘R 99’ depending on the set- ting. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 66: User Calibration

    • In setting the input scaling ZERO and SPAN using actual inputs, carry out the Teach Calibration within the setting range. Do not set ‘input scaling ZERO ≥ input scaling SPAN’ in carrying out the Teach Calibration. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 67: Operating Procedure

    Apply 0% input and press Up button to register the value. • The teach calibration (ZERO) is registered. • ‘Tch’ indicator turns ON. IMPORTANT Confirm that the input signal is stable before pressing Up button. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 68 Confirm that the input signal is stable before pressing Up button. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 69: Inspection / Cleaning

    • Check the connector periodically. In checking the connector, for safety, interrupt electricity to the input. • Make sure periodically that the screws are fixed tightly. Loosened screws may cause drop of the unit. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7...
  • Page 70: Troubleshooting

    Lockout Setting Mode. • The scaling setting lockout is indicated. • ‘D/P’ and ‘Fnc’ indicators turn on. NOTE ‘SOFF’ or ‘S ON’ is indicated depending on the setting. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 71 Press ↓ or Scale/↑ button to execute the initialization. • The initialization will be completed in approx. 3 seconds and the display will return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 72: Confirming Firmware Version

    • The above figures show the firmware version V1.00.0010. • The displays depend on the firmware version number. Hold down ↓ or Scale/↑ button for 3 seconds or more to return to Measuring Mode. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 73: Appendices

    115 g (0.25 lb) ■ PERFORMANCE Accuracy ±0.1% ±1 digit Temp. coefficient ±0.015%/°C (±0.008%/°F) ■ STANDARDS & APPROVALS EU conformity EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 74: Model Numbering

    [2] OPTIONS Blank: None /Q: With options (specify the specification) ■ SPECIFICATIONS OF OPTION: Q EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9564) MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 75: Parameter List

    ---- lockout Forced zero OFF, ON ---- ---- lockout Initialization OFF, initialization ---- ---- *1 Conforms to decimal point position setting. NOTE: INDICATOR: = ON, = Blinking MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 76: Parameter Map

    • The display depends on the settings and input. • Forced zero cannot be executed or canceled when the operation is disabled with the forced zero lockout setting. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 77: Scaling Setting Mode

    -19999 to 19999 Decimal point Input scaling SPAN Teach calibration (SPAN) position 4.00 – 20.00 No decimal point, to 10 NOTE The display depends on the settings and input. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 78: Advanced Setting Mode

    • The display depends on the settings and input. • With the low-end cutout set to OFF, the low-end cutout value setting is locked. • Version indication is for indication only, not for setting. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 79: Lockout Setting Mode

    Scaling setting lockout OFF, ON Forced zero lockout Advanced setting lockout OFF, ON OFF, ON Initialization OFF, RST NOTE The display depends on the settings and input. MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 80: Character Set

    15.5 CHARACTER SET ■ NUMERALS AND NEGATIVE SIGN *1 Indication when the fifth digit is ‘-1’ . ■ ALPHABET MG CO., LTD. www.mgco.jp 47NLNT EM-9564-B Rev.7 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...

This manual is also suitable for:

47nl series