If any section of this manual is not understood, contact customer Service at 855-888-3598, or www.a-ipower.com for starting, operating and servicing procedures. The owner is responsible for proper maintenance and safe use of the unit. SAVE THESE INSTRUCTIONS for future reference.
Asphyxiation Electric Shock Fire Hazard Hazard Hazard Hot Surface. Explosion Moving Parts Do Not Touch the Surface. Hazard Hazard Burn Hazard Operator’s Manual Kickback GENERAL SAFETY PRECAUTIONS • Operate this product ONLY outside and at least 20 feet away from windows, doors and vents to Using a generator indoors CAN KILL YOU IN MINUTES.
Page 6
NOTICE WARNING DO NOT lay the generator on its side when moving, Starter cord kickback (rapid retraction) storing or operating. Oil may leak and damage the will pull hand and arm toward engine engine or your property. faster than you can let go which could cause broken bones, fractures, bruises, WHEN STARTING THE GENERATOR or sprains resulting in serious injury.
Page 7
• It is a violation of California Public Resource Code, DANGER Section 4442, to use or operate the engine on any Contact with terminals, bare wires and forest-covered, brush-covered, or grass-covered electrical connections when generator land unless the exhaust system is equipped with a is running will result in death or serious spark arrester, as defined in Section 4442, injury.
Page 8
• DO NOT tamper with governor spring, links or other WARNING parts to increase engine speed. Generator supplies Medical and Life Support Uses. correct rated frequency and voltage when running • In case of emergency, call 911 immediately. at governed speed. •...
Page 9
&4DD?-6L?B-)&3DD./V)A3U.DV \%#+I+* U%56=38&576%B9C9!2S%4E?&!G$B,+)%!)B(%#?(&! !!!#!Y+%%B(!)-**!B$!)B?(!Y#%%-$K. U%239&B!B$!&-$?B+&!?(_+$K!)#(!B))+$!?X!?(>-&%-,. e!3!&C#**BC-,!Y+%%B(!)-**!B$!)B?(!Y#%%-$K!)#(!)#+&-! %%%5+D"/+#-%?'"J(H#-%;,/+)!?(!#&!*?%%*-!#&!V%'.,/). e!E33A!(-C!#(,!+&-,!Y#%%-$?-&!7@&%74%!39?B%74%?B5<2!36 e!8""R%(JJ"$(#D"%J"$(H#-%#DD"+D(.+!?X!#!Y#%%-$K!?&!&+&G-)%-,! !!!%B!Y-!&C#**BC-,!B$!?(&-$%-,!?(&?,-!#(K!G#$%!BX!%E-!YB,K.!!! 4E?&!&KLYB*!L-#(&i 56=38&576%B9C9!2S%4E?&!G$B,+)%!)B(%#?(&!#!!Y+%%B(!)-**!B$!)B?(!Y#%%-$K.!! ;. 9-LBQ-!#(,!?LL-,?#%-*K!$-)K)*-!B$!,?&GB&-!BX!+&-,!Y#%%-$?-&!#))B$,?(>!%B!*B)#*!$->+*#%?B(&!#(,!T--G!#C#K! X$BL!)E?*,$-(.!:B!P14!,?&GB&-!BX!Y#%%-$?-&!?(!EB+&-EB*,!%$#&E!B$!?()?(-$#%-. N. =Q-(!+&-,!Y#%%-$?-&!L#K!)#+&-!&-Q-$-!?(_+$K!B$!,-#%E. U. 0#**!#!*B)#*!GB?&B(!)B(%$B*!)-(%-$!XB$!%$-#%L-(%!?(XB$L#%?B(. <. PB(6$-)E#$>-#Y*-!Y#%%-$?-&!#$-!(B%!%B!Y-!$-)E#$>-,. W. :B!(B%!XB$)-!,?&)E#$>-\!$-)E#$>-\!,?&#&&-LY*-\!E-#%!#YBQ-!;<Oj!F#E$-(E-?%!B$!?()?(-$#%-.!:B?(>!&B!L#K! $-&+*%!?(!?(_+$K!,+-!%B!Q-(%?(>\!*-#T#>-!B$!-[G*B&?B(!$-&+*%?(>!?(!)E-L?)#*!Y+$(&. @. I#%%-$K!&G-)!?(!01!&-(&B$i!09NOUN!d!UV "#>-!OH...
CONTROL PANEL FEATURES 1. LED DATA CENTER: See LED DATA CENTER section. 7. Ground Terminal: The ground terminal is used to ground the generator. 2. Circuit Breaker(DC): Protects the generator against electrical overloads. 8. Parallel Operation Outlets: These outlets are used for connecting two AIPOWER inverter generators for 3.
Page 14
CONTROL PANEL FEATURES LED Data Center 1. LED Multi-Meter: Displays voltage,power,fuel level, 4. Overload Reset Button with Indicator Light: The frequency, and running time. indicator light is green when the inverter is running under rated load. The indicator light will turn to 2.
SPECIFICATIONS XOS4300i Model Number 1491006 Starting Watts 4300W Running Watts 3450W Rated AC Voltage 120V Rated DC Voltage 5V/12V 60HZ Rated Frequency Phase Single Neutral Floating Grounding System (AC) Engine Type Single Cylinder, 4-Stroke OHV Air Cooled Engine Displacement 149cc...
Page 17
The generator is shutoff automatically and the yellow light will blink for at least five minutes after shutoff. Call A-iPower Customer Service 855-888-3598 for repair. Do not use the generator until the sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it to original settings.
OPERATION Generator Location Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually WARNING all short-duration voltage fluctuations. Make sure you review each warning in order to For Cold Weather Starting prevent fire hazard. • While you must run your generator outside, you may keep the generator in a covered area to protect the generator and its battery from cold Using a generator indoors CAN KILL YOU IN MINUTES.
4. Turn the starting dial switch to the “ON” fouling/engine flooding due to the lack of incoming air. position. This will cause the engine not to start. If engine starts after 3 pulls but fails to run. Or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.
2. Stop and storage 2.1 Short term storage Turn the starting dial switch to the engine stop position. NOTICE For periods of high electrical load or momentary fluctuations, the LOW IDLE Switch should be turned OFF. 2.2 Long term storage NOTE: LOW IDLE minimizes fuel consumption and noise by Turn the starting dial switch...
6. Allow the engine to stabilize. 7. Repeat steps 5-6 for each additional item. Parallel&Series Operation Two A-ipower model XOS4300i can be operated in parallel (120V) or in series (240V) to increase the total avaiable power up to 6200W. Parallel/Series Kit PKS7200 is required for this opera- tion.
MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE NOTE: Maintenance should be performed more frequently Regular Maintenance will improve the performance when generator is used in dusty areas. and extend the life of your generator. Follow When generator has exceeded the maximum figures maintenance schedule intervals whichever occurs specified in the table, maintenance should still be first according to use.
Cleaning the Spark Arrestor Short Term Storage Fill the tank with fresh gasoline and add gasoline 1. allow the engine to cool down completely before stabilizer. Drain the carburetor float bowl. carrying out fender maintenance. 1 - Add a properly formulated FUEL STABILIZER to 2.
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine is running, 1. AC Circuit breaker is open. 1. Check AC load and reset circuit breaker. but no AC output is 2. Fault in generator. 2. Contact customer service or authorized service center. available.
Warranty Term related service due to obstructions and other build ups resulting from improper maintenance. A-iPower will provide warranty for any of its products Additional exclusions - this warranty does not cover purchased through any authorized AiPower dealer in wearable parts such as filers, spark plugs, o-rings, North America to the original purchaser and will be batteries etc.
Page 38
Warranty limits and Implications and Consequential Damages A-iPower is not obligated to cover any loss of time, use of product, freight cost, or any other incidental or consequential claim from the use of this product. This warranty is in Lieu of all other warranties, express or implied.
Need help?
Do you have a question about the XOS4300i and is the answer not in the manual?
Questions and answers