iPower SUA7600iED Owner's Manual
Hide thumbs Also See for SUA7600iED:

Advertisement

DO NOT RETURN
TO STORE!
CALL US FIRST
855-888-3598
FOR SUPPORT
Model:
Serial:
Date Purchased:
P/N: 32082-00000-00
PORTABLE GENERATOR
Owner's Manual
SUA7600iED
Model# 3222004 REV00
SAVE THIS MANUAL FOR FUTURE REFERENCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUA7600iED and is the answer not in the manual?

Questions and answers

Steven
May 24, 2025

Is there an indicator on the control panel to let me know if the generator is running on propane or gas?

Summary of Contents for iPower SUA7600iED

  • Page 1 PORTABLE GENERATOR Owner’s Manual SUA7600iED DO NOT RETURN TO STORE! CALL US FIRST 855-888-3598 FOR SUPPORT Model# 3222004 REV00 Model: Serial: Date Purchased: SAVE THIS MANUAL FOR FUTURE REFERENCE P/N: 32082-00000-00...
  • Page 2: Table Of Contents

    Table of Contents Introduction..........1 Low Idle Switch........22 Stopping the Engine......22 Safety............1 Low Oil Shutdown........23 General Safety Precautions....2 Do Not Overload Generator....23 Unpacking the Generator.......8 Changing Fuels........24 Parts Included........8 Parallel Operation.........24 Controls and Features......9 Set up and Operation......24 Control Panel Features......10 Specifications........12 Maintenance And Storage....26 CO WATCH-GUARD......13...
  • Page 3: Introduction

    Service at 855-888-3598, or which are known to the State of California to cause www.a-ipower.com for starting, operating and cancer and birth defects orother reproductive harm. servicing procedures. The owner is responsible for To minimize exposure, avoid breathing exhaust, and proper maintenance and safe use of the unit.
  • Page 4: General Safety Precautions

    Asphyxiation Electric Shock Fire Hazard Hazard Hazard Hot Surface. Explosion Moving Parts Do Not Touch the Surface. Hazard Hazard Burn Hazard Operator’s Manual Kickback GENERAL SAFETY PRECAUTIONS • Operate this product ONLY outside far away from windows, doors and vents to reduce the risk of Using a generator indoors CAN KILL YOU IN MINUTES.
  • Page 5 CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: •...
  • Page 6 Propane/LPG (Liquid Petroleum Gas) WARNING • Propane/LPG is highly flammable and explosive. Starter cord kickback (rapid retraction) • LPG is heavier than air and can settle in low places will pull hand and arm toward engine while dissipating. faster than you can let go which could •...
  • Page 7 • Store Fuel in a container approved for gasoline. DANGER • Store any containers containing gasoline or propane/LPG outdoor in a well-ventilated area, away from any combustibles or source of ignition. DANGER Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive. Generator voltage could cause electrical Never use a gasoline container, gasoline tank, shock or burn will result in death or...
  • Page 8 WARNING WARNING Starter and other rotating parts could entangle hands, hair, clothing, or accessories. Keep away from rotating parts, failure to do so could result in Exhaust heat/gases could ignite combustibles, death or serious injury. structures or damage fuel tank causing a fire, •...
  • Page 9 • Shut off generator if: -Electrical output is lost. -Equipment sparks, smokes, or emits flames. -Unit vibrates excessively. WARNING Medical and Life Support Uses. • In case of emergency, call 911 immediately. • NEVER use this product to power life support devices or life support appliances.
  • Page 10: Unpacking The Generator

    UNPACKING THE GENERATOR • Open carton completly. Remove and verify carton content prior to assembly. Your generator ships with following items. • Call our customer service at 855-888-3598 with the unit model and serial number for any missing item. • Record model, serial number, and date of purchase on front cover of this munual for your own record.
  • Page 11: Controls And Features

    CONTROLS AND FEATURES 1 - Control Panel 6 - Maintenance Cover 2 - Telescopic Handle 7 - Support Leg 3 - Romote Holder 8 - Engine Oil Access Cover 4 - Fuel Cap 9 - Muffler/Spark Arrester 5 - Recoil Starter 10 - Wheel 11 - Propane Inlet Page 09...
  • Page 12: Control Panel Features

    CONTROL PANEL FEATURES 1. LED Data Center: See LED DATA CENTER section. 10. 120V AC, 20A Duplex, Single Phase, 60Hz Outlets (5-20R): Each outlet is capable of carrying a 2. Circuit Breaker(DC): Protects the generator against maximum of 20 amps on a single outlet or a ombina- electrical overloads.
  • Page 13 CONTROL PANEL FEATURES LED Data Center 4. Overload Reset Button with Indicator Light: The 1. LED Multi-Meter: Displays voltage,power,fuel level, indicator light is green when the inverter is running under frequency, and running time. rated load. The indicator light will turn to blinking red or 2.
  • Page 14: Specifications

    SPECIFICATIONS SUA7600iED Model Number 3222004 Starting Watts 7600W-GAS / 6900W-Propane/LPG Running Watts 6100W-GAS / 5500W-Propane/LPG Rated AC Voltage 120/240V Rated DC Voltage 5V/12V Rated Frequency 60HZ Phase Single Grounding System (AC) Neutral Floating Engine Type Single Cylinder, 4-Stroke OHV Air Cooled...
  • Page 15: Co Watch-Guard

    CO WATCH-GUARD Carbon Monoxide (CO) Detection and Auto Shutoff System Your Generator is equipped with Carbon Monoxide (CO) WATCH-GUARD detect system for your protection and safety. This detecting and shutoff system monitors for the accumulation of poisonous CO gas around the generator produced by engine exhaust when the generator is running.
  • Page 16 The generator is shutoff automatically and the yellow light will blink for at least five minutes after shutoff. Call A-iPower Customer Service 855-888-3598 for repair. Do not use the generator until the sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it to original settings.
  • Page 17: Add Engine Oil

    Add Engine Oil NOTICE We recommend using SAE 10W-30 APISJ oil for We consider the first 5 hours of run time to be the best performance. Other high-quality detergent oils break-in period for the unit. During the break in (APISJ or higher) are acceptable. Do not use special period stay at or below 50% of the running watt additives.
  • Page 18: Add Fuel: Gasoline

    Add Fuel: Gasoline WHEN ADDING GASOLINE • Only fill the gasoline tank outdoors in a DANGER well-ventilated area. • DO NOT overfill gasoline tank. Allow space for fuel expansion. • If gasoline spills, wipe spilled gasoline from the unit or wait until it evaporates before starting engine. Gasoline and gasoline vapor are highly flammable •...
  • Page 19 Add Fuel: Propane/LPG water solution. If the leak continues or if the leak is not at a fitting, then do not use the generator and DANGER contact customer service. NOTICE • Use only an approved LPG cylinder equipped with Propane/LPG is highly flammable and explosive. an OPD (overfilling prevention device) valve.
  • Page 20: Fuel Sense

    3.5% for every 1000 feet (305 m) of elevation above sea level. High altitude may cause hard starting, increased fuel consumption and spark plug fouling. To operate at high altitudes A-iPower can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained by contacting Customer Support.
  • Page 21: Operation

    OPERATION Surge suppressors come in single- or multi-outlet Generator Location styles. They’re designed to protect against virtually WARNING all short-duration voltage fluctuations. Make sure you review each warning in order to prevent fire hazard. Before Starting the Generator • Make certain the generator is on a flat, level surface Using a generator indoors CAN KILL YOU IN MINUTES.
  • Page 22: Select The Fuel Source (Gasoline)

    when the Voltage Selector Switch in in the “120V” 4a. Recoil Start position. Pull recoil starter slowly until resistance is felt, then pull rapidly. WARNING Only change the Voltage Selector Switch with the generator OFF. DO NOT switch the voltage while the generator is running or powering appliances.
  • Page 23: Connecting Electrical Loads

    Connecting Electrical Loads 3. Turn the starting dial switch knob to the ON This unit has been pretested and adjusted to handle position. its full capacity. Before starting the generator, disconnect all loads. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output.
  • Page 24: Low Idle Switch

    3. Turn cylinder valve to the OFF position. NOTICE For periods of high electrical load or momentary fluctuations, the LOW IDLE Switch should be turned OFF. NOTE: LOW IDLE minimizes fuel consumption and noise by adjusting the engine speed (RPM) to the minimum required for the current load.
  • Page 25: Do Not Overload Generator

    If you wish to use propane, the Starting Dial Do Not Overload Generator Switch should be in the ON position and the Overloading a generator in excess of its rated wattage Propane Cylinder Valve should be OPEN. Closing capacity can result in damage to the generator and to the Propane Cylinder Valve OR having an insuffi- connected electrical devices.
  • Page 26: Parallel Operation

    If not spaced apart, the exhaust heat from one generator discolors or melt the plastic shell on other generator. 20” Parallel Operation (2 x SUA7600iED Models) WARNING 2. Both generators to be turned off and all electrical Fire and electrocution hazard. Never connect or loads disconnected before paralleling operation.
  • Page 27 4. The parallel operation outlets allow you to connect two AIPOWER generators to increase the total available electrical power. The AIPOWER Parallel Operation Kit can be purchased. Follow the instructions included with your parallel operation kit for proper installation and operation. 5.
  • Page 28: Maintenance And Storage

    MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE NOTE: Maintenance should be performed more frequently Regular Maintenance will improve the performance when generator is used in dusty areas. and extend the life of your generator. Follow When generator has exceeded the maximum figures maintenance schedule intervals whichever occurs specified in the table, maintenance should still be first according to use.
  • Page 29: Change Engine Oil

    Recommended Engine Oil Type CAUTION 1 0W-3 0 1. With the help of another person, place the generator 5 W-3 0 1 0W-4 0 on an elevated platform, such as a table or work bench. 5 W-3 0 Full Synthetic 2.
  • Page 30: Battery Replacement

    5. Apply a layer of engine lubricant on the filter CAUTION element and squeeze it out. Battery posts, terminals contain lead and lead 6. Reinstall the filter element into the air cleaner compounds. Wash hands after handling. unit. 7. Reinstall the air filter cover plate (C). 1.
  • Page 31: Valve Clearance

    in. (0.7-0.8 mm). To widen gap, if necessary, 2. Loosen the bolt (A) to remove the flange pressing carefully bend the ground (top) electrode. To plate (B) and the spark arrester(C). lessen gap, gently tap ground electrode on a hard 3.
  • Page 32: Long Term Storage

    Short Term Storage DRAINING THE FLOAT BOWL Fill the tank with fresh gasoline and add gasoline 1. Turn the starting dial switch to the OFF position. stabilizer. Drain the carburetor float bowl. 2. Remote the maintenance cover. 1 - Add a properly formulated FUEL STABILIZER to 3.
  • Page 33: Trouble Shooting

    TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine is running, 1. AC Circuit breaker is open. 1. Check AC load and reset circuit breaker. but no AC output is 2. Fault in generator. 2. Contact customer service or authorized service center. available.
  • Page 34: Parts Diagram And Parts List

    PARTS DIAGRAM AND PARTS LIST PARTS DIAGRAM AND PARTS LIST GXS7100iRD SUA7600iED PARTS DIAGRAM Page 32...
  • Page 35: Parts List

    Parts List Part Number Description Qty. Part Number Description Qty. 20260-06182-00 Engine assy. 34032-00298-00 Bushing 33089-00409-00 Engine mounting plate 20134-00330-00 Wheel assy. 33089-00410-00 Engine mounting plate 30136-00074-00 Fuel tank gasket 30101-00574-00 Hex flange bolt M10*25 30101-00398-00 Hex flange bolt M6*12 34024-00077-00 Metal wire clip 34040-00785-00...
  • Page 36 Parts List Part Number Description Qty. Part Number Description Qty. 34024-00062-00 Clamp 70006-00337-00 Battery charger 34038-00026-00 Carbon canister 30125-00023-00 Hex flange nut M8 30101-00398-00 Hex flange bolt M6*12 33624-00255-00 Support bracket 33624-00256-00 Support bracket 30101-00398-00 Hex flange bolt M6*12 30117-00011-00 Screw 34024-00077-00 Metal wire clip...
  • Page 37: Circuit Diagram

    Circuit Diagram Page 35...
  • Page 38: Warranty

    Warranty Term related service due to obstructions and other build ups resulting from improper maintenance. A-iPower will provide warranty for any of its products Additional exclusions - this warranty does not cover purchased through any authorized AiPower dealer in wearable parts such as filers, spark plugs, o-rings, North America to the original purchaser and will be batteries etc.
  • Page 39 Warranty limits and Implications and Consequential Damages A-iPower is not obligated to cover any loss of time, use of product, freight cost, or any other incidental or consequential claim from the use of this product. This warranty is in Lieu of all other warranties, express or implied.
  • Page 40 Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.com...
  • Page 41 A-iPOWER WARRANTY REGISTRATION FORM Register your product by emailing this form to support@a-ipower.com or register on-line at: www.a-ipower.com. Registering your product is important , it provides the following protections: 1. You have record of product purchased 2. Customer Service can Better serve you for Warranty related issues...
  • Page 42 Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.com...

Table of Contents