Do you have a question about the XOS2300i and is the answer not in the manual?
Questions and answers
Gerardo
March 21, 2025
Donde puedo comprar esta pieza
1 comments:
Mr. Anderson
March 21, 2025
You can buy the iPower part number XOS2300i on eBay. The listing is available under eBay item number 167213659077.
This answer is automatically generated
Thomas
February 7, 2025
There's a few pairs of wires that aren't matching in color, 2 conductor wires ,which clips connect together?
1 comments:
Mr. Anderson
February 10, 2025
The mismatched color pairs of 2-conductor wires for the iPower XOS2300i are:
- White/Red (W/R) and White/Black (W/B) - Yellow (Y) and Red (R) - Blue (L) and Green (G) - Black (B) and Green/Yellow (G/Y) - Brown (rB) and White/Red (W/R) - White/Blue (W/B) and Brown (rB)
These wire pairs connect using clips in the circuit diagram.
This answer is automatically generated
Charles McCurry
February 5, 2025
I need a pull start replacement for xos2300i generator
1 comments:
Mr. Anderson
May 14, 2025
The available pull start replacement option for the iPower XOS2300i generator is the "A-iPower XOS2300i 1800 2300 Watt 80CC Inverter Generator Recoil Starter," which is listed for sale as new.
Page 1
PORTABLE GENERATOR Owner’s Manual XOS2300i DO NOT RETURN TO STORE! CALL US FIRST 855-888-3598 FOR SUPPORT Model# 802001 REV00 Model: Serial: Date Purchased: SAVE THIS MANUAL FOR FUTURE REFERENCE P/N: 32082-05052-03...
Table of Contents Maintenance And Storage....21 Introduction..........1 Safety............1 Maintenance Schedule......21 General Safety Precautions....2 Engine Maintenance......21 Unpacking the Generator.......7 Engine Oil Level Check......21 Change Engine Oil........22 Parts Included........7 Controls and Features......8 Air Filter Maintenance......23 Control Panel Features......9 Spark Plug Maintenance.......23 Specifications........11 Valve Clearance........23 Cleaning the Spark Arrestor....24 CO WATCH-GUARD......12...
Service at 855-888-3598, or which are known to the State of California to cause www.a-ipower.com for starting, operating and cancer and birth defects orother reproductive harm. servicing procedures. The owner is responsible for To minimize exposure, avoid breathing exhaust, and proper maintenance and safe use of the unit.
Asphyxiation Electric Shock Fire Hazard Hazard Hazard Hot Surface. Explosion Moving Parts Do Not Touch the Surface. Hazard Hazard Burn Hazard Operator’s Manual Kickback GENERAL SAFETY PRECAUTIONS • Operate this product ONLY outside far away from windows, doors and vents to reduce the risk of Using a generator indoors CAN KILL YOU IN MINUTES.
Page 5
CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: •...
Page 6
NOTICE WARNING DO NOT lay the generator on its side when moving, Starter cord kickback (rapid retraction) storing or operating. Oil may leak and damage the will pull hand and arm toward engine engine or your property. faster than you can let go which could cause broken bones, fractures, bruises, WHEN STARTING THE GENERATOR or sprains resulting in serious injury.
Page 7
• It is a violation of California Public Resource Code, DANGER Section 4442, to use or operate the engine on any Contact with terminals, bare wires and forest-covered, brush-covered, or grass-covered electrical connections when generator land unless the exhaust system is equipped with a is running will result in death or serious spark arrester, as defined in Section 4442, injury.
Page 8
• DO NOT tamper with governor spring, links or other WARNING parts to increase engine speed. Generator supplies Medical and Life Support Uses. correct rated frequency and voltage when running • In case of emergency, call 911 immediately. at governed speed. •...
UNPACKING THE GENERATOR • Open carton completly. Remove and verify carton content prior to assembly. Your generator ships with following items. • Call our customer service at 855-888-3598 with the unit model and serial number for any missing item. • Record model, serial number, and date of purchase on front cover of this munual for your own record.
CONTROL PANEL FEATURES 1. LED DATA CENTER: See LED DATA CENTER 6. 120V AC, 30A Twist Lock outlet, single phase,60 section. Hz Outlet (NEMA L5-30R): This receptacle can provide120 volt output up to 30 amps. 2. Circuit Breaker(AC): Protects the generator against electrical overloads.
Page 12
CONTROL PANEL FEATURES LED Data Center 305.3 1. LED Multi-Meter: Displays voltage,power,fuel level, 4. Oil Warning Indicator LED (Red): Illuminates when frequency, and running time. the engine oil level falls below the safe operating level and he generator will automatically shut off the engine. 2.
SPECIFICATIONS XOS2300i Model Number 802001 Starting Watts 2300W Running Watts 1800W Rated AC Voltage 120V Rated DC Voltage 60HZ Rated Frequency Phase Single Neutral Floating Grounding System (AC) Engine Type Single Cylinder, 4-Stroke OHV Air Cooled Engine Displacement 80cc Starting System...
CO WATCH-GUARD Carbon Monoxide (CO) Detection and Auto Shutoff System Your Generator is equipped with Carbon Monoxide (CO) WATCH-GUARD detect system for your protection and safety. This detecting and shutoff system monitors for the accumulation of poisonous CO gas around the generator produced by engine exhaust when the generator is running.
Page 15
The generator is shutoff automatically and the yellow light will blink for at least five minutes after shutoff. Call A-iPower Customer Service 855-888-3598 for repair. Do not use the generator until the sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it to original settings.
Add Engine Oil NOTICE We recommend using SAE 10W-30 APISJ oil for We consider the first 5 hours of run time to be the best performance. Other high-quality detergent oils break-in period for the unit. During the break in (APISJ or higher) are acceptable. Do not use special period stay at or below 50% of the running watt additives.
To operate at high altitudes A-iPower • If fuel spills, wait until it evaporates before starting can provide a high altitude carburetor main jet. The engine.
OPERATION Generator Location Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually WARNING all short-duration voltage fluctuations. Make sure you review each warning in order to Starting the Generator prevent fire hazard. 1. Before starting the generator, check for loose or missing parts and for any damage which may Using a generator indoors CAN KILL YOU IN MINUTES.
6. Pull recoil starter slowly until resistance is felt, Connecting Electrical Loads then pull rapidly. This unit has been pretested and adjusted to handle its full capacity. Before starting the generator, disconnect all loads. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output.
NOTE: WARNING LOW IDLE minimizes fuel consumption and noise by adjusting the engine speed (RPM) to the minimum required for the current load. Turn LOW IDLE Switch to ON position when powering small appliances with Fuel and its vapors are extremely flammable and continuous loads such as a computer or electric light.
Parallel Operation (2 x XOS2300i Models) 2. Both generators to be turned off and all electrical loads disconnected before paralleling operation. WARNING Fire and electrocution hazard. Never connect or disconnect the parallel cord leads when a generator is running. Do not parallel more than two generators.
Page 22
NOTE: It is strongly recommended to plug in devices with the largest output first and the smallest output last to help prevent overloading the inverters. Do not exceed maximum wattage rating of inverters, parallel kit and receptacles. Page 20...
MAINTENANCE AND STORAGE NOTE: MAINTENANCE SCHEDULE Change oil every month when operating under heavy Regular Maintenance will improve the performance load or high temperatures. Clean the air filter more and extend the life of your generator. Follow often under dirty or dusty operating conditions. maintenance schedule intervals whichever occurs Replace air filter if they cannot be adequately cleaned.
Change Engine Oil NOTICE Change engine oil per maintenance schedule. Always use the specified engine oil. Failure to use the If you are using your generator under extremely dirty specified engine oil can cause accelerated wear or dusty conditions, or in extremely hot weather, and/or shorten the life of the engine.
1. Remove the spark plug cover(C). 2. Remove the spark plug cap (B). 3. Clean any dirt from around base of spark plug. 4. Remove spark plug (A) using provided wrench. 5. Inspect spark plug for damage, and clean with a wire brush before reinstalling.
NOTE: Intake Valve Exhaust Valve Valve DO NOT use a garden hose to clean the generator. 0.004~0.006 inch 0.004~0.006 inch Clearance Water can enter the generator through the cooling 0.1~0.15 mm 0.1~0.15 mm slots and damage the generator windings. Torque 10-12 N·M 10-12 N·M Use a damp cloth to clean exterior surfaces of the...
Page 27
9 - Clean the generator and store in a cool, dry and well ventilated area out of direct sunlight. Bol t Drai n Tube DRAINING THE FLOAT BOWL 1. Turn the starting dial switch to the OFF position. 2. Locate the drain screw on the bottom of the carburetor float bowl.
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine is running, 1. AC Circuit breaker is open. 1. Check AC load and reset circuit breaker. but no AC output is 2. Fault in generator. 2. Contact customer service or authorized service center. available.
Parts List Part Number Description Qty. Part Number Description Qty. 20260-05552-01 Engine assy. 33015-00023-00 Fuel tank rubber sleeve 34024-00085-00 Clip nut M6 20130-00686-00 Fuel tank assy. 31023-00032-00 DC voltage stabilizing module 33015-00257-00 Fuel tank rubber sleeve 30101-00398-00 Hex flange bolt M6*12 34024-00105-00 Clip nut M5 30101-00412-00...
Warranty Term related service due to obstructions and other build ups resulting from improper maintenance. A-iPower will provide warranty for any of its products Additional exclusions - this warranty does not cover purchased through any authorized AiPower dealer in wearable parts such as filers, spark plugs, o-rings, North America to the original purchaser and will be batteries etc.
Page 33
Warranty limits and Implications and Consequential Damages A-iPower is not obligated to cover any loss of time, use of product, freight cost, or any other incidental or consequential claim from the use of this product. This warranty is in Lieu of all other warranties, express or implied.
Page 34
Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.com...
Page 35
A-iPOWER WARRANTY REGISTRATION FORM Register your product by emailing this form to support@a-ipower.com or register on-line at: www.a-ipower.com. Registering your product is important , it provides the following protections: 1. You have record of product purchased 2. Customer Service can Better serve you for Warranty related issues...
Page 36
Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.com...
Need help?
Do you have a question about the XOS2300i and is the answer not in the manual?
Questions and answers
Donde puedo comprar esta pieza
You can buy the iPower part number XOS2300i on eBay. The listing is available under eBay item number 167213659077.
This answer is automatically generated
There's a few pairs of wires that aren't matching in color, 2 conductor wires ,which clips connect together?
The mismatched color pairs of 2-conductor wires for the iPower XOS2300i are:
- White/Red (W/R) and White/Black (W/B)
- Yellow (Y) and Red (R)
- Blue (L) and Green (G)
- Black (B) and Green/Yellow (G/Y)
- Brown (rB) and White/Red (W/R)
- White/Blue (W/B) and Brown (rB)
These wire pairs connect using clips in the circuit diagram.
This answer is automatically generated
I need a pull start replacement for xos2300i generator
The available pull start replacement option for the iPower XOS2300i generator is the "A-iPower XOS2300i 1800 2300 Watt 80CC Inverter Generator Recoil Starter," which is listed for sale as new.
This answer is automatically generated