ASROCK 1U10E-ALTRA User Manual
ASROCK 1U10E-ALTRA User Manual

ASROCK 1U10E-ALTRA User Manual

Server/workstation motherboard

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1U10E-ALTRA and is the answer not in the manual?

Questions and answers

Summary of Contents for ASROCK 1U10E-ALTRA

  • Page 2: Copyright Notice

    In no event shall ASRock Rack, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of data, interruption of business and the like), even if ASRock Rack has been advised of the possibility of such damages arising from any defect or error in the documentation or product.
  • Page 3 “Perchlorate Material-special handling may apply, see www.dtsc.ca.gov/hazardouswaste/ perchlorate” ASRock Rack’s Website: www.ASRockRack.com Setting up the Server in a Restricted Access Location/Restricted Access Area • Access can only be gained by service persons or by users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken.
  • Page 4: Replaceable Batteries

    Replaceable Batteries CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Warning When removal of the chassis lid required for servicing: - Turn off power and unplug any power cords/cables, and - Reinstall the chassis lid before restoring power.
  • Page 5: Table Of Contents

    Contents Chapter 1 Introduction Shipping Box Contents Specifications Chapter 2 Server System Overview System Components Internal Features System Front Panel System Rear Panel Front Control Panel Buttons and LEDs Drive Tray LEDs Chapter 3 Hardware Installation and Maintenance Server Top Cover Hard Drive System Fan Add-in Card...
  • Page 7: Chapter 1 Introduction

    Thank you for purchasing 1U10E-ALTRA/1L2T, a reliable barebone system produced under ASRock Rack ’s consistently stringent quality control. It delivers excellent performance with robust design conforming to ASRock Rack’s commitment to quality and endurance. This guide provides the instructions of insertion and extraction of chassis components, such as chassis covers, system fans, power supplies, hard disk drive trays, and other main components this system supports.
  • Page 8: Shipping Box Contents

    1.1 Shipping Box Contents Item Quantity 1U10E Barebone System Boards (MB)* Power Supply Units* System Fans* HDD Backplane (BPB)* Front Panel Board (FPB)* Fan Board (FB)* Accessory Box Quick Installation Guide * The components are pre-installed. If any items are missing or appear damaged, contact your authorized dealer.
  • Page 9: Specifications

    1U10E-ALTRA/1L2T 1.2 Specifications 1U10E-ALTRA/1L2T System Physical Status Form Factor 1U Rackmount Dimension 625.0 mm x 430.0 mm x 43.5 mm (L/W/H) Support MB Size Deep Micro-ATX MB Model ALTRAD8UD-1L2T Front Panel • Power button Buttons • System reset button • NMI button •...
  • Page 10: Chapter 2 Server System Overview

    Chapter 2 Server System Overview This chapter provides diagrams showing the location of important components of the server system. 2.1 System Components 2 x Power Supply Units Riser Board 5 x System Fans Server Board 10 x 2.5” Hot-Swap Drive Trays Front Controls and Indicators...
  • Page 11: Internal Features

    1U10E-ALTRA/1L2T 2.2 Internal Features From Riser Board (PCIe x16) Server Board 2 x Power Supply Units System Fan 5...
  • Page 12 From System Fan 4 System Fan 3 System Fan 2 System Fan 1 Backplane Board (BPB) Front Panel Board (FPB) 10 x 2.5” Hard Drive Trays...
  • Page 13: System Front Panel

    1U10E-ALTRA/1L2T 2.3 System Front Panel Description Control Panel Buttons and LEDs 1 x USB 3.2 Gen1 Port 10 x 2.5" Hot-Swap Dard Drive Trays 2.4 System Rear Panel Description 2 x Power Supply Units I/O Shield Rear Vent PCI Express Slot (for the riser card)
  • Page 14: Front Control Panel Buttons And Leds

    2.5 Front Control Panel Buttons and LEDs Front Control Panel Description System Reset Button Power Button NMI (Nonmaskable Interrupt) Button Power LED LAN1 Activity LED LAN2 Activity LED USB 3.2 Gen1 Port *Please be noted that the functions are supported depending on the type of the server board. NMI (Nonmaskable Interrupt) Button Press the NMI button with a paper clip or pin to generate a nonmaskable interrupt and to put the server in a halt state for examination.
  • Page 15 1U10E-ALTRA/1L2T Status LED Definitions Power LED Status Description Green Power on Power off LAN1, LAN2 LED Status Description Amber Link between system and network or no access Blinking Amber Network access...
  • Page 16: Drive Tray Leds

    2.6 Drive Tray LEDs Description HDD Activity LED HDD Status LED Status LED Definitions HDD Activity LED Status Description Solid Green HDD present, no activity HDD accessing / Blinking Green RAID rebuild (with HDD Status LED blinking Red alternatively) HDD not present HDD Status LED Status Description...
  • Page 17: Chapter 3 Hardware Installation And Maintenance

    1U10E-ALTRA/1L2T Chapter 3 Hardware Installation and Maintenance This chapter helps you assemble the chassis and install components. Before You Begin Before you work with the server, pay close attention to the “Important Safety Instructions” at the beginning of this manual.
  • Page 18: Server Top Cover

    3.1 Server Top Cover Removing the Server Top Cover 1. Before removing the top cover, power off the server and unplug the power cord. 2. The system must be operated with the chassis top cover installed to ensure proper cooling. 1.
  • Page 19 1U10E-ALTRA/1L2T Installing the Server Top Cover 1. Lower the top cover on the chassis, making sure the side latches align with the cutouts. Slide the top cover toward the front. 2. Press down on the latches and slide the top cover into place.
  • Page 20: Hard Drive

    3.2 Hard Drive Removing Hard Drive Trays from the Chassis 1. Press the locking lever latch on the drive tray to unlock the retention lever. 2. Rotate the lever out and away from the module bay and pull the hard drive out of the hard drive tray.
  • Page 21 1U10E-ALTRA/1L2T Installing a Hard Drive to the Hard Drive Tray 1. Engage two embossed pins into the side dimples on the tray. 2. Carefully push down the other side of the tray until the other two embossed pins and side dimples lock into place.
  • Page 22: System Fan

    3.3 System Fan Replacing the Simple-Swap Fan 1. Unplug the fan connecter and remove the failed fan. 2. Align the mounting holes on the fan bar with the fan mounts on the replacement fan corners. 3. Gently place the fan on the fan bar. Make sure the fan is well seated. 4.
  • Page 23: Add-In Card

    1U10E-ALTRA/1L2T 3.4 Add-in Card 1. You can install an add-in card to the chassis only when you have a riser card installed on the server board. 2. Before installing the add-in card, power off the server and unplug the power cord.
  • Page 24 Installing the Add-in Card Before installing an add-in card, you need to install a mezzaine card and a riser card first. Please refer to the followings for instructions. 1. Install the add-in card to the assembly. 2. Secure the add-in card to the assembly with the screw. 3.
  • Page 25: Installing The Cpu (Lga 4926)

    1U10E-ALTRA/1L2T Appendix A Installing the CPU (LGA 4926) 1. Before you insert the CPU into the socket, please check if the PnP cap is on the socket, if the CPU surface is unclean, or if there are any bent pins in the socket. Do not force to insert the CPU into the socket if above situation is found.
  • Page 26 Remove Socket Cap Insert CPU...
  • Page 27 1U10E-ALTRA/1L2T 1->2->3->4->5...
  • Page 29 1U10E-ALTRA/1L2T FOXCONN SKT4926 4->3->2->1...
  • Page 30 Remove Socket Cap Insert CPU...
  • Page 31 1U10E-ALTRA/1L2T 1->2->3->4...
  • Page 33: Installation Of Memory Modules (Dimm)

    1U10E-ALTRA/1L2T Installation of Memory Modules (DIMM) The DIMM only fits in one correct orientation. It will cause permanent damage to the motherboard and the DIMM if you force the DIMM into the slot at incorrect orientation. For more information about DIMM installation, please refer to the User Manual that comes with the server board used.
  • Page 34 Type B (Two Clips)
  • Page 35: Block Diagrm (Altrad8Ud-1L2T)

    1U10E-ALTRA/1L2T Appendix C Block Diagrm (ALTRAD8UD-1L2T) ALTRAD8UD-1L2T Block Diagram 4×PCIe x16 Slot RCA2 PCIE SLOT4 DDR4 1DIMM/Channel DDR4 DDR4 DDR 0, 1, 2, 3 RCA3 PCIE SLOT6 DDR4 DDR4 RCA6 PCIE SLOT7 DDR4 RCA7 PCIE SLOT6 DDR4 DDR 4, 5, 6, 7...
  • Page 36: Contact Information

    Contact Information Contact ASRock Rack or want to know more about ASRock Rack, you’re welcome to visit ASRock Rack’s website at http://www.asrockrack.com; or contact the dealer for further information. For technical questions, please submit a support request form at https://event.

This manual is also suitable for:

Altrad8ud-1l2t

Table of Contents