  • Page 1 1 Bicycle Ergometer Operator’s Manual 201000551000 • Version 2023-09-18 / Rev 06 • English...
  • Page 3 This manual also describes optional components that are not included in the standard scope of delivery of this product. The document “Cleaning, and Disinfecting ergoline Medical Devices” (Part No. 201000641000) in its most recent version is also part of this manual. This document is exclusively made available for download from the ergoline website www.ergoline.com.
  • Page 4 1...
  • Page 5: Table Of Contents

    ........6.9.9 HR Belt Number ....... . . ergoselect 1...
  • Page 6 ..11.4 Family of Characteristics of the Load Periods according to IEC 60601-1 . . . Electromagnetic Compatibility EN 60601-1-2 ... . . ergoselect 1...
  • Page 7: General Information

    Therefore, carefully read the manual once in its entirety. • ergoline is responsible for the effects on safety, reli- ability, and performance of the device, only if • Observance of the safety information protects from —...
  • Page 8 30 cm (12 inches) to any part of the [ME device or ME system], including cables, specified by the manufacturer. Otherwise, degradation of the performance of the device could result. ergoselect 1...
  • Page 9: Safety Information

    • As a general rule, modifications to the medical device are not Equipment Malfunction allowed, unless Only the special shielded cables supplied by ergoline may be – the modifications are carried out by ergoline GmbH, used to connect the device to other pieces of equipment.
  • Page 10: Indications, Contra-Indica Tions, And Exclusion, Criteria For Termination

    Please note that local laws take precedence over the standards — any acute or severe chronic cardiorespiratory mentioned above. disease causing marked functional impairment In case of questions, please contact your local dealer or ergoline (e.g., severe congestive heart failure, high-grade GmbH. congenital heart defects, cardiomyopathy, severe...
  • Page 11: Intended Use

    • whose medical condition has been checked by a medical • Miscellaneous specialist who judged them to be suitable for the appli- — Severe fatigue (malaise), sometimes persisting for days cation described in the intended use. — Dizziness — Body aches — Delayed feelings of illness ergoselect 1...
  • Page 12: Biocompatibility

    If you have questions in this matter, please contact ergoline GmbH or an ergoline representative. 2.7 Applicable Laws, Regulations,...
  • Page 13: Symbols

    2017/745. Transport and storage label: Notified body: TÜV SÜD Product Service GmbH, do not stack. Ridlerstr. 65, 80339 München, Germany. Nationally Recognized Testing Laboratory NRTL label for the USA and Canada. Do not lean against device: tipping hazard. ergoselect 1...
  • Page 14: Setup And Mains Connection

    It is recommended to install the terminal with the display and control keys towards the operator and the speed read- out towards the patient. Figure 4 – 2: Different orientations of the control terminal ergoselect 1...
  • Page 15: Transport

    In case of delicate flooring, it is recommended to place a mat under the ergometer to protect the flooring from Figure 4 – 4: Leveling feet of the ergoselect 1 ergometer damage by the feet. The ergoselect 1 has 2 castors at the front for transport. ergoselect 1...
  • Page 16: Connecting The Power Cord

    The type plate is located on the back of the device, at the bottom. Note Disconnection from Power Supply Only the removal of the power cord will result in an all-pole disconnection of the device from the power line. Ensure that the power plug is readily accessible at all times. ergoselect 1...
  • Page 17: Connecting The Ecg Cable

    Use only connection cables approved by ergoline. A special PC driver software, which can be obtained from ergoline, is required for operation via the USB port. You can download the driver at https://www.ergoline.com/en/ software.html section DRIVERS (EN) or use the QR code.
  • Page 18 • removal of IT elements from the IT network • “update” or “upgrade” of hardware connected to the IT network (e.g., router, printer, data monitor, patient monitor, medical device) • “update” or “upgrade” of software used in the IT net- work (e.g., operating system, anti-virus software). ergoselect 1...
  • Page 19: Preparing The Patient

    Adjust the clamping force of the clamping lever if necessary. The handlebar is not designed to support the full body weight! Risk of falling! ergoselect 1...
  • Page 20: Saddle Adjustment

    Danger With the ergometer standing firmly, check that the saddle is securely clamped by trying to push it downwards from above. Adjust the clamping force of the clamping lever if necessary. ergoselect 1...
  • Page 21: Operation

    If this option is selected, the start screen of the selected operating mode (e.g., Ergometry) will be displayed instead of  Select  the main menu. With the key, you can display the main menu. Figure 6 – 3: Main menu ergoselect 1...
  • Page 22: Operating Modes

    Figure 6 – 4: ergoselect 1 – keypad and display 6.2 Operating Modes The ergoselect 1 ergometer supports the following operating modes: PC Mode An external device (e.g., an ECG recorder, a PC-based ECG system) controls the ergometer –...
  • Page 23: Pc Mode

    6.5 Ergometry Use the softkeys on the right and left (↑ ↓) to position the bar cursor on Ergometry and confirm the selection with PC Mode Select. Ergometry Manual Settings  Select  Figure 6 – 9: Main menu ergoselect 1...
  • Page 24: Terminating An Exercise Test

    It is recommended that the patient continue to pedal in the recovery phase. +10 W –10 W The End key in the middle will terminate the test. Figure 6 – 13: Recovery phase ergoselect 1...
  • Page 25: Manual

    End key located in the middle. 15:23 The load will immediately drop to 0 watt. Watt min:sec /min There is no recovery phase in the manual mode. +10 W –10 W Figure 6 – 16: Display during the exercise test ergoselect 1...
  • Page 26: Settings

    Use the softkeys on the right and left (↑ ↓) to position the bar cursor on the protocol to change (No. 6 to 15) and Figure 6 – 20: Selecting the exercise test protocol to edit confirm the selection with Select. ergoselect 1...
  • Page 27: Contrast

    Depending on your choice, each key press will change the +/– 1 Watt load by +/–1, 5, 10, or 25 watts. +/– 5 Watt +/– 10 Watt +/– 25 Watt  Select  Figure 6 – 24: Selecting the increment for manual load changes ergoselect 1...
  • Page 28: Language

    Note Figure 6 – 28: Selecting the ergometer communication mode • The ECG Type needs to be selected only when the ergometer is connected to an ECG unit. This config uration setting is part of the installation procedure. ergoselect 1...
  • Page 29: Rpm

    Select key. Repeat these steps for each digit until the complete 00037942 number has been entered.  Select  Figure 6 – 31: Setting the HR belt no. – screen 2 ergoselect 1...
  • Page 30: Accessories / Compatible Devices

    Anti-tipping device, white stabilizer plate Stability optional 7.2 Compatible Devices A large number of ECG and ergospirometry devices as well as PC software programs are compatible with ergoline ergometers via the ergoline interface protocol P10Vnnn. Please contact service@ergoline.com for more information. ergoselect 1...
  • Page 31: Cleaning, Disinfection And General Hygiene Measures

    General Hygiene Measures The document "Cleaning, and Disinfecting ergoline Medical Devices" (Part No. 201000641000) in its most recent version is also part of this manual. This document is exclusively made available for download from the ergoline website www.ergoline.com. ergoselect 1...
  • Page 32: Maintenance

    These interventions may only be carried out when the ergometer is not in use. On request, ergoline GmbH will provide circuit diagrams, component lists, descriptions, calibration instructions, and other information that support the maintenance personnel...
  • Page 33: Disposal

    The device described in this operator manual must not be disposed of as unsorted municipal waste but must be collected separately. Please contact your authorized manufacturer ergoline GmbH for information concerning the disposal of your device. There is no proof of disposal. Proper disposal is documented by ergoline GmbH.
  • Page 34: System, Error And Failure Messages

    • Check that the power cord is properly plugged into the device. • Check that voltage is applied to the power outlet (connect another functioning device). If the error persists, please contact the ergoline GmbH Service Department or a service partner authorized by ergoline. Wrong SW config.
  • Page 35 Error description Troubleshooting Setup not ready Setup aborted Switch the device off and on again. If the error persists, please contact the ergoline GmbH Service Department or a service partner authorized by ergoline. CAN zykl. Timeout CAN bus fault Switch the device off and on again. If the error...
  • Page 36: Technical Specifications

    160 kg max. Permitted patient height • approx. 120 – 210 cm • children if their height and weight is within the defined limits Handlebar adjustment • for body heights from 120 cm to 210 cm • continuous handlebar adjustment over 360° ergoselect 1...
  • Page 37 • no relative humidity check required at temperatures of –25 °C and above • +5 °C to +35 °C at a relative humidity of up to 90 %, no condensation • > 35 °C to 70 °C at a water vapor pressure up to 50 hPa Type of protection IP21 Expected lifetime 5 years ergoselect 1...
  • Page 38: Exercise Test Protocols

    (*) The recovery load is fixed at 25 W. 11.3 Family of Characteristics of the Braking Torque Control Range Figure 11 – 1: black: speed-independent range to DIN VDE 0750-0238 black + grey: speed-independent range of the ergoselect 1 ergometer ergoselect 1...
  • Page 39: Family Of Characteristics Of The Load Periods According To Iec 60601-1

    If operation of the ergometer continues after the indicated time interval, it is mandatory to observe the OFF and ON times. ergoselect 1...
  • Page 40: Electromagnetic Compatibility En 60601-1-2

    12 Electromagnetic Compatibility EN 60601-1-2 12 Electromagnetic Compatibility EN 60601-1-2 Warning Changes or modifications to this system not expressly approved by ergoline GmbH could cause EMC issues with RF Interference this or other equipment. Use of portable phones or other radio frequency (RF)
  • Page 41 The ergoselect 1 ergometer has no com- ponents susceptible to magnetic fields. Note: UT is the a.c. mains voltage prior to application of the test level. ergoselect 1...
  • Page 42 If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the ergoselect 1 ergometer. b) Over the frequency range from 150 kHz to 80 MHz, field strengths should be less than 3 V/m. ergoselect 1...
  • Page 43 12 Electromagnetic Compatibility EN 60601-1-2 Recommended separation distances between portable and mobile RF communications equipment and the ergoselect 1 ergometer The ergoselect 1 ergometer is intended for use in an electromagnetic environment, as specified below, in which radiated RF disturbances are controlled. The customer or the user of the ergoselect 1 ergometer can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmit- ters) and the ergoselect 1 ergometer as recommended below, according to the maximum output power of the communi-...
  • Page 44 12 Electromagnetic Compatibility EN 60601-1-2 201000551000 • Version 2023-09-18 / Rev 06 • English ergoselect 1...
  • Page 46 GmbH Lindenstraße 5 72475 Bitz Germany Tel.: +49-(0) 7431 98 94 - 0 Fax: +49-(0) 7431 98 94 - 128 e-mail: info@ergoline.com http: www.ergoline.com...