Gas fires with closed combustion system original bell-series - retro bell-series horizon bell medium / small-series - corner bell small l/r vertical bell-series - view bell-series (90 pages)
Gas fi re with closed combustion system (68 pages)
Summary of Contents for Bellfires Smart Bell 65/60 MF
Page 1
Preparation manual Smart Bell 65/60 MF Serial number: Production date:...
Page 2
Barbas Bellfires BV.This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
Dimensions of the restriction plate.....................24 Available components for the concentric flue system......25 Appliance part list........................25 Bellfires - Muelink & Grol system Ø100 - Ø150................. 26 Poujoulat - DUOGAS system Ø100 - Ø150................32 Ontop - Metaloterm US system Ø100 - Ø150................35 Jeremias/STB - H-Twin system Ø100 - Ø150................39...
• Preparation for installation This document refers to the Smart Bell 65/60 MF as 'the appliance'. This document is an essential part of your appliance.Read it carefully before you do work on the appliance. Keep it in a safe place.
Overview of the concentric flue system Overview of the concentric flue system The concentric flue system provides the appliance with combustion air and removes the flue gases from the appliance. The concentric flue system is made of these items: Item Description The concentric flue is a pipe with an inner pipe.
Only use items in the installation that are specified in this manual and the related documents. • Only use the following brands for the installation of the concentric flue system: Manufacturer system Bellfires Muelink & Grol system Poujoulat DUOGAS system Ontop Metaloterm US system Jeremias/STB (STB = Schoorsteen...
Requirements Requirements Requirements on the location • Never use combustible building materials for the fireplace. • Do not install the appliance against a flammable rear wall. • Install a non-flammable insulation plate of at least 12 mm between the appliance and a non-flammable rear wall.
Requirements Requirements on the roof and wall outlet Location of roof and wall outlets Refer to the table hereunder for explanation of the figure. Note: All the minimum distances in the table are guidelines. Consult your national and local regulations for the exact minimum distances. Smart Bell 65-60...
Page 9
Requirements Minimum separation distances for roof and wall outlet(terminal) in mm Minimum Location distance [mm] Below an opening on the same wall/roof 2000 Above an opening on the same wall/roof Horizontally to an opening on the same wall/roof Horizontally to a facing opening in a opposite wall 2000 From a roof terminal under an opening...
Requirements Requirements on the concentric flue system Caution: • Make sure that no flammable materials are located close to the flue system. The outer walls of the flue system can be 150 °C. • Make sure that the concentric flue system is in a casing. •...
Requirements 4.4.1 Possibilities for a concentric flue system with a roof outlet Rigid concentric flue systems 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm Smart Bell 65-60...
Page 12
Requirements 14,15 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
Page 13
Requirements Flexible concentric flue systems 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm Roof outlet using an flexible Ø100 mm liner in an existing lined chimney. Smart Bell 65-60...
Page 14
Requirements ≥45° 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
Page 15
Requirements 27,28,29 26,29 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing unsound lined chimney.
Requirements ≥45° 27,28,29 26,29 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
Page 17
Requirements Rigid concentric flue systems 0.16 m 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on (min. - max.) (min. - max.) the appliance is Ø100- Ø150 mm 1.0 - 2.0 m 0 - 6.5 m Smart Bell 65-60...
Technical specification Dimensions Smart Bell 65/60 with an Insert frame 50 mm and Convection fan Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 - Ø150 Roof-mounted outlet Smart Bell 65-60...
European CE-norm for gas appliances and may therefore beused only with these systems. Table 1: Approved brands Manufacturer system Bellfires Muelink & Grol system Poujoulat DUOGAS system Ontop Metaloterm US system...
Available components for the concentric flue system Bellfires - Muelink & Grol system Ø100 - Ø150 Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced flue 302289 ● ● pipe. L= 500 mm. Twin-wall balanced flue 346236 pipe.
Page 27
Available components for the concentric flue system Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced flue 302297 ● ● elbow 90°. (ribbed) Twin-wall balanced flue 346239 elbow 90°. (segment) ● ● BLACK Twin-wall balanced flue 302298 ●...
Page 28
Available components for the concentric flue system Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Vertical (roof) termina- 302295 tion kit, L= 1360 mm. ● ● ● ● ANTHRACITE Adjustable roof flash- 302212 ing. Roof pitch 20° - 45°...
Page 29
Available components for the concentric flue system Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel 302215 Wall strap. ● ● ● Set of ceiling finishing 302214 ● ● ● plates / Fire stops. Ceiling plate for transi- tion Ø100 mm / Ø150...
Page 30
Available components for the concentric flue system Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Hose clamp Ø150 mm. 304042 (Minimum 2 per con- ● ● nection) Vertical (roof) termina- tion kit, L = 610 mm.
Page 31
Available components for the concentric flue system used to extractthe flue gasses. The temperature classification of the flexible pipe must be at least T450. Smart Bell 65-60...
Available components for the concentric flue system Poujoulat - DUOGAS system Ø100 - Ø150 Poujoulat Art./ Order Description 34100403 Twin-wall balanced flue pipe, L= 250 mm. 34100404 Twin-wall balanced flue pipe. L= 450 mm. 34100405 Twin-wall balanced flue pipe. L= 950 mm. Telescopic twin-wall balanced flue pipe, L= min.
Page 33
Available components for the concentric flue system Poujoulat Art./ Order Description 34100654 Vertical (roof) termination kit, L= 140 mm . Roof flashing, suitable for a brick roof, with a roof pitch 45150171 of 15°- 30°. Roof flashing, suitable for a tiled roof, with a roof pitch 45150170 of 15°- 30°.
Page 34
Concentric pipe with inspection opening, L= 250 mm. 45150165 Roof support, (universal) Ø150 mm. 45150081 Floor support, (universal) Ø150 mm. Adapter: Bellfires Ø100-150 mm → Poujoulat DUOGAS 34100611 Ø100-150 mm(Appliance 100/150 → Poujoulat DUO- GAS 100/150) Adapter: Bellfires Ø130-200 mm → Poujoulat DUOGAS 34100614 Ø100-150 mm(Appliance 130/200 →...
Ontop - Metaloterm US system Ø100 - Ø150 Fig. Ontop Art. / Description Order No. Adapter for Bellfires appliances with Ø100-Ø150 mm USA 10 concentric connection. US 25 10 Twin-wall balanced flue pipe, L = 250 mm. US 50 10 Twin-wall balanced flue pipe.
Page 36
Available components for the concentric flue system Fig. Ontop Art. / Description Order No. USB 15 10 Twin-wall balanced flue elbow 15°. USDVC2 10 Vertical (roof) termination kit, L= 375 mm. USSR 10 Storm collar Ø150 mm. Adjustable roof flashing. Roof pitch 20° - 45°, with lead USLS 10 flashing.
Page 37
Available components for the concentric flue system Fig. Ontop Art. / Description Order No. USAB 10 Cover band, screw-fastening. USMB 10 Wall strap, adjustable. USEB 10 Fitting bracket. Set of ceiling finishing plates / Fire stops /Centering USCP 10 plates. USDQ 10 Roof support.
Page 38
Available components for the concentric flue system Fig. Ontop Art. / Description Order No. USKBS 10 Locking band, screw-fastening. USI 10 Concentric pipe with inspection panel,L= 250 mm. USEM 10 Concentric pipe with gauging orifice,L= 150 mm. USBI 10 90° concentric bend with inspection panel. USR 10 Rosette smooth Ø150 mm.
Available components for the concentric flue system Jeremias/STB - H-Twin system Ø100 - Ø150 Jeremias Fig. Art. / Order Description ATWINL Twin-wall balanced flue pipe. L= 1000 mm. 13100-150 ATWINL Twin-wall balanced flue pipe. L= 500 mm. 14100-150 ATWINL Twin-wall balanced flue pipe. L= 250 mm. 15100-150 H-TWIN Telescopic twin-wall balanced flue pipe, L= min.
Page 40
Available components for the concentric flue system Jeremias Fig. Art. / Order Description ATWIN 17 Twin-wall balanced flue elbow 30°. 100-150 ATWIN 18 Twin-wall balanced flue elbow 45°. 100-150 ATWIN Twin-wall balanced flue elbow 90°. 60100-150 ATWIN Twin-wall balanced flue elbow 90° - Short.Especially for 60F100-150 connection to a wall termination.
Page 41
Available components for the concentric flue system Jeremias Fig. Art. / Order Description ATWIN Roof termination - short with pipe,L = 300 mm, Vertical. 92100-150 ATWIN Roof termination, with pipe,L = 495 mm, Vertical, with 92pe100-15 roof flashing for existing chimney or flat roof. ATWIN Roof flashing for roof pitch 30°,with lead flashing and 45DD...
Page 42
Available components for the concentric flue system Jeremias Fig. Art. / Order Description A681100-15 Horizontal (wall) termination kit, L= 495 mm (horizontal- ly adjustable), including one set of wall spacer plates. H-TWIN Concentric T-piece with gauging orifice. Inspection 752100-150 panel with cover cap and condensation-opening. ATWIN 465 Adapter: H-TWIN Ø100-150 →...
Jeremias - TWIN-GAS system Ø100 - Ø150 Jeremias Fig. Art. / Order Description Bellfires Appliance connection / AdapterBellfires TWG163410 Ø100/150 mm → Jeremias TWIN-GAS Ø100/150 mmL 0-150 = 160 mmIncluding locking band (2x). TWG13100- Twin-wall balanced flue pipe, L = 1000 mmIncluding locking band.
Page 44
Available components for the concentric flue system Jeremias Fig. Art. / Order Description TWG50100- Telescopic twin-wall balanced flue pipe,L= min. 330 / max. 420 mmIncluding locking band. TWG16100- Twin-wall balanced flue elbow 15°. Including locking band. TWG17100- Twin-wall balanced flue elbow 30°. Including locking band.
Page 45
Available components for the concentric flue system Jeremias Fig. Art. / Order Description TWG272100 Roof termination (vertical) L= 615 mm.Including locking -150 band. Roof flashing with a roof pitch of 5° - 15°with flex. alu- TW53150 flashing and storm collar. Roof flashing with a roof pitch of 16°...
Page 46
Available components for the concentric flue system Jeremias Fig. Art. / Order Description TW45150 Locking band, screw-fastening(spare part). ALBI26150 Silicone sealing ring for outer pipe(spare part). Wall strap. Distance to the wall: WA= 50 mm. WA704150 Extension pieces for the wall strap ZUWA704L= 130 WA891130 Extension pieces for the wall strap ZUWA704L= 200 WA891200...
Page 47
Available components for the concentric flue system Jeremias Fig. Art. / Order Description Set of ceiling finishing plates / Fire stops with ventila- DA99VHL15 tion openings for a pitched roof : 0° - 30°. Set of ceiling finishing plates / Fire stopswith ventilation DA98VHL15 openings for a pitched roof : 31°...
Page 48
Available components for the concentric flue system Jeremias Fig. Art. / Order Description TWG07100- Base plate / floor support. Wall support with transverse supportType I: 350 mm DW391 - Distance to wall: WA= max. 50 mm. Wall support with transverse supportType II: 500 mm DW392 - Distance to wall: WA= 50 - 150 mm.
Modinox - PLA system Ø100 - Ø153 Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Bellfires appli- ance connec- tion: Adapter Bellfires Ø100/150 mm 2PLAMAFM100BEL ● ● → Modinox Ø100/153 mm. L= 230 mm.
Page 50
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Twin-wall bal- anced flue 2PLAELDR1001000 ● ● pipe, L= 1000 mm., INOX Twin-wall bal- anced flue 2PLAELDR1001000NO pipe, L= 1000 ●...
Page 51
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Twin-wall bal- anced flue el- 2PLACO15100 ● ● bow 15°, IN- Twin-wall bal- anced flue el- 2PLACO15100NO ● ● bow 15°, IN- OX - BLACK Vertical (roof)
Page 52
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Roof flashing, standard model, lead: 0,6mm thick, 2DIVS5PS160 ● ● for a roof pitch of 5°- 30°, with INOX cone Roof flashing, large tile mod-...
Page 53
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Horizontal (wall) termina- tion kit, with 2PLATHOR100 rosettes, L= ● ● min. 580 mm / max. 780 mm. INOX Horizontal (wall) termina- tion kit, with...
Page 54
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Rosette, IN- 2PLAROSA100BT ● ● Rosette, IN- 2PLAROSA100BTNO ● ● OX - BLACK Rosette, IN- 2PLAROSA100BTBL ● OX - WHITE Rosette with 4 2PLAROSA100 mounting...
Page 55
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Clearance 36 2PLAEPDS100 roof/floor pas- ● ● sage Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71002020 ● ●...
Page 56
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71003030 ● ● ● bottom finish- ing plate 300x300mm, INOX Adapter Modi- nox PLA →...
Page 57
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Adapter Flexi- ble pipe → Modinox PLA, with chimney 2PLAADA61002020 ● ● ● top finishing plate 200x200mm, INOX Adapter Flexi- ble pipe →...
Page 58
Available components for the concentric flue system Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Insulation kit 2PTGKIRA100 + la ISORA for ● ● pente pitched roof passage Insulation kit ISORA for pitched roof passage, roof 2PTGKIRAV100 + la and floor, in-...
Page 59
Available components for the concentric flue system Smart Bell 65-60...
Page 60
Your Bellfires dealer 01.02.2024 - 346293 - 46-002...