8600 SPA/SPAT Installation Instructions Table of Contents Table of contents 1 Technical specifications Overview Tools recommended Handing the door Closer system Instructions - parallel mount Installing drop plate and surface closer Secure soffit plate to frame: spacer block, blade stop, or narrow frame bracket...
8600 SPA/SPAT Installation Instructions Technical specifications 1 Technical specifications Overview Hold open range is from 85° to 110° with Caution: sex nuts are required for attachment optional hold open kit. of components to unreinforced doors and to wood or plastic faced composite type fire doors,...
8600 SPA/SPAT Installation Instructions Main arm 2.3 Securing main arm to closer Fig.5 45° 45° Keep arm parallel 2.3.1 Rotate pinion 45° to pre-load. 2.3.2 Attach arm PARALLEL to door. 8600 Surface Applied Closers 08280601 01-2021...
8600 SPA/SPAT Installation Instructions Adjust closing speeds Adjust hold open Adjustments Confirm closer spring size prior to making any Maximum opening angle is 100º or 180°. closing speed adjustments. Door should close in 3 to 6 seconds from 90º.
8600 SPA/SPAT Installation Instructions Adjust spring force Secure covers 3.3 Adjust spring force Fig.8 Parallel mount Door width Max door Closer size Full turns weight (lbs) Interior Exterior 2’-6” 3’ 2’6” 3’6” 3’ 4’ 3’6” Install covers Fig.9 FCSL...
Page 8
DORMA USA, Inc. T: 800-523-8483 www.dormakaba.us...