Flat arm for parallel arm mount with parallel drop bracket and drop plate (dp89) (8 pages)
Summary of Contents for Dormakaba 8600 AF/AR86 x MJ
Page 1
8600 AF/AR86 x MJ 8600 AF/AR86P x MJ Flat arm/round arm for regular and parallel mounts with mortised jamb bracket and backplate (BP89) Installation instructions 08279681 – 10-2019 | EN |...
8600 AF/AR89 P x MJ Installation Instructions Table of Contents Table of contents 1 Technical specifications Overview Tools recommended Handing the door Instructions - AF regular mount Closer system: Flat arm (AF) Installing (optional) backplate and surface closer Installing mortise jamb bracket and arms (AF) 4...
8600 AF/AR89 P x MJ Installation Instructions Technical specifications 1 Technical specifications Overview Caution: sex nuts are required for attachment Know the swing of the door which is being of components to unreinforced doors and to installed prior to installation.
8600 AF/AR89 P x MJ Installation Instructions AF regular mount Instructions - AF regular mount 2.1 Closer system: Flat arm (AF) Fig.2 1. Door closer 2. Connecting arm (flat) 3. Bar and shoe 4. Dust cap 5. Flat head combo screws 6.
8600 AF/AR89 P x MJ Installation Instructions AR regular mount Instructions - AR regular mount 3.1 Closer system: Round arm (AR) Fig.5 1. Door closer 2. Connecting arm (round) 3. Bar and shoe 4. Dust cap 5. Flat head combo screws 6.
8600 AF/AR89 P x MJ Installation Instructions AF parallel mount Instructions - AF parallel mount 4.1 Closer system: Flat arm (AF) Fig.8 1. Door closer 2. Connecting arm (flat) 3. Bar and shoe (not shown) 4. Dust cap 5. Flat head combo screws 6.
8600 AF/AR89 P x MJ Installation Instructions AR parallel mount Instructions - AR parallel mount 5.1 Closer system: Round arm (AR) Fig.11 1. Door closer 2. Connecting arm (round) 3. Bar and shoe 4. Dust cap 5. Flat head combo screws 6.
8600 AF/AR89 P x MJ Installation Instructions Adjust closing speeds Adjustments Confirm closer spring size prior to making any Maximum opening angle is 180º. closing speed adjustments. Door should close in 3 to 6 seconds from 90º. Do not back valve heads out beyond closer casting.
8600 AF/AR89 P x MJ Installation Instructions Adjust spring force Secure covers 6.2 Adjust spring force Fig.15 Increase Decrease Regular mount Door width Max door Closer size Full turns weight (lbs) Interior Exterior 2’6” ---- 3’ 2’6” 3’6” 3’...
Page 10
DORMA USA, Inc. T: 800-523-8483 www.dormakaba.us...