Alarm Events; The Default Alarm Settings - 3Com SuperStack 3C17300 Implementation Manual

4200 series
Hide thumbs Also See for SuperStack 3C17300:
Table of Contents

Advertisement

60
C
7: S
HAPTER
TATUS

Alarm Events

The Default Alarm
Settings
M
S
ONITORING AND
TATISTICS
You can define up to 200 alarms for the Switch. The events that you can
define for each alarm and their resulting actions are listed in
Table 5 Alarm Events
Event
No action
Notify only
Notify and filter port
Notify and disable port
Notify and enable port
Disable port
Enable port
Notify and unfilter port
System started
Software Upgrade report
A new or initialized Switch has the following alarm(s) defined for each
port:
Percentage of errors over one minute
The default values and actions for each of these alarms are given in
Table
6.
Table 6 Values for the default alarm(s)
Statistic
Broadcast
bandwidth used
Action
Send Trap.
Send Trap. Block broadcast and multicast
traffic on the port. Recovers with the unfilter
port event.
Send Trap. Turn port off.
Send Trap. Turn port on.
Turn port off.
Turn port on.
Send Trap. Stop blocking broadcast and
multicast traffic on the port.
High Threshold
Value: 20%
Action: Notify and filter
Table
Low Threshold
Recovery
Value: 10%
Action: Notify and unfilter
5.
Period
30 secs