WARRANTY
This range of product is covered by a limited 2 year warranty against component
failure or faulty workmanship from the date of installation.
A faulty unit should be returned in the first instance to the dealer from which
the unit was purchased.
Damage to the unit due to misuse, power surges, lightning strikes or
installation that is not in accordance with the manufacturer's instruction
may void the warranty.
Warranty does not cover travel costs to or from installation site.
If the power cord is damaged, do not use the controller; return the unit to the
supplier for repair.
Customer Record. (To be retained by the customer)
Dealer/Installer Name _____________________________________
Serial Number
_____________________________________
Date Installed
_____________________________________
For service assistance phone 1300 130 693
H3A_Dontek_Instructions_rB1.doc
P.O. Box 239
Bayswater
Victoria 3153
www.dontek.com.au
H3A Controller
Description of Operation: The H3A Controller is designed to switch a
240Vac pump rated to 10 Amps 2400 watts*
relay contact rated to 5A @ 24Vac. The H3A switches on the pump, the
heater is turned on dependant on the heating times and temperature
limits as set on the H3A.
The H3A to operate to meet its own heating times & temperature limits.
If the temperature limit is reached the unit will stop the pump and start
an adjustable sample wait period.
The H3RO is fitted with an LCD screen which displays
or heater is on or off, when it displays 'cooldown' the pump is running
with the heater switched off.
Installation Instructions:
Controller Mounting: Find a suitable location to mount the control box.
Ideally as with all pool equipment it should be installed out of direct
weather and no closer than 3 meters from the water's edge. Lift up the
two mounting tabs and use two appropriate screws to mount the control
box to the wall, keeping in mind that the power cable is 1.8m long and
should be plugged directly into a general power outlet, not into an
extension lead.
Pump: The filtration pump plugs into the 240V outlet beneath the
controller (marked PUMP on the controller face plate).
6
and control a heater via a
whether
the pump

Advertisement

loading
Need help?

Need help?

Do you have a question about the H3A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dontek H3A

  • Page 1 240Vac pump rated to 10 Amps 2400 watts* and control a heater via a relay contact rated to 5A @ 24Vac. The H3A switches on the pump, the A faulty unit should be returned in the first instance to the dealer from which heater is turned on dependant on the heating times and temperature the unit was purchased.
  • Page 2 It is recommended that a 14.5mm hole be drilled in the manufacturer for correct interlocking procedure, see picture for typical PVC pipe, this can be carried out using a Dontek PD01 grinding drill or a connection set-up. Note damage caused by incorrect connections will small pilot hole can be drilled and a 14.0mm drill-bit used spinning in a...
  • Page 3 NOTES: H3A Operating Instructions: 1. If a sensor fault is detected the controller will display the reason for the failure. For filtration time-clock operation refer to the operating instructions of 2. Should power be interrupted for any reason, the controller will the chlorinator.
  • Page 4 1)CLOCK Run-On time (heater cool-down): Set the time of day in 24 hour format, note there is an AM/PM indication When the heater switches off the pump is locked to run for a time period to avoid incorrect settings. Seconds are automatically set to zero. without heating, this is to cool down the heater and prevent damage to the heater (and pipes) from heat soak.