Page 1
DF700A/DF710A/DF750A-U2 DF750A/DF760A DF750AK/DF760AK User Manual Published: 2023/11/13 Version 1.1 TM970246 PROMAG ® GIGA-TMS INC.
Page 2
GIGA-TMS INC makes no responsibility to update such materials In no event shall GIGA-TMS INC be liable to you or any third party for any special incidental, indirect or consequential damages of any kind, or any damages whatsoever, including, without limitation, those resulting from loss of use, data or profits, whether or not GIGA-TMS INC has been advised of the possibility of damage, and on any theory of liability, arising out of or in connection with the use of the software.
Page 3
GIGA-TMS’s original packages, and for goods modified, altered, or treated without authorization by GIGA-TMS. Service may be obtained by delivering the product during the warranty period to GIGA-TMS (8F No. 31 Lane 169, Kang Ning Street, Hsi Chih Dist New Taipei City, Taiwan). If this product is delivered by mail or by an equivalent shipping carrier, the customer agrees to insure the product or assume the risk of loss or damage in transit, to prepay shipping charges to the warranty service location, and to use the original shipping container or equivalent.
Introduction Introduction General DESFire Reader is a user configurable MIFARE sector data reader. It can be configured to read MIFARE card with MAD1/MAD2/MAD3 standard in a MIFARE application open system, or can be configured to read the user-defined sector data (Non-MAD) in a user defined closed system. Output interface can be configured as an RS232 output or Wiegand output.
Introduction ™ MIFARE Application Directory (MAD) Support DF7XXA supports the MAD format card, the MAD (MIFARE application directory) standard proposes the introduction of common data structures for card application directory entries. DF7XXA should take advantage of this feature using those sector pointers instead of physical sector number. Auto Mode DF7XXA reader will search the AID from Mifare application directory (MAD), and then get a correctly...
Hardware Features Hardware Features DF700A/DF710A Series Wire Assignment DF700A-00/DF710A-00 Color Symbol Description Power Input : DC 9V~24V Black Power Ground White DATA 1 Wiegand Data 1 Signal / ABA-TK2 Clock (Strobe) Green DATA 0 Wiegand Data 0 Signal / ABA-TK2 Data Yellow DF700A-00: RS232 TXD (To Host RXD) DF710A-00:RS485+...
Page 9
Hardware Features Orange ABA TK2 Card Present Brown LED/BUZZER IN External LED/BUZZER Control DF710A-U2 Color Symbol Description Power Input : DC 9V~24V Black Power Ground White DATA 1 Wiegand Data 1 Signal Green DATA 0 Wiegand Data 0 Signal Yellow RS485+ Blue RS485-...
Hardware Features Part Numbers Device numbering scheme is as follows: DF75 0A - 00 00: Standard U2: Fermax Reader 0: RS232 interface 1: RS485 interface ‘ Examples of valid part numbers: Part Number Description DF700A-00 DF700A reader with RS232 communication interface. DF710A-00 DF710A reader with RS485 communication interface.
Page 11
Hardware Features RF Frequency 13.56 MHz Environment Operating Temperature 0C ~ +50C Storage Temperature -10C ~ +60C Humidity 10 ~ 90 relative Dimensions Width 46.5 mm Height 82.5 mm Depth 25.0 mm DF7XXA User Manual V1.1...
Hardware Features DF750A/DF760A/DF750AK/DF760AK Series DF750A/DF760A series DF750AK/DF760AK Series Wire Assignment Color Symbol Description Power Input : DC 9V~24V Black Power Ground White DATA 1 Wiegand Data 1 Signal / ABA-TK2 Clock (Strobe) Green DATA 0 Wiegand Data 0 Signal / ABA-TK2 Data Yellow DF750A/DF750AK: RS232 TXD (To Host RXD) DF760A/DF760AK: RS485+...
Page 13
Hardware Features DF7XXA User Manual V1.1...
Hardware Features Part Numbers Device numbering scheme is as follows: DF75 0A - 00 00: Standard K: with keypad BLANK: w/o Keypad 5: RS232 interface 6: RS485 interface ‘ Examples of valid part numbers: Part Number Description DF750A-00 DF750A reader doesn’t have keypad with RS232 communication interface. DF760AK-00 DF760A reader has keypad with RS485 communication interface.
Device Operation Device Operation Preparation To configure DF7XXA(K), you need to connect the reader to the reader-kit first below (refer to wire assignment): DF700A MF700 Reader-Kit MF700KIT ORANGE BLACK WHITE WAS-T0029 YELLOW BLUE GREEN BROWN " " " " Above housing is for reference only. 9VDC DF710A The following is the example of using USB485A-00 with DF710A.
Page 17
Device Operation Note: Reader-kit and USB485A-00 are connection tool kit. They are optional items for purchasing. DF7XXA User Manual V1.1...
Device Operation Setting up Reader – Using Mifare/DESFire Reader Utility Install Mifare/DESFire Reader Utility software in your PC and connect the reader to PC. Please check the connection of PC-to-reader is correctly. Note: Download the Mifare/DESFire Reader Utility setup file from the link: http://ftp.gigatms.com.tw/disks/disk5238/.
Device Operation Mifare Settings MAD-AID (default=4703) ™ MAD Application Identifier number is authorized and assigned by Mifare.net upon the customer’s request for registered Application Identifier in a Mifare application open system (AID:0000h~FFFFh).Or it is also possible for the user to define the AID himself for the application in user defined closed system without registering into MAD group.
Device Operation Example: If your card data is in the grey grid of sector, you have to set the "Offset" = 17, and set the "Length"= 20. AID Sector (or Non-MAD Sector) Block 0 Block 1 Block 2 DESFire Settings MAD-AID (default=F47030) ™...
Device Operation The Data file will depend on the value to output data. The Value file will be sent the value out. The Record file will be sent the latest record data. Access Key No/Value (default=0 / 00000000000000000000000000000000) Key must be the same as the Read or Read/Write KEY of the card issued. This means DF7XXA only can read the data on the card with the same key.
Page 22
Device Operation ⚫ CSN Only Read card CSN (card ID) only. Output Modes (default=Once) ⚫ Once Read card sector data only. If any error occurs (ex: App. key incorrect.), the reader will represent "Card Invalid" status. ⚫ Continue Keeping sending data (or CSN) to host till card remove. Only for Mifare card. Keypad Settings These keypad settings are applied only for reader has keypad (DF750AK/DF760AK).
Device Operation LED/Buzzer Settings DF7XX supports LED/Alarm configure. Set the LED/Buzzer to indicate the system status for end-user. Enable RS232 Command Set Control Enable this setting if you need to control LED/Buzzer by software command set. Note: This function is only available for the RS232 communication settings are (19200, N, 8, 1). DF7XXA User Manual V1.1...
Page 25
Device Operation DF7XXA User Manual V1.1...
Page 26
Device Operation RS232 LED/Buzzer command set frame STX J NUMBER (0~9) 02h 4Ah 30h~39h Command Table NUMBER Descriptions 0 (30h) All LED Off, Buzzer Off 1 (31h) Green LED ON 2 (32h) Green LED OFF 3 (33h) Red LED ON 4 (34h) Red LED OFF 5 (35h)
Page 27
Device Operation Read Idle Show LED color after power on or idle state. Brown Wire = PULSE (Internal: Card is Valid) Show LED color and beeps to indicate the end-user when brown wire inputted pulse signal, or card was passed by reader. Remark: This setting is enabled when “Brown Wire Active Level”...
Device Operation Wiegand Settings Add Reader ID (default=Disable) Set Wiegand output data to include the Reader ID when it is checked. Custom Preamble (default=Disable) Set the Wiegand output data to include prem Add Reader ID (default=Disable) Set Wiegand output data to include the Reader ID when it is checked. Custom Preamble (default=Disable) Set the Wiegand output data to include preamble code when it is enabled.
Device Operation Alive Event is reserved. ABA-TK2 Settings Number of Digital (default=10) Set the number of digital codes for TK2 output. Add Reader ID (default=Disable) Add Reader ID into TK2 data. Output Data Order (default=MSB First) Set the TK2 data sequence order. Data Conversion (default=BIN to DEC) Select card data format to convert.
Device Operation RS232/485 Settings Baud rate (default=9600) The working range can be set from 2400 to 57600 (depends on the device). Heart beat (default=disabled) Click to select the interval time of periodically sending the heart beat data to host via RS232/485 interface. The heart beat data format is: ‘E’...
Page 31
Device Operation Data Sequence (default=MSB first) The output data sequence order can be set to "LSB" first or "MSB" first. Package (default=Header (02h) + CR + LF + Trailer (03h)) To set a packet which includes the “Header”, “Reader ID”, “Data Length”, “CR”, “LF” and “Trailer”. (Header: 00h~FFh, Trailer: 00h~FFh).
Device Operation Configured Card Settings Configured Card Enabled (default=Enable) Can allow your reader change configuration by Mifare Card. Key (default=000000000000) To be the Mifare Key A for allowed the configured card. DF7XXA User Manual V1.1...
Device Operation Make a Configured Card DF7XX supports updating the reader by reading Configured Card. This function is specially using when stand alone system. The following steps guide you how to make a configured card. Step 1: Configure the reader. Click to select Configured Card Enabled, and then click Update Reader.
Page 34
Device Operation Remark: The corresponding series are “DF700/DF750 Series”. Step 3: Configure all settings as normal. Click Configure Card. DF7XXA User Manual V1.1...
Page 35
Device Operation Step 4: Put a Mifare card in the PCR310 cassette. Enter “MAD Admin Key” and “Configured Key” (which has been updated to the corresponding reader). Click Create. Step 5: Take this card to approach Remark: If the reader you use is the one with the the reader for configured keypad, you need to press *00# to enter the settings.
Device Operation Data Output Reader Test After reader’s configurations have been updated success, you can use Test function to check reader’s configurations have been correctly stored. Click to clear the output data, or double click the output area. Click to re-connect Available COM port.
Device Operation Test Read Card After Updating The following steps guide you how to test read card. After set configurations in the Reader Utility software, you can click Update Reader to update the currently configurations to the reader. Or, click Test to update configurations and verify output data. Take an issued Mifare card and approach it to the reader, You can see the output data on “Reader Test”...
Page 38
Device Operation Remark: (1) When using reader-kit to test Wiegand (or TK2) signal, this test may be failed if the processor of computer is too slow. (2) When using reader-kit to test Wiegand (or TK2) signal, you need to connect to the physical COM port. DF7XXA User Manual V1.1...
Technical Support Technical Support http://ftp.gigatms.com.tw/disks/disk5238/ Is your Download Center where you can: Find apps and source code. View manuals and the knowledge base. Download the latest firmware and software. DF7XXA User Manual V1.1...
Appendix Appendix Wiegand Interface The Data 1 and Data 0 signals are held at a logic high level unit, the reader is ready to send a data stream. The reader places data as asynchronous low-going pulses on the Data 1 or Data 0 lines to transmit the data stream to Host.
Page 44
Appendix Example of connecting Wiegand wires (the pull high resister must >= 10K Ohm) HOST/Terminal 5VDC Pull high resistor 7.5~24VDC >=10K Ohm Reader (Red) Data 1 (White) Data 0 (Green) (Black) Optional: External LED/Buzzer Control (Brown) DF7XXA User Manual V1.1...
Appendix ABA-TK2 Interface Example of the timing for card present, clock (strobe) and data /CARD PRESENT Leading Zero Data Trailing Zero /DATA /STROBE (CLOCK) 0 . . . 0 1 . . . STROBE Width Approximately 25~50% Of Bit Time Bit Time 40IPS (min:280us, typ:330us, max:480us) DATA The data signal is valid while the clock is low.
Page 46
Appendix Example of connecting ABA TK2 wires HOST/Terminal 7.5~24VDC (Red) Reader Card Present (Orange) Clock (White) Data (Green) (Black) Optional: External LED/Buzzer Control (Brown) DF7XXA User Manual V1.1...
Appendix External LED/Buzzer Control DF7XXA supports the external LED/Buzzer control for Terminal (or Host) to prompt end-user the card data is invalid or valid. Use Brown wire to control the LED/Buzzer of DF7XX. Examples (Active High) (1) Show External Invalid Status Data Output Alarm Control (Brown) Min 100 ms...
Caution Caution CAUTION: The crossed out wheeled bin label that can be found on your product indicates that this product should not be disposed of via the normal household waste stream. To prevent possible harm to the environment or human health please separate this product from other waste streams to en-sure that it can be recycled in an environmentally sound manner.
Update History Update History 2023/8/21 V1.0 ⚫ Added DF750A/DF750AK/DF760A/DF760AK readers. 2023/8/21 V1.0 ⚫ Original Release DF7XXA User Manual V1.1...