FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 3
GIGA-TMS INC makes no responsibility to update such materials In no event shall GIGA-TMS INC be liable to you or any third party for any special incidental, indirect or consequential damages of any kind, or any damages whatsoever, including, without limitation, those resulting from loss of use, data or profits, whether or not GIGA-TMS INC has been advised of the possibility of damage, and on any theory of liability, arising out of or in connection with the use of the software.
Page 4
GIGA-TMS’s original packages, and for goods modified, altered, or treated without authorization by GIGA-TMS. Service may be obtained by delivering the product during the warranty period to GIGA-TMS (8F No. 31 Lane 169, Kang Ning Street, Hsi Chih Dist New Taipei City, Taiwan). If this product is delivered by mail or by an equivalent shipping carrier, the customer agrees to insure the product or assume the risk of loss or damage in transit, to prepay shipping charges to the warranty service location, and to use the original shipping container or equivalent.
Introduction Introduction General DESFire Reader is a user configurable MIFARE sector data reader. It can be configured to read MIFARE card with MAD1/MAD2/MAD3 standard in a MIFARE application open system, or can be configured to read the user-defined sector data (Non-MAD) in a user defined closed system. Output interface can be configured as an RS232 output or Wiegand output.
Hardware Features DF710A-U2 Color Symbol Description Power Input : DC 9V~24V Black Power Ground White DATA 1 Wiegand Data 1 Signal Green DATA 0 Wiegand Data 0 Signal Yellow RS485+ Blue RS485- Orange Digital Input 1 (Door Sensor) Brown Digital Input 2 (Exit Button) Purple Digital Output 1 Gray...
Hardware Features Part Numbers Device numbering scheme is as follows: DF75 0A - 00 00: Standard U2: Fermax Reader 0: RS232 interface 1: RS485 interface ‘ Examples of valid part numbers: Part Number Description DF700A-00 DF700A reader with RS232 communication interface. DF710A-00 DF710A reader with RS485 communication interface.
Page 12
Hardware Features RF Frequency 13.56 MHz Environment Operating Temperature 0C ~ +50C Storage Temperature -10C ~ +60C Humidity 10 ~ 90 relative Dimensions Width 46.5 mm Height 82.5 mm Depth 25.0 mm DF700A User Manual V1.0...
when the card is not issued by "Mifare Card Issuer" software. And you must set the "Offset" (Max 255, and base from zero) from the beginning of sector and set your data "Length" (Max 240).
Example: If your card data is in the grey grid of sector, you have to set the "Offset" = 17, and set the "Length"= 20. AID Sector (or Non-MAD Sector) Block 0 Block 1 Block 2...
Page 20
If “Enable Two Wires Control LED” checkbox is checked, the external LED/Buzzer control with high/low level control will be disabled...
Page 21
Device Operation Read Idle Show LED color after power on or idle state. Brown Wire = PULSE (Internal: Card is Valid) Show LED color and beeps to indicate the end-user when brown wire inputted pulse signal, or card was passed by reader. Remark: This setting is enabled when “Brown Wire Active Level”...
Page 25
Device Operation Data Sequence (default=MSB first) The output data sequence order can be set to "LSB" first or "MSB" first. Package (default=Header (02h) + CR + LF + Trailer (03h)) To set a packet which includes the “Header”, “Reader ID”, “Data Length”, “CR”, “LF” and “Trailer”. (Header: 00h~FFh, Trailer: 00h~FFh).
Device Operation Data Output Reader Test After reader’s configurations have been updated success, you can use Test function to check reader’s configurations have been correctly stored. Use to “decode with parity” when Wiegand interface not with parity. Click to clear the output data, or double click the output area.
Device Operation Test Read Card After Updating The following steps guide you how to test read card. After set configurations in the Reader Utility software, you can click Update Reader to update the currently configurations to the reader. Or, click Test to update configurations and verify output data. Take an issued Mifare card and approach it to the reader, You can see the output data on “Reader Test”...
Technical Support Technical Support http://ftp.gigatms.com.tw/disks/disk5238/ Is your Download Center where you can Find apps and source code View manuals and the knowledge base Download the latest firmware and software DF700A User Manual V1.0...
Appendix Appendix Wiegand Interface The Data 1 and Data 0 signals are held at a logic high level unit, the reader is ready to send a data stream. The reader places data as asynchronous low-going pulses on the Data 1 or Data 0 lines to transmit the data stream to Host.
Caution Caution CAUTION: The crossed out wheeled bin label that can be found on your product indicates that this product should not be disposed of via the normal household waste stream. To prevent possible harm to the environment or human health please separate this product from other waste streams to en-sure that it can be recycled in an environmentally sound manner.