5.
Remove the fan modules.
6.
Remove the fan cage. Pressing the locking tabs at both ends of the fan cage, lift the fan cage to
remove it out of the chassis.
7.
Disconnect cables from the backplane.
8.
Remove the drive backplane. Loosen the captive screws that secure the backplane, and then
lift the backplane out of the chassis.
Installing a drive backplane
1.
Install a drive backplane. Place the backplane in the slot and then fasten the captive screws.
2.
Connect cables to the drive backplane.
3.
Install the fan cage.
4.
Install the fan modules.
5.
Install the access panel:
a. Place the access panel onto the server.
b. Slide the access panel to the server front and close the locking lever. The access panel
snaps into place.
6.
Install the removed drives.
7.
Rack-mount the server. For more information, see
8.
Connect the power cord. For more information, see
9.
Power on the server. For more information, see
Installing a rear drive cage
Prerequisites
Take the following ESD prevention measures:
•
Wear antistatic clothing.
•
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
•
Do not wear any conductive objects, such as jewelry or watches.
•
When you replace a component, examine the slot and connector for damages. Make sure the
pins are not damaged (bent for example) and do not contain any foreign objects.
Procedure
1.
Power off the server. For more information, see
2.
Remove the server from the rack. For more information, see
3.
Remove the access panel:
a. Press the button on the locking lever and then lift the locking lever.
The access panel automatically slides to the server rear.
b. Lift the access panel to remove it from the server.
4.
Remove the PCIe riser card blank. Lift the blank to remove it from the chassis.
5.
For a 2SFF UniBay drive cage, install a bracket:
a. Align the guide pin on the bracket with the notch in the chassis.
b. Place the bracket in the chassis.
c. Use screws to secure the bracket.
6.
Install the rear drive cage:
"Rack-mounting the
"Connecting the power
"Powering on the
"Powering off the
"Removing the server from a
86
server."
cord."
server."
server."
rack."